{"id":{"repo_id":"epfl","oai_identifier":"oai:infoscience.tind.io:181531"},"canonical_url":"https://search.ndltd.org/etd/epfl/oai:infoscience.tind.io:181531","repository":{"repo_id":"epfl","name":"EPFL","base_url":"https://infoscience.epfl.ch/server/oai/openaire4"},"display":{"title":"Automated Analysis of Rare Biomarkers Using a Magnetic Bead Surface Coverage Assay Coupled with Chaotic Mixing on a Microfluidic Chip","abstract":"Extremely sensitive protein detection is crucial for early diagnosis and monitoring of diseases. Present day’s limit of detection for an antibody-antigen recognition-based immunoassay in serum without having to use special target antigen amplification techniques, like immuno-linked polymerase chain reaction (PCR), is 10 fg/mL, a sensitivity achieved thanks to the use of relatively large sample volumes (40-100 μL). In this thesis, a new method is developed to analyze rare protein biomarkers in a serum sample using a magnetic bead surface coverage assay. The assay protocols are realized on a microfluidic chip having channels, valves, an integrated mixer, and a protein micro-array. The microfluidic chip provides automated analysis, minute sample consumption (5 μL), resulting in an unprecedented 2 fg/mL detection performance for Tumor Necrosis Factor-α (TNF-α) in serum. A first part of the thesis consists in fabricating protein micro-arrays using the surface of immobilized ‘small’ (1.0 μm size) superparamagnetic beads that are placed in microfluidic flow channels. The small beads are immobilized on a glass chip with pre-patterned aminopropyl- trietoxysilane (APTES) structures using an electrostatic self-assembly method. Different target antigens are captured from a flow passing over the micro-array inside the microfluidic channel, and are specifically bound on the small bead surfaces. The presence of target antigens is detected as a fluorescent signal by realizing a sandwich immunocomplex on the capture antibody-functionalized surfaces of the small beads. However, the fluorescent detection method is abandoned due to high fluorescence background levels, resulting in only a 0.25 ng/mL detection limit for mouse immunoglobulin in phosphate-buffered saline. In a second part of the thesis, a polydimethylsiloxane (PDMS) chip having microfluidic channels, valves and an integrated mixer is designed. A new active mixing strategy is performed in the chip using multiple source-sink microfluidic flows. To do so, four different pressure- controlled actuation chambers are arranged on top of the 5 μL volume of the mixing chamber. After microfluidic valves, realized using ‘microplumbing technology’, seal the mixing volume, a virtual source-sink pair is created by pressurizing one of the membranes and, at the same time, releasing the pressure of a neighboring one. This creates microfluidic flows from the squeezed region (source) to the released region (sink) where the PDMS membrane is turned into the initial state. Perfect mixing is 7000-fold faster than achievable with pure diffusion-based mixing. This excellent performance is possible thanks to the implementation of chaotic advection by inducing vortices inside the mixing chamber. A DNA isolation and purification protocol using magnetic beads in the mixing chamber is also performed on-chip, showing the enhanced DNA binding performance due to active mixing. Finally, a new protein detection method is realized in a microfluidic chip. ‘Large’ (2.8 μm size) functionalized superparamagnetic beads specifically capture target antigens from a serum matrix under active microfluidic mixing. Subsequently, the large beads loaded with the antigens gently expose antibody-functionalized small bead patterns on the glass detection chip. During the exposure, attractive magnetic bead dipole-dipole interactions improve the contact between the two bead types and help the antigen-antibody immunocomplex formation, while non- specific large bead adsorption is limited by exploiting viscous drag forces in the microfluidic channel on the detection chip. This efficient transport mimics a biological process, where leukocytes roll and slow down on blood vessel walls by selectin-mediated adhesion for rapid recognition of tissue molecules. Afterwards, the antigen concentration is detected by simply counting the surface pattern-bound large