{"id":{"repo_id":"epfl","oai_identifier":"oai:infoscience.epfl.ch:20.500.14299/269395"},"canonical_url":"https://search.ndltd.org/etd/epfl/oai:infoscience.epfl.ch:20.500.14299/269395","repository":{"repo_id":"epfl","name":"EPFL","base_url":"https://infoscience.epfl.ch/server/oai/openaire4"},"display":{"title":"Multipanel Point-of-Care Electrochemical Biosensing Platform for Therapeutic Drug Monitoring in Precision Oncology","abstract":"Chemotherapy remains a cornerstone of cancer treatment, yet its clinical management is complicated by narrow therapeutic windows, pronounced inter-individual pharmacokinetic variability, and the routine co-administration of multiple drugs. These factors create a strong clinical need for therapeutic drug monitoring (TDM), which adjusts dosing to keep each patient within the therapeutic range. Current TDM relies on chromatographic and mass-spectrometric methods that are accurate but slow, costly, and confined to centralized laboratories, preventing the real-time, bedside feedback required for individualized dose optimization in oncology. This thesis develops an electrochemical biosensing platform for point-of-care TDM of six clinically relevant chemotherapeutic agents — cyclophosphamide, ifosfamide, etoposide, methotrexate, 5-fluorouracil, and busulfan — selected for their narrow therapeutic indices and high inter-individual variability. Because these drugs present a wide range of electrochemical behaviors, two complementary detection strategies were developed. Intrinsically electroactive drugs (etoposide, methotrexate, 5-fluorouracil) were detected directly at carbon electrodes; their simultaneous detection on a single sensor was demonstrated, and a previously uncharacterized mutual electrochemical cross-reactivity between etoposide and methotrexate was identified and mechanistically explained. Carboxylated multi-walled carbon nanotubes were further shown to selectively amplify the first oxidation peak of etoposide through an adsorption-mediated interfacial process. Non-electroactive drugs were addressed through enzyme-mediated transduction. Cytochrome P450 biosensors were built on nanostructured supports, comparing spinel oxide nanoparticles with platinum nanopetals; the latter enabled, to the best of our knowledge, the first demonstration of mediator-free direct electron transfer with CYP2B6, yielding a sensitivity exceeding previously reported CYP-based biosensors by more than one order of magnitude. For busulfan, which is neither electroactive nor a CYP substrate, the first inhibition-based electrochemical biosensor was realized through a glutathione S-transferase mechanism. These strategies were integrated into a dual-channel biosensor combining direct and enzymatic detection on a single substrate, enabling the detection of multiple drugs and their simultaneous measurement in clinically relevant combinations, without cross-interference between channels. The platform was validated in undiluted human serum, where matrix effects and electrode biofouling were mitigated using drug-specific strategies, including acetonitrile protein precipitation and a protective chitosan layer for the enzymatic electrodes. Finally, a dedicated, battery-powered electrochemical front-end supporting cyclic and differential pulse voltammetry, therapy-based operation, and wireless communication was designed and integrated onto a compact printed circuit board, reproducing benchtop-instrument performance in a portable form. Together, these contributions deliver a complete proof of concept for portable, multi-drug electrochemical TDM, a concrete step toward closed-loop, individualized chemotherapy management at the patient's bedside.","abstract_html":"Chemotherapy remains a cornerstone of cancer treatment, yet its clinical management is complicated by narrow therapeutic windows, pronounced inter-individual pharmacokinetic variability, and the routine co-administration of multiple drugs. These factors create a strong clinical need for therapeutic drug monitoring (TDM), which adjusts dosing to keep each patient within the therapeutic range. Current TDM relies on chromatographic and mass-spectrometric methods that are accurate but slow, costly, and confined to centralized laboratories, preventing the real-time, bedside feedback required for individualized dose optimization in oncology. This thesis develops an electrochemical biosensing platform for point-of-care TDM of six clinically relevant chemotherapeutic agents — cyclophosphamide, ifosfamide, etoposide, methotrexate, 5-fluorouracil, and busulfan — selected for their narrow therapeutic indices and high inter-individual variability. Because these drugs present a wide range of electrochemical behaviors, two complementary detection strategies were developed. Intrinsically electroactive drugs (etoposide, methotrexate, 5-fluorouracil) were detected directly at carbon electrodes; their simultaneous detection on a single sensor was demonstrated, and a previously uncharacterized mutual electrochemical cross-reactivity between etoposide and methotrexate was identified and mechanistically explained. Carboxylated multi-walled carbon nanotubes were further shown to selectively amplify the first oxidation peak of etoposide through an adsorption-mediated interfacial process. Non-electroactive drugs were addressed through enzyme-mediated transduction. Cytochrome P450 biosensors were built on nanostructured supports, comparing spinel oxide nanoparticles with platinum nanopetals; the latter enabled, to the best of our