{"id":{"repo_id":"epfl","oai_identifier":"oai:infoscience.tind.io:150554"},"canonical_url":"https://search.ndltd.org/etd/epfl/oai:infoscience.tind.io:150554","repository":{"repo_id":"epfl","name":"EPFL","base_url":"https://infoscience.epfl.ch/server/oai/openaire4"},"display":{"title":"Microelectronics Meets Biology : Manipulation and Detection of Microparticles and Cells Integrated On-Chip","abstract":"Microfluidics plays a key role in the design of automated platforms for realizing biological assays in a miniaturized format. Several advantages are offered by a microfluidic system, namely, low sample and reagent consumption (typically a few microliters), the possibility to mass-produce and to integrate several analysis modules enabling portable automated applications, fast analysis and low cost. Furthermore, the combination of advanced Complementary Metal-Oxide-Semiconductor (CMOS) technology and microfluidics can result in flexible and easy-to-use hybrid systems that hold large potential for application in an analytical laboratory or at the point-of-care. In this Thesis, two different monolithic silicon CMOS chips were designed, fabricated and tested, demonstrating state-of-the-art performance utilising a novel fluorescence detection principle. They allowed the detection of monoclonal antibodies in a solution or the precise counting of specifically labelled fluorescent cells in a mixed-cell sample. The proposed detection method does not require the utilization of a fluorescence camera and filter set. The first part of this Thesis presents different methods, fabrication processes and materials for microfluidic cartridges that can be integrated in a hybrid way with silicon CMOS chips. Glass and SU-8 capillaries are tested, a novel material (NOA 63) is proposed for fabricating a natively hydrophilic microfluidic cartridge, and the fabrication of custom-designed polydimethyl(-siloxane) (PDMS) cartridges for easy integration on top of a CMOS chip is introduced. The second part of this Thesis presents the combination of microfluidics with a monolithic and fully-integrated CMOS chip for the manipulation and detection of fluorescent magnetic beads, inside a PDMS microchannel that is loosely positioned on top of the chip. Magnetic manipulation is done by current actuation of microcoils on the chip; detection is achieved using single photon avalanche diodes (SPADs), located in the centre of each microcoil, that count the fluorescent photons originating from a single labeled magnetic bead. This approach permits in principle microscope-less fluorescence detection with high sensitivity. Using sandwich immunoassays on the beads' surfaces, the selective detection of the cancer biomarker 5D10 monoclonal antibody (mAb) from a non-purified hybridoma cell-culture medium is demonstrated. In the third part, a CMOS chip comprising a matrix of SPADs is designed, fabricated and tested. The recognition of single fluorescently-labelled cells from the breast cancer cell line MCF-7 in a test solution of mixed MCF-7 and non-fluorescent Jurkat cells is demonstrated, without the need of a bulky and expensive fluorescent microscope setup. Moreover, due to the use of a SPAD matrix spanning the complete width of the microchannel, the system does not require any cell focusing mechanism, needed when using a single detector. This allowed the use of a very simple, easily replicable and disposable plastic microfluidic cartridge.","abstract_html":"Microfluidics plays a key role in the design of automated platforms for realizing biological assays in a miniaturized format. Several advantages are offered by a microfluidic system, namely, low sample and reagent consumption (typically a few microliters), the possibility to mass-produce and to integrate several analysis modules enabling portable automated applications, fast analysis and low cost. Furthermore, the combination of advanced Complementary Metal-Oxide-Semiconductor (CMOS) technology and microfluidics can result in flexible and easy-to-use hybrid systems that hold large potential for application in an analytical laboratory or at the point-of-care. In this Thesis, two different monolithic silicon CMOS chips were designed, fabricated and tested, demonstrating state-of-the-art performance utilising a novel fluorescence detection principle. They allowed the detection of monoclonal antibodies in a solution or the precise counting of specifically labelled fluorescent cells in a mixed-cell sample. The proposed detection method does not require the utilization of a fluorescence camera and filter set. The first part of this Thesis presents different methods, fabrication processes and materials for microfluidic cartridges that can be integrated in a hybrid way with silicon CMOS chips. Glass and SU-8 capillaries are tested, a novel material (NOA 63) is proposed for fabricating a natively hydrophilic microfluidic cartridge, and the fabrication of custom-designed polydimethyl(-siloxane) (PDMS) cartridges for easy integration on top of a CMOS chip is introduced. The second part of this Thesis presents the combination of microfluidics with a monolithic and fully-integrated CMOS chip for the manipulation and detection of fluorescent magnetic beads, inside a PDMS microchannel that is loosely positioned on top of the chip. Magnetic manipulation is done by current actuation