magnetic beads. The new technique allows detection of only a few hundreds of TNF-α molecules (600 yoctomole) spiked in the 5 μL serum sample. This performance, in terms of detectable number of molecules, is at least 20 times better than today’s most-sensitive PCR-free antibody-based methods. Furthermore, the method has the supplementary advantage of being rapid, resulting from the automated assay protocols and the extremely fast (1 minute) antigen capture.","abstract_html":"Extremely sensitive protein detection is crucial for early diagnosis and monitoring of diseases. Present day’s limit of detection for an antibody-antigen recognition-based immunoassay in serum without having to use special target antigen amplification techniques, like immuno-linked polymerase chain reaction (PCR), is 10 fg/mL, a sensitivity achieved thanks to the use of relatively large sample volumes (40-100 μL). In this thesis, a new method is developed to analyze rare protein biomarkers in a serum sample using a magnetic bead surface coverage assay. The assay protocols are realized on a microfluidic chip having channels, valves, an integrated mixer, and a protein micro-array. The microfluidic chip provides automated analysis, minute sample consumption (5 μL), resulting in an unprecedented 2 fg/mL detection performance for Tumor Necrosis Factor-α (TNF-α) in serum. A first part of the thesis consists in fabricating protein micro-arrays using the surface of immobilized ‘small’ (1.0 μm size) superparamagnetic beads that are placed in microfluidic flow channels. The small beads are immobilized on a glass chip with pre-patterned aminopropyl- trietoxysilane (APTES) structures using an electrostatic self-assembly method. Different target antigens are captured from a flow passing over the micro-array inside the microfluidic channel, and are specifically bound on the small bead surfaces. The presence of target antigens is detected as a fluorescent signal by realizing a sandwich immunocomplex on the capture antibody-functionalized surfaces of the small beads. However, the fluorescent detection method is abandoned due to high fluorescence background levels, resulting in only a 0.25 ng/mL detection limit for mouse immunoglobulin in phosphate-buffered saline. In a second part of the thesis, a polydimethylsiloxane (PDMS) chip having microfluidic channels, valves and an integrated mixer is designed. A new active mixing strategy is performed in the chip using multiple source-sink microfluidic flows. To do so, four different pressure- controlled actuation chambers are arranged on top of the 5 μL volume of the mixing chamber. After microfluidic valves, realized using ‘microplumbing technology’, seal the mixing volume, a virtual source-sink pair is created by pressurizing one of the membranes and, at the same time, releasing the pressure of a neighboring one. This creates microfluidic flows from the squeezed region (source) to the released region (sink) where the PDMS membrane is turned into the initial state. Perfect mixing is 7000-fold faster than achievable with pure diffusion-based mixing. This excellent performance is possible thanks to the implementation of chaotic advection by inducing vortices inside the mixing chamber. A DNA isolation and purification protocol using magnetic beads in the mixing chamber is also performed on-chip, showing the enhanced DNA binding performance due to active mixing. Finally, a new protein detection method is realized in a microfluidic chip. ‘Large’ (2.8 μm size) functionalized superparamagnetic beads specifically capture target antigens from a serum matrix under active microfluidic mixing. Subsequently, the large beads loaded with the antigens gently expose antibody-functionalized small bead patterns on the glass detection chip. During the exposure, attractive magnetic bead dipole-dipole interactions improve the contact between the two bead types and help the antigen-antibody immunocomplex formation, while non- specific large bead adsorption is limited by exploiting viscous drag forces in the microfluidic channel on the detection chip. This efficient transport mimics a biological process, where leukocytes roll and slow down on blood vessel walls by selectin-mediated adhesion for rapid recognition of tissue molecules. Afterwards, the antigen concentration is detected