{"id":{"repo_id":"epfl","oai_identifier":"oai:infoscience.epfl.ch:20.500.14299/269383"},"canonical_url":"https://search.ndltd.org/etd/epfl/oai:infoscience.epfl.ch:20.500.14299/269383","repository":{"repo_id":"epfl","name":"EPFL","base_url":"https://infoscience.epfl.ch/server/oai/openaire4"},"display":{"title":"Dependable Data-driven Control Strategies for Energy-Efficient Building Systems","abstract":"Model predictive control (MPC) can reduce building energy use and support demand-side flexibility. However, in practice, deployment is limited by model-commissioning effort, varying building dynamics, and prediction uncertainties. Standard MPC formulations also do not directly specify realized comfort-violation rate or severity. This thesis develops dependable data-driven control strategies for energy-efficient building systems. The first part develops two complementary methods for low-commissioning data-driven predictive control based on Willems' Fundamental Lemma. An efficient recursive data-enabled predictive control (DeePC) formulation keeps the computational cost fixed as operational data accumulate, while a physics-based filter enforces prescribed physical rules on predictions from noisy measurements. The second part tests the integration and sustained deployment of DeePC in real-world building control. An adaptive data-driven prediction layer is embedded in a bi-level DeePC hierarchy for secondary frequency control in a simulated Swiss ancillary-service market, where scenario-based day-ahead optimization and convex robust predictive control handle bidding and operational uncertainties. In a 52-day experiment at the Polydome, an occupied lecture hall on the EPFL campus, the controller coordinated a heat pump and a battery emulator. In selected periods with similar weather, it achieved about 24% lower average daily operating costs relative to two baseline scenarios. The third part addresses closed-loop comfort management through violation rate and severity. A disturbance-adaptive MPC framework establishes guarantees on average violation rate and is extended to data-driven building control. In eight Polydome field scenarios covering 76 days, the controller was tested with prescribed violation-rate bounds of 2.5%, 5%, and 10%. At the 5% bound, it reduced energy consumption by 20.5% relative to the default controller under similar weather conditions. A Kelvin-hour-budget MPC then shifts the prescribed quantity from violation rate to severity. It was evaluated through high-fidelity simulations and three six-day field deployments in an occupied home.","abstract_html":"Model predictive control (MPC) can reduce building energy use and support demand-side flexibility. However, in practice, deployment is limited by model-commissioning effort, varying building dynamics, and prediction uncertainties. Standard MPC formulations also do not directly specify realized comfort-violation rate or severity. This thesis develops dependable data-driven control strategies for energy-efficient building systems. The first part develops two complementary methods for low-commissioning data-driven predictive control based on Willems&#x27; Fundamental Lemma. An efficient recursive data-enabled predictive control (DeePC) formulation keeps the computational cost fixed as operational data accumulate, while a physics-based filter enforces prescribed physical rules on predictions from noisy measurements. The second part tests the integration and sustained deployment of DeePC in real-world building control. An adaptive data-driven prediction layer is embedded in a bi-level DeePC hierarchy for secondary frequency control in a simulated Swiss ancillary-service market, where scenario-based day-ahead optimization and convex robust predictive control handle bidding and operational uncertainties. In a 52-day experiment at the Polydome, an occupied lecture hall on the EPFL campus, the controller coordinated a heat pump and a battery emulator. In selected periods with similar weather, it achieved about 24% lower average daily operating costs relative to two baseline scenarios. The third part addresses closed-loop comfort management through violation rate and severity. A disturbance-adaptive MPC framework establishes guarantees on average violation rate and is extended to data-driven building control. In eight Polydome field scenarios covering 76 days, the controller was tested with prescribed violation-rate bounds of 2.5%, 5%, and 10%. At the 5% bound, it reduced energy consumption by 20.5% relative to the default controller under similar weather conditions. A Kelvin-hour-budget MPC then shifts the prescribed quantity from violation rate to severity. It was evaluated through high-fidelity simulations and three six-day field deployments in an occupied home.","abstract_has_math":false,"creators":["Shi, Jicheng"],"institution":"EPFL","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Jones, Colin Neil"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-11-16T15:08:22Z","date_published":"2026-11-16T15:08:22Z","updated_at":"2026-11-26T13:52:54Z","subjects":["model predictive control","data-driven predictive control","energy-efficient buildings","demand response","robust model predictive control","thermal comfort management","building automation"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://infoscience.epfl.ch/handle/20.500.14299/269383"],"render_values":[{"text":"https://infoscience.epfl.ch/handle/20.500.14299/269383","href":"https://infoscience.epfl.ch/handle/20.500.14299/269383","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.5075/epfl-thesis-11692","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.5075/epfl-thesis-11692","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aepfl%3Aoai%3Ainfoscience.epfl.ch%3A20.500.14299%2F269383","prefix":"oai_dc"},"source_record":{"url":"https://infoscience.epfl.ch/server/oai/openaire4?