of microcoils on the chip; detection is achieved using single photon avalanche diodes (SPADs), located in the centre of each microcoil, that count the fluorescent photons originating from a single labeled magnetic bead. This approach permits in principle microscope-less fluorescence detection with high sensitivity. Using sandwich immunoassays on the beads&#x27; surfaces, the selective detection of the cancer biomarker 5D10 monoclonal antibody (mAb) from a non-purified hybridoma cell-culture medium is demonstrated. In the third part, a CMOS chip comprising a matrix of SPADs is designed, fabricated and tested. The recognition of single fluorescently-labelled cells from the breast cancer cell line MCF-7 in a test solution of mixed MCF-7 and non-fluorescent Jurkat cells is demonstrated, without the need of a bulky and expensive fluorescent microscope setup. Moreover, due to the use of a SPAD matrix spanning the complete width of the microchannel, the system does not require any cell focusing mechanism, needed when using a single detector. This allowed the use of a very simple, easily replicable and disposable plastic microfluidic cartridge.","abstract_has_math":false,"creators":["Dupont, Emile"],"institution":"EPFL","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Gijs, Martin"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-08-26T08:57:43","date_published":"2010-08-26T08:57:43","updated_at":"2026-11-26T13:50:23Z","subjects":["microfluidics","microelectronics","magnetic manipulation","optical detection","magnetic microparticle","single microparticle manipulation","single cell detection","single-photonavalanche-diodes","lab-on-a-chip","micro total-analysis-system","immunofluorescence","immunoassay","cell counting","MCF-7","5D10"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://infoscience.epfl.ch/handle/20.500.14299/52406","urn:nbn:ch:bel-epfl-thesis4849-3"],"render_values":[{"text":"https://infoscience.epfl.ch/handle/20.500.14299/52406","href":"https://infoscience.epfl.ch/handle/20.500.14299/52406","code":true},{"text":"urn:nbn:ch:bel-epfl-thesis4849-3","href":"https://nbn-resolving.org/urn:nbn:ch:bel-epfl-thesis4849-3","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.5075/epfl-thesis-4849","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.5075/epfl-thesis-4849","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aepfl%3Aoai%3Ainfoscience.tind.io%3A150554","prefix":"oai_dc"},"source_record":{"url":"https://infoscience.epfl.ch/server/oai/openaire4?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ainfoscience.tind.io%3A150554","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gijs, Martin"]},{"key":"dc:creator","label":"Author","values":["Dupont, Emile"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-08-26T08:57:43","2010-08-26","2010","2026-08-12T18:50:32.881722Z"]},{"key":"dc:publisher","label":"Institution","values":["EPFL","Lausanne"]},{"key":"dc:type","label":"Dc Type","values":["doctoral thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["microfluidics","microelectronics","magnetic manipulation","optical detection","magnetic microparticle","single microparticle manipulation","single cell detection","single-photonavalanche-diodes","lab-on-a-chip","micro total-analysis-system","immunofluorescence","immunoassay","cell counting","MCF-7","5D10"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.5075/epfl-thesis-4849","https://infoscience.epfl.ch/handle/20.500.14299/52406","urn:nbn:ch:bel-epfl-thesis4849-3"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Microfluidics plays a key role in the design of automated platforms for realizing biological assays in a miniaturized format. Several advantages are offered by a microfluidic system, namely, low sample and reagent consumption (typically a few microliters), the possibility to mass-produce and to integrate several analysis modules enabling portable automated applications, fast analysis and low cost. Furthermore, the combination of advanced Complementary Metal-Oxide-Semiconductor (CMOS) technology and microfluidics can result in flexible and easy-to-use hybrid systems that hold large potential for application in an analytical laboratory or at the point-of-care. In this Thesis, two different monolithic silicon CMOS chips were designed, fabricated and tested, demonstrating state-of-the-art performance utilising a novel fluorescence detection principle. They allowed the detection of monoclonal antibodies in a solution or the precise counting of specifically labelled fluorescent cells in a mixed-cell sample. The proposed detection method does not require the utilization of a fluorescence camera and filter set. The first part of this Thesis presents different methods, fabrication processes and materials for microfluidic cartridges that can be integrated in a hybrid way with silicon CMOS chips. Glass and SU-8 capillaries are tested, a novel material (NOA 63) is proposed for fabricating a natively hydrophilic microfluidic cartridge, and the fabrication of custom-designed polydimethyl(-siloxane) (PDMS) cartridges for easy integration on top of a CMOS chip is introduced. The second part of this Thesis presents the combination of microfluidics with a monolithic and fully-integrated CMOS chip for the manipulation and detection of fluorescent magnetic beads, inside a PDMS microchannel