by simply counting the surface pattern-bound large magnetic beads. The new technique allows detection of only a few hundreds of TNF-α molecules (600 yoctomole) spiked in the 5 μL serum sample. This performance, in terms of detectable number of molecules, is at least 20 times better than today’s most-sensitive PCR-free antibody-based methods. Furthermore, the method has the supplementary advantage of being rapid, resulting from the automated assay protocols and the extremely fast (1 minute) antigen capture.","abstract_has_math":false,"creators":["Tekin, Hüseyin Cumhur"],"institution":"EPFL","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Gijs, Martin"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-09-27T16:13:04","date_published":"2012-09-27T16:13:04","updated_at":"2026-11-26T13:53:34Z","subjects":["Microfluidics","Lab-on-a-chip","Sandwich immunoassays","Micro-arrays","Immunofluorescence assays","Surface coverage assays","Magnetic dipolar interaction","Chaotic advection","Source-sink flows","Electrostatic self assembly","Mixer","Valve","PDMS","SU-8","APTES","Superparamagnetic beads","DNA purification","Immunoglobulin","Streptavidin","Anti-streptavidin","TNF-a","Serum"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://infoscience.epfl.ch/handle/20.500.14299/85760","urn:nbn:ch:bel-epfl-thesis5496-8"],"render_values":[{"text":"https://infoscience.epfl.ch/handle/20.500.14299/85760","href":"https://infoscience.epfl.ch/handle/20.500.14299/85760","code":true},{"text":"urn:nbn:ch:bel-epfl-thesis5496-8","href":"https://nbn-resolving.org/urn:nbn:ch:bel-epfl-thesis5496-8","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.5075/epfl-thesis-5496","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.5075/epfl-thesis-5496","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aepfl%3Aoai%3Ainfoscience.tind.io%3A181531","prefix":"oai_dc"},"source_record":{"url":"https://infoscience.epfl.ch/server/oai/openaire4?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ainfoscience.tind.io%3A181531","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gijs, Martin"]},{"key":"dc:creator","label":"Author","values":["Tekin, Hüseyin Cumhur"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-09-27T16:13:04","2012-09-27","2012","2026-08-15T00:40:31.410308Z"]},{"key":"dc:publisher","label":"Institution","values":["EPFL","Lausanne"]},{"key":"dc:type","label":"Dc Type","values":["doctoral thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microfluidics","Lab-on-a-chip","Sandwich immunoassays","Micro-arrays","Immunofluorescence assays","Surface coverage assays","Magnetic dipolar interaction","Chaotic advection","Source-sink flows","Electrostatic self assembly","Mixer","Valve","PDMS","SU-8","APTES","Superparamagnetic beads","DNA purification","Immunoglobulin","Streptavidin","Anti-streptavidin","TNF-a","Serum"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.5075/epfl-thesis-5496","https://infoscience.epfl.ch/handle/20.500.14299/85760","urn:nbn:ch:bel-epfl-thesis5496-8"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Extremely sensitive protein detection is crucial for early diagnosis and monitoring of diseases. Present day’s limit of detection for an antibody-antigen recognition-based immunoassay in serum without having to use special target antigen amplification techniques, like immuno-linked polymerase chain reaction (PCR), is 10 fg/mL, a sensitivity achieved thanks to the use of relatively large sample volumes (40-100 μL). In this thesis, a new method is developed to analyze rare protein biomarkers in a serum sample using a magnetic bead surface coverage assay. The assay protocols are realized on a microfluidic chip having channels, valves, an integrated mixer, and a protein micro-array. The microfluidic chip provides automated analysis, minute sample consumption (5 μL), resulting in an unprecedented 2 fg/mL detection performance for Tumor Necrosis Factor-α (TNF-α) in serum. A first part of the thesis consists in fabricating protein micro-arrays using the surface of immobilized ‘small’ (1.0 μm size) superparamagnetic beads that are placed in microfluidic flow channels. The small beads are immobilized on a glass chip with pre-patterned aminopropyl- trietoxysilane (APTES) structures using an electrostatic self-assembly method. Different target antigens