{"id":{"repo_id":"epfl","oai_identifier":"oai:infoscience.epfl.ch:20.500.14299/241659"},"canonical_url":"https://search.ndltd.org/etd/epfl/oai:infoscience.epfl.ch:20.500.14299/241659","repository":{"repo_id":"epfl","name":"EPFL","base_url":"https://infoscience.epfl.ch/server/oai/openaire4"},"display":{"title":"Design and implementation of a soft X-ray absorption spectroscopy setup for liquid samples at SwissFEL","abstract":"This thesis presents the development and implementation of a novel experimental setup for time-resolved soft X-ray absorption spectroscopy on liquid samples at SwissFEL. The setup allows the investigation of important absorption edges, such as the nitrogen K-edge, the oxygen K-edge and transition metal L-edges, for site-selective studies of a sample in a single experiment. A key feature of the setup is a novel catcher design in combination with a gas-squeezing liquid jet. This allows the reliable use of liquid sheets of adjustable thickness in a high vacuum environment adhering to the requirements of experiments at free-electron laser sources. The setup can be operated with small sample volumes of 50 mL , and recircula- tion of the sample is possible. Test experiments at a synchrotron light source provided first valence absorption spectra of liquid water. At the X-ray free-electron laser, proof-of-concept experiments yielded absorption spectra of water around the oxygen K-edge and the transient absorption of a 30 mM aqueous iron(II)-trisbipyridine solution around the nitrogen K-edge and the iron L3-edge. Different modalities for X-ray absorption measurements with intense pulses from a free-electron laser were compared and recommendations depending on the sample conditions were formulated.","abstract_html":"This thesis presents the development and implementation of a novel experimental setup for time-resolved soft X-ray absorption spectroscopy on liquid samples at SwissFEL. The setup allows the investigation of important absorption edges, such as the nitrogen K-edge, the oxygen K-edge and transition metal L-edges, for site-selective studies of a sample in a single experiment. A key feature of the setup is a novel catcher design in combination with a gas-squeezing liquid jet. This allows the reliable use of liquid sheets of adjustable thickness in a high vacuum environment adhering to the requirements of experiments at free-electron laser sources. The setup can be operated with small sample volumes of 50 mL , and recircula- tion of the sample is possible. Test experiments at a synchrotron light source provided first valence absorption spectra of liquid water. At the X-ray free-electron laser, proof-of-concept experiments yielded absorption spectra of water around the oxygen K-edge and the transient absorption of a 30 mM aqueous iron(II)-trisbipyridine solution around the nitrogen K-edge and the iron L3-edge. Different modalities for X-ray absorption measurements with intense pulses from a free-electron laser were compared and recommendations depending on the sample conditions were formulated.","abstract_has_math":false,"creators":["Knurr, Jonas"],"institution":"EPFL","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Bostedt, Christoph"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-10-21T13:59:28Z","date_published":"2024-10-21T13:59:28Z","updated_at":"2026-11-26T13:50:29Z","subjects":["X-ray absorption","time-resolved","liquid jet","free-electron laser"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://infoscience.epfl.ch/handle/20.500.14299/241659"],"render_values":[{"text":"https://infoscience.epfl.ch/handle/20.500.14299/241659","href":"https://infoscience.epfl.ch/handle/20.500.14299/241659","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.5075/epfl-thesis-10809","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.5075/epfl-thesis-10809","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aepfl%3Aoai%3Ainfoscience.epfl.ch%3A20.500.14299%2F241659","prefix":"oai_dc"},"source_record":{"url":"https://infoscience.epfl.ch/server/oai/openaire4?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ainfoscience.epfl.ch%3A20.500.14299%2F241659","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Bostedt, Christoph"]},{"key":"dc:creator","label":"Author","values":["Knurr, Jonas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-10-21T13:59:28Z","2024-10-21","2024","2026-08-12T19:53:40.716967Z"]},{"key":"dc:publisher","label":"Institution","values":["EPFL","Lausanne"]},{"key":"dc:type","label":"Dc Type","values":["doctoral thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["X-ray absorption","time-resolved","liquid jet","free-electron laser"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.5075/epfl-thesis-10809","https://infoscience.epfl.ch/handle/20.500.14299/241659"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This thesis presents the development and implementation of a novel experimental setup for time-resolved soft X-ray absorption spectroscopy on liquid samples at SwissFEL. The setup allows the investigation of important absorption edges, such as the nitrogen K-edge, the oxygen K-edge and transition metal L-edges, for site-selective studies of a sample in a single experiment. A key feature of the setup is a novel catcher design in combination with a gas-squeezing liquid jet. This allows the reliable use of liquid sheets of adjustable thickness in a high vacuum environment adhering to the requirements of experiments at free-electron laser sources. The setup can be operated with small sample volumes of 50 mL , and recircula- tion of the sample is possible. Test experiments at a synchrotron light source provided first valence absorption spectra of liquid water. At the X-ray free-electron laser, proof-of-concept experiments yielded absorption spectra of water around the oxygen K-edge and the transient absorption of a 30 mM aqueous iron(II)-trisbipyridine solution around the nitrogen K-edge and the iron L3-edge. Different modalities for X-ray absorption measurements with intense pulses from a free-electron laser were compared and recommendations depending on the sample conditions were formulated.","LUXS"]},{"key":"dc:source","label":"Dc Source","values":["THESIS"]},{"key":"dc:title","label":"Title","values":["Design and implementation of a soft X-ray absorption spectroscopy setup for liquid samples at SwissFEL"]}]}],"canonical_facts":{"dc:contributor":["Bostedt, Christoph"],"dc:creator":["Knurr, Jonas"],"dc:date":["2024-10-21T13:59:28Z","2024-10-21","2024","2026-08-12T19:53:40.716967Z"],"dc:description":["This thesis presents the development and implementation of a novel experimental setup for time-resolved soft X-ray absorption spectroscopy on liquid samples at SwissFEL. The setup allows the investigation of important absorption edges, such as the nitrogen K-edge, the oxygen K-edge and transition metal L-edges, for site-selective studies of a sample in a single experiment. A key feature of the setup is a novel catcher design in combination with a gas-squeezing liquid jet. This allows the reliable use of liquid sheets of adjustable thickness in a high vacuum environment adhering to the requirements of experiments at free-electron laser sources. The setup can be operated with small sample volumes of 50 mL , and recircula- tion of the sample is possible. Test experiments at a synchrotron light source provided first valence absorption spectra of liquid water. At the X-ray free-electron laser, proof-of-concept experiments yielded absorption spectra of water around the oxygen K-edge and the transient absorption of a 30 mM aqueous iron(II)-trisbipyridine solution around the nitrogen K-edge and the iron L3-edge. Different modalities for X-ray absorption measurements with intense pulses from a free-electron laser were compared and recommendations depending on the sample conditions were formulated.","LUXS"],"dc:identifier":["10.5075/epfl-thesis-10809","https://infoscience.epfl.ch/handle/20.500.14299/241659"],"dc:language":["eng"],"dc:publisher":["EPFL","Lausanne"],"dc:source":["THESIS"],"dc:subject":["X-ray absorption","time-resolved","liquid jet","free-electron laser"],"dc:title":["Design and implementation of a soft X-ray absorption spectroscopy setup for liquid samples at SwissFEL"],"dc:type":["doctoral thesis"]},"updated_at":"2026-11-26T13:50:29Z"}