knowledge, the first demonstration of mediator-free direct electron transfer with CYP2B6, yielding a sensitivity exceeding previously reported CYP-based biosensors by more than one order of magnitude. For busulfan, which is neither electroactive nor a CYP substrate, the first inhibition-based electrochemical biosensor was realized through a glutathione S-transferase mechanism. These strategies were integrated into a dual-channel biosensor combining direct and enzymatic detection on a single substrate, enabling the detection of multiple drugs and their simultaneous measurement in clinically relevant combinations, without cross-interference between channels. The platform was validated in undiluted human serum, where matrix effects and electrode biofouling were mitigated using drug-specific strategies, including acetonitrile protein precipitation and a protective chitosan layer for the enzymatic electrodes. Finally, a dedicated, battery-powered electrochemical front-end supporting cyclic and differential pulse voltammetry, therapy-based operation, and wireless communication was designed and integrated onto a compact printed circuit board, reproducing benchtop-instrument performance in a portable form. Together, these contributions deliver a complete proof of concept for portable, multi-drug electrochemical TDM, a concrete step toward closed-loop, individualized chemotherapy management at the patient&#x27;s bedside.","abstract_has_math":false,"creators":["Rodino, Francesca"],"institution":"EPFL","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Carrara, Sandro"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-11-16T15:08:24Z","date_published":"2026-11-16T15:08:24Z","updated_at":"2026-11-26T13:50:41Z","subjects":["therapeutic drug monitoring","electrochemical biosensors","point-of-care diagnostics","precision oncology","chemotherapeutic drugs","nanostructured electrodes","cytochrome P450","multi-drug detection","portable potentiostat"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://infoscience.epfl.ch/handle/20.500.14299/269395"],"render_values":[{"text":"https://infoscience.epfl.ch/handle/20.500.14299/269395","href":"https://infoscience.epfl.ch/handle/20.500.14299/269395","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.5075/epfl-thesis-12239","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.5075/epfl-thesis-12239","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aepfl%3Aoai%3Ainfoscience.epfl.ch%3A20.500.14299%2F269395","prefix":"oai_dc"},"source_record":{"url":"https://infoscience.epfl.ch/server/oai/openaire4?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ainfoscience.epfl.ch%3A20.500.14299%2F269395","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Carrara, Sandro"]},{"key":"dc:creator","label":"Author","values":["Rodino, Francesca"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-11-16T15:08:24Z","2026-11-16","2026","2026-11-22T12:30:43.343715Z"]},{"key":"dc:publisher","label":"Institution","values":["EPFL","Lausanne"]},{"key":"dc:type","label":"Dc Type","values":["doctoral thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["therapeutic drug monitoring","electrochemical biosensors","point-of-care diagnostics","precision oncology","chemotherapeutic drugs","nanostructured electrodes","cytochrome P450","multi-drug detection","portable potentiostat"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.5075/epfl-thesis-12239","https://infoscience.epfl.ch/handle/20.500.14299/269395"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Chemotherapy remains a cornerstone of cancer treatment, yet its clinical management is complicated by narrow therapeutic windows, pronounced inter-individual pharmacokinetic variability, and the routine co-administration of multiple drugs. These factors create a strong clinical need for therapeutic drug monitoring (TDM), which adjusts dosing to keep each patient within the therapeutic range. Current TDM relies on chromatographic and mass-spectrometric methods that are accurate but slow, costly, and confined to centralized laboratories, preventing the real-time, bedside feedback required for individualized dose optimization in oncology. This thesis develops an electrochemical biosensing platform for point-of-care TDM of six clinically relevant chemotherapeutic agents — cyclophosphamide, ifosfamide, etoposide, methotrexate, 5-fluorouracil, and busulfan — selected for their narrow therapeutic indices and high inter-individual variability. Because these drugs present a wide range of electrochemical behaviors, two complementary detection strategies were developed. Intrinsically electroactive drugs (etoposide, methotrexate, 5-fluorouracil) were detected directly at carbon electrodes; their simultaneous detection on a single sensor was demonstrated, and a previously uncharacterized mutual electrochemical cross-reactivity between etoposide and methotrexate was identified and mechanistically explained. Carboxylated multi-walled carbon nanotubes were further shown to selectively amplify the first oxidation peak of etoposide through an adsorption-mediated interfacial process. Non-electroactive drugs were addressed through enzyme-mediated transduction. Cytochrome P450 biosensors were built on nanostructured supports, comparing spinel oxide nanoparticles with platinum nanopetals; the latter enabled, to the best of our knowledge, the first demonstration of mediator-free direct electron transfer with CYP2B6, yielding a sensitivity exceeding previously reported CYP-based biosensors by more than one order of