are captured from a flow passing over the micro-array inside the microfluidic channel, and are specifically bound on the small bead surfaces. The presence of target antigens is detected as a fluorescent signal by realizing a sandwich immunocomplex on the capture antibody-functionalized surfaces of the small beads. However, the fluorescent detection method is abandoned due to high fluorescence background levels, resulting in only a 0.25 ng/mL detection limit for mouse immunoglobulin in phosphate-buffered saline. In a second part of the thesis, a polydimethylsiloxane (PDMS) chip having microfluidic channels, valves and an integrated mixer is designed. A new active mixing strategy is performed in the chip using multiple source-sink microfluidic flows. To do so, four different pressure- controlled actuation chambers are arranged on top of the 5 μL volume of the mixing chamber. After microfluidic valves, realized using ‘microplumbing technology’, seal the mixing volume, a virtual source-sink pair is created by pressurizing one of the membranes and, at the same time, releasing the pressure of a neighboring one. This creates microfluidic flows from the squeezed region (source) to the released region (sink) where the PDMS membrane is turned into the initial state. Perfect mixing is 7000-fold faster than achievable with pure diffusion-based mixing. This excellent performance is possible thanks to the implementation of chaotic advection by inducing vortices inside the mixing chamber. A DNA isolation and purification protocol using magnetic beads in the mixing chamber is also performed on-chip, showing the enhanced DNA binding performance due to active mixing. Finally, a new protein detection method is realized in a microfluidic chip. ‘Large’ (2.8 μm size) functionalized superparamagnetic beads specifically capture target antigens from a serum matrix under active microfluidic mixing. Subsequently, the large beads loaded with the antigens gently expose antibody-functionalized small bead patterns on the glass detection chip. During the exposure, attractive magnetic bead dipole-dipole interactions improve the contact between the two bead types and help the antigen-antibody immunocomplex formation, while non- specific large bead adsorption is limited by exploiting viscous drag forces in the microfluidic channel on the detection chip. This efficient transport mimics a biological process, where leukocytes roll and slow down on blood vessel walls by selectin-mediated adhesion for rapid recognition of tissue molecules. Afterwards, the antigen concentration is detected by simply counting the surface pattern-bound large magnetic beads. The new technique allows detection of only a few hundreds of TNF-α molecules (600 yoctomole) spiked in the 5 μL serum sample. This performance, in terms of detectable number of molecules, is at least 20 times better than today’s most-sensitive PCR-free antibody-based methods. Furthermore, the method has the supplementary advantage of being rapid, resulting from the automated assay protocols and the extremely fast (1 minute) antigen capture.","LMIS2"]},{"key":"dc:title","label":"Title","values":["Automated Analysis of Rare Biomarkers Using a Magnetic Bead Surface Coverage Assay Coupled with Chaotic Mixing on a Microfluidic Chip"]}]}],"canonical_facts":{"dc:contributor":["Gijs, Martin"],"dc:creator":["Tekin, Hüseyin Cumhur"],"dc:date":["2012-09-27T16:13:04","2012-09-27","2012","2026-08-15T00:40:31.410308Z"],"dc:description":["Extremely sensitive protein detection is crucial for early diagnosis and monitoring of diseases. Present day’s limit of detection for an antibody-antigen recognition-based immunoassay in serum without having to use special target antigen amplification techniques, like immuno-linked polymerase chain reaction (PCR), is 10 fg/mL, a sensitivity achieved thanks to the use of relatively large sample volumes (40-100 μL). In this thesis, a new method is developed to analyze rare protein biomarkers in a serum sample using a magnetic bead surface coverage assay. The assay protocols are realized on a microfluidic chip having channels, valves, an integrated mixer, and a protein micro-array. The microfluidic chip provides automated analysis, minute sample consumption (5 μL), resulting in an unprecedented 2 fg/mL detection performance for Tumor