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ainfoscience.epfl.ch%3A20.500.14299%2F269383","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Jones, Colin Neil"]},{"key":"dc:creator","label":"Author","values":["Shi, Jicheng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-11-16T15:08:22Z","2026-11-16","2026","2026-11-17T12:30:48.792975Z"]},{"key":"dc:publisher","label":"Institution","values":["EPFL","Lausanne"]},{"key":"dc:type","label":"Dc Type","values":["doctoral thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["model predictive control","data-driven predictive control","energy-efficient buildings","demand response","robust model predictive control","thermal comfort management","building automation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.5075/epfl-thesis-11692","https://infoscience.epfl.ch/handle/20.500.14299/269383"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Model predictive control (MPC) can reduce building energy use and support demand-side flexibility. However, in practice, deployment is limited by model-commissioning effort, varying building dynamics, and prediction uncertainties. Standard MPC formulations also do not directly specify realized comfort-violation rate or severity. This thesis develops dependable data-driven control strategies for energy-efficient building systems. The first part develops two complementary methods for low-commissioning data-driven predictive control based on Willems' Fundamental Lemma. An efficient recursive data-enabled predictive control (DeePC) formulation keeps the computational cost fixed as operational data accumulate, while a physics-based filter enforces prescribed physical rules on predictions from noisy measurements. The second part tests the integration and sustained deployment of DeePC in real-world building control. An adaptive data-driven prediction layer is embedded in a bi-level DeePC hierarchy for secondary frequency control in a simulated Swiss ancillary-service market, where scenario-based day-ahead optimization and convex robust predictive control handle bidding and operational uncertainties. In a 52-day experiment at the Polydome, an occupied lecture hall on the EPFL campus, the controller coordinated a heat pump and a battery emulator. In selected periods with similar weather, it achieved about 24% lower average daily operating costs relative to two baseline scenarios. The third part addresses closed-loop comfort management through violation rate and severity. A disturbance-adaptive MPC framework establishes guarantees on average violation rate and is extended to data-driven building control. In eight Polydome field scenarios covering 76 days, the controller was tested with prescribed violation-rate bounds of 2.5%, 5%, and 10%. At the 5% bound, it reduced energy consumption by 20.5% relative to the default controller under similar weather conditions. A Kelvin-hour-budget MPC then shifts the prescribed quantity from violation rate to severity. It was evaluated through high-fidelity simulations and three six-day field deployments in an occupied home.","LA3"]},{"key":"dc:source","label":"Dc Source","values":["THESIS"]},{"key":"dc:title","label":"Title","values":["Dependable Data-driven Control Strategies for Energy-Efficient Building Systems"]}]}],"canonical_facts":{"dc:contributor":["Jones, Colin Neil"],"dc:creator":["Shi, Jicheng"],"dc:date":["2026-11-16T15:08:22Z","2026-11-16","2026","2026-11-17T12:30:48.792975Z"],"dc:description":["Model predictive control (MPC) can reduce building energy use and support demand-side flexibility. However, in practice, deployment is limited by model-commissioning effort, varying building dynamics, and prediction uncertainties. Standard MPC formulations also do not directly specify realized comfort-violation rate or severity. This thesis develops dependable data-driven control strategies for energy-efficient building systems. The first part develops two complementary methods for low-commissioning data-driven predictive control based on Willems' Fundamental Lemma. An efficient recursive data-enabled predictive control (DeePC) formulation keeps the computational cost fixed as operational data accumulate, while a physics-based filter enforces prescribed physical rules on predictions from noisy measurements. The second part tests the integration and sustained deployment of DeePC in real-world building control. An adaptive data-driven prediction layer is embedded in a bi-level DeePC hierarchy for secondary frequency control in a simulated Swiss ancillary-service market, where scenario-based day-ahead optimization and convex robust predictive control handle bidding and operational uncertainties. In a 52-day experiment at the Polydome, an occupied lecture hall on the EPFL campus, the controller coordinated a heat pump and a battery emulator. In selected periods with similar weather, it achieved about 24% lower average daily operating costs relative to two baseline scenarios. The third part addresses closed-loop comfort management through violation rate and severity. A disturbance-adaptive MPC framework establishes guarantees on average violation rate and is extended to data-driven building control. In eight Polydome field scenarios covering 76 days, the controller was tested with prescribed violation-rate bounds of 2.5%, 5%, and 10%. At the 5% bound, it reduced energy consumption by 20.5% relative to the default controller under similar weather conditions. A Kelvin-hour-budget MPC then shifts the prescribed quantity from violation rate to severity. It was evaluated through high-fidelity simulations and three six-day field deployments in an occupied home.","LA3"],"dc:identifier":["10.5075/epfl-thesis-11692","https://infoscience.epfl.ch/handle/20.500.14299/269383"],"dc:language":["eng"],"dc:publisher":["EPFL","Lausanne"],"dc:source":["THESIS"],"dc:subject":["model predictive control","data-driven predictive control","energy-efficient buildings","demand response","robust model predictive control","thermal comfort management","building automation"],"dc:title":["Dependable Data-driven Control Strategies for Energy-Efficient Building Systems"],"dc:type":["doctoral thesis"]},"updated_at":"2026-11-26T13:52:54Z"}