that is loosely positioned on top of the chip. Magnetic manipulation is done by current actuation of microcoils on the chip; detection is achieved using single photon avalanche diodes (SPADs), located in the centre of each microcoil, that count the fluorescent photons originating from a single labeled magnetic bead. This approach permits in principle microscope-less fluorescence detection with high sensitivity. Using sandwich immunoassays on the beads' surfaces, the selective detection of the cancer biomarker 5D10 monoclonal antibody (mAb) from a non-purified hybridoma cell-culture medium is demonstrated. In the third part, a CMOS chip comprising a matrix of SPADs is designed, fabricated and tested. The recognition of single fluorescently-labelled cells from the breast cancer cell line MCF-7 in a test solution of mixed MCF-7 and non-fluorescent Jurkat cells is demonstrated, without the need of a bulky and expensive fluorescent microscope setup. Moreover, due to the use of a SPAD matrix spanning the complete width of the microchannel, the system does not require any cell focusing mechanism, needed when using a single detector. This allowed the use of a very simple, easily replicable and disposable plastic microfluidic cartridge.","LMIS2"]},{"key":"dc:title","label":"Title","values":["Microelectronics Meets Biology : Manipulation and Detection of Microparticles and Cells Integrated On-Chip"]}]}],"canonical_facts":{"dc:contributor":["Gijs, Martin"],"dc:creator":["Dupont, Emile"],"dc:date":["2010-08-26T08:57:43","2010-08-26","2010","2026-08-12T18:50:32.881722Z"],"dc:description":["Microfluidics plays a key role in the design of automated platforms for realizing biological assays in a miniaturized format. Several advantages are offered by a microfluidic system, namely, low sample and reagent consumption (typically a few microliters), the possibility to mass-produce and to integrate several analysis modules enabling portable automated applications, fast analysis and low cost. Furthermore, the combination of advanced Complementary Metal-Oxide-Semiconductor (CMOS) technology and microfluidics can result in flexible and easy-to-use hybrid systems that hold large potential for application in an analytical laboratory or at the point-of-care. In this Thesis, two different monolithic silicon CMOS chips were designed, fabricated and tested, demonstrating state-of-the-art performance utilising a novel fluorescence detection principle. They allowed the detection of monoclonal antibodies in a solution or the precise counting of specifically labelled fluorescent cells in a mixed-cell sample. The proposed detection method does not require the utilization of a fluorescence camera and filter set. The first part of this Thesis presents different methods, fabrication processes and materials for microfluidic cartridges that can be integrated in a hybrid way with silicon CMOS chips. Glass and SU-8 capillaries are tested, a novel material (NOA 63) is proposed for fabricating a natively hydrophilic microfluidic cartridge, and the fabrication of custom-designed polydimethyl(-siloxane) (PDMS) cartridges for easy integration on top of a CMOS chip is introduced. The second part of this Thesis presents the combination of microfluidics with a monolithic and fully-integrated CMOS chip for the manipulation and detection of fluorescent magnetic beads, inside a PDMS microchannel that is loosely positioned on top of the chip. Magnetic manipulation is done by current actuation of microcoils on the chip; detection is achieved using single photon avalanche diodes (SPADs), located in the centre of each microcoil, that count the fluorescent photons originating from a single labeled magnetic bead. This approach permits in principle microscope-less fluorescence detection with high sensitivity. Using sandwich immunoassays on the beads' surfaces, the selective detection of the cancer biomarker 5D10 monoclonal antibody (mAb) from a non-purified hybridoma cell-culture medium is demonstrated. In the third part, a CMOS chip comprising a matrix of SPADs is designed, fabricated and tested. The recognition of single fluorescently-labelled cells from the breast cancer cell line MCF-7 in a test solution of mixed MCF-7 and non-fluorescent Jurkat cells is demonstrated, without the need of a bulky and expensive fluorescent microscope setup. Moreover, due to the use of a SPAD matrix spanning the complete width of the microchannel, the system does not require any cell focusing mechanism, needed when using a single detector. This allowed the use of a very simple, easily replicable and disposable plastic microfluidic cartridge.","LMIS2"],"dc:identifier":["10.5075/epfl-thesis-4849","https://infoscience.epfl.ch/handle/20.500.14299/52406","urn:nbn:ch:bel-epfl-thesis4849-3"],"dc:language":["eng"],"dc:publisher":["EPFL","Lausanne"],"dc:subject":["microfluidics","microelectronics","magnetic manipulation","optical detection","magnetic microparticle","single microparticle manipulation","single cell detection","single-photonavalanche-diodes","lab-on-a-chip","micro total-analysis-system","immunofluorescence","immunoassay","cell counting","MCF-7","5D10"],"dc:title":["Microelectronics Meets Biology : Manipulation and Detection of Microparticles and Cells Integrated On-Chip"],"dc:type":["doctoral thesis"]},"updated_at":"2026-11-26T13:50:23Z"}