Necrosis Factor-α (TNF-α) in serum. A first part of the thesis consists in fabricating protein micro-arrays using the surface of immobilized ‘small’ (1.0 μm size) superparamagnetic beads that are placed in microfluidic flow channels. The small beads are immobilized on a glass chip with pre-patterned aminopropyl- trietoxysilane (APTES) structures using an electrostatic self-assembly method. Different target antigens are captured from a flow passing over the micro-array inside the microfluidic channel, and are specifically bound on the small bead surfaces. The presence of target antigens is detected as a fluorescent signal by realizing a sandwich immunocomplex on the capture antibody-functionalized surfaces of the small beads. However, the fluorescent detection method is abandoned due to high fluorescence background levels, resulting in only a 0.25 ng/mL detection limit for mouse immunoglobulin in phosphate-buffered saline. In a second part of the thesis, a polydimethylsiloxane (PDMS) chip having microfluidic channels, valves and an integrated mixer is designed. A new active mixing strategy is performed in the chip using multiple source-sink microfluidic flows. To do so, four different pressure- controlled actuation chambers are arranged on top of the 5 μL volume of the mixing chamber. After microfluidic valves, realized using ‘microplumbing technology’, seal the mixing volume, a virtual source-sink pair is created by pressurizing one of the membranes and, at the same time, releasing the pressure of a neighboring one. This creates microfluidic flows from the squeezed region (source) to the released region (sink) where the PDMS membrane is turned into the initial state. Perfect mixing is 7000-fold faster than achievable with pure diffusion-based mixing. This excellent performance is possible thanks to the implementation of chaotic advection by inducing vortices inside the mixing chamber. A DNA isolation and purification protocol using magnetic beads in the mixing chamber is also performed on-chip, showing the enhanced DNA binding performance due to active mixing. Finally, a new protein detection method is realized in a microfluidic chip. ‘Large’ (2.8 μm size) functionalized superparamagnetic beads specifically capture target antigens from a serum matrix under active microfluidic mixing. Subsequently, the large beads loaded with the antigens gently expose antibody-functionalized small bead patterns on the glass detection chip. During the exposure, attractive magnetic bead dipole-dipole interactions improve the contact between the two bead types and help the antigen-antibody immunocomplex formation, while non- specific large bead adsorption is limited by exploiting viscous drag forces in the microfluidic channel on the detection chip. This efficient transport mimics a biological process, where leukocytes roll and slow down on blood vessel walls by selectin-mediated adhesion for rapid recognition of tissue molecules. Afterwards, the antigen concentration is detected by simply counting the surface pattern-bound large magnetic beads. The new technique allows detection of only a few hundreds of TNF-α molecules (600 yoctomole) spiked in the 5 μL serum sample. This performance, in terms of detectable number of molecules, is at least 20 times better than today’s most-sensitive PCR-free antibody-based methods. Furthermore, the method has the supplementary advantage of being rapid, resulting from the automated assay protocols and the extremely fast (1 minute) antigen capture.","LMIS2"],"dc:identifier":["10.5075/epfl-thesis-5496","https://infoscience.epfl.ch/handle/20.500.14299/85760","urn:nbn:ch:bel-epfl-thesis5496-8"],"dc:language":["eng"],"dc:publisher":["EPFL","Lausanne"],"dc:subject":["Microfluidics","Lab-on-a-chip","Sandwich immunoassays","Micro-arrays","Immunofluorescence assays","Surface coverage assays","Magnetic dipolar interaction","Chaotic advection","Source-sink flows","Electrostatic self assembly","Mixer","Valve","PDMS","SU-8","APTES","Superparamagnetic beads","DNA purification","Immunoglobulin","Streptavidin","Anti-streptavidin","TNF-a","Serum"],"dc:title":["Automated Analysis of Rare Biomarkers Using a Magnetic Bead Surface Coverage Assay Coupled with Chaotic Mixing on a Microfluidic Chip"],"dc:type":["doctoral thesis"]},"updated_at":"2026-11-26T13:53:34Z"}