magnitude. For busulfan, which is neither electroactive nor a CYP substrate, the first inhibition-based electrochemical biosensor was realized through a glutathione S-transferase mechanism. These strategies were integrated into a dual-channel biosensor combining direct and enzymatic detection on a single substrate, enabling the detection of multiple drugs and their simultaneous measurement in clinically relevant combinations, without cross-interference between channels. The platform was validated in undiluted human serum, where matrix effects and electrode biofouling were mitigated using drug-specific strategies, including acetonitrile protein precipitation and a protective chitosan layer for the enzymatic electrodes. Finally, a dedicated, battery-powered electrochemical front-end supporting cyclic and differential pulse voltammetry, therapy-based operation, and wireless communication was designed and integrated onto a compact printed circuit board, reproducing benchtop-instrument performance in a portable form. Together, these contributions deliver a complete proof of concept for portable, multi-drug electrochemical TDM, a concrete step toward closed-loop, individualized chemotherapy management at the patient's bedside.","ICLAB"]},{"key":"dc:source","label":"Dc Source","values":["THESIS"]},{"key":"dc:title","label":"Title","values":["Multipanel Point-of-Care Electrochemical Biosensing Platform for Therapeutic Drug Monitoring in Precision Oncology"]}]}],"canonical_facts":{"dc:contributor":["Carrara, Sandro"],"dc:creator":["Rodino, Francesca"],"dc:date":["2026-11-16T15:08:24Z","2026-11-16","2026","2026-11-22T12:30:43.343715Z"],"dc:description":["Chemotherapy remains a cornerstone of cancer treatment, yet its clinical management is complicated by narrow therapeutic windows, pronounced inter-individual pharmacokinetic variability, and the routine co-administration of multiple drugs. These factors create a strong clinical need for therapeutic drug monitoring (TDM), which adjusts dosing to keep each patient within the therapeutic range. Current TDM relies on chromatographic and mass-spectrometric methods that are accurate but slow, costly, and confined to centralized laboratories, preventing the real-time, bedside feedback required for individualized dose optimization in oncology. This thesis develops an electrochemical biosensing platform for point-of-care TDM of six clinically relevant chemotherapeutic agents — cyclophosphamide, ifosfamide, etoposide, methotrexate, 5-fluorouracil, and busulfan — selected for their narrow therapeutic indices and high inter-individual variability. Because these drugs present a wide range of electrochemical behaviors, two complementary detection strategies were developed. Intrinsically electroactive drugs (etoposide, methotrexate, 5-fluorouracil) were detected directly at carbon electrodes; their simultaneous detection on a single sensor was demonstrated, and a previously uncharacterized mutual electrochemical cross-reactivity between etoposide and methotrexate was identified and mechanistically explained. Carboxylated multi-walled carbon nanotubes were further shown to selectively amplify the first oxidation peak of etoposide through an adsorption-mediated interfacial process. Non-electroactive drugs were addressed through enzyme-mediated transduction. Cytochrome P450 biosensors were built on nanostructured supports, comparing spinel oxide nanoparticles with platinum nanopetals; the latter enabled, to the best of our knowledge, the first demonstration of mediator-free direct electron transfer with CYP2B6, yielding a sensitivity exceeding previously reported CYP-based biosensors by more than one order of magnitude. For busulfan, which is neither electroactive nor a CYP substrate, the first inhibition-based electrochemical biosensor was realized through a glutathione S-transferase mechanism. These strategies were integrated into a dual-channel biosensor combining direct and enzymatic detection on a single substrate, enabling the detection of multiple drugs and their simultaneous measurement in clinically relevant combinations, without cross-interference between channels. The platform was validated in undiluted human serum, where matrix effects and electrode biofouling were mitigated using drug-specific strategies, including acetonitrile protein precipitation and a protective chitosan layer for the enzymatic electrodes. Finally, a dedicated, battery-powered electrochemical front-end supporting cyclic and differential pulse voltammetry, therapy-based operation, and wireless communication was designed and integrated onto a compact printed circuit board, reproducing benchtop-instrument performance in a portable form. Together, these contributions deliver a complete proof of concept for portable, multi-drug electrochemical TDM, a concrete step toward closed-loop, individualized chemotherapy management at the patient's bedside.","ICLAB"],"dc:identifier":["10.5075/epfl-thesis-12239","https://infoscience.epfl.ch/handle/20.500.14299/269395"],"dc:language":["eng"],"dc:publisher":["EPFL","Lausanne"],"dc:source":["THESIS"],"dc:subject":["therapeutic drug monitoring","electrochemical biosensors","point-of-care diagnostics","precision oncology","chemotherapeutic drugs","nanostructured electrodes","cytochrome P450","multi-drug detection","portable potentiostat"],"dc:title":["Multipanel Point-of-Care Electrochemical Biosensing Platform for Therapeutic Drug Monitoring in Precision Oncology"],"dc:type":["doctoral thesis"]},"updated_at":"2026-11-26T13:50:41Z"}