{"id":{"repo_id":"epfl","oai_identifier":"oai:infoscience.tind.io:182689"},"canonical_url":"https://search.ndltd.org/etd/epfl/oai:infoscience.tind.io:182689","repository":{"repo_id":"epfl","name":"EPFL","base_url":"https://infoscience.epfl.ch/server/oai/openaire4"},"display":{"title":"Integrated Microfluidic Liquid-Liquid Extraction for Cocaine Detection in Human Saliva","abstract":"On-site drug testing using easily accessible body fluids, such as saliva, has gained a lot of importance both for road safety and forensic applications. However, saliva is a complex, inhomogeneous amalgam with many different compounds, whose concentrations change between people and over time. This leads to a wide range of fluid properties, e.g., viscosity, surface tension, making saliva pretreatment in microfluidic systems extremely challenging. We present the development, fabrication and characterization of a low-cost, portable microsystem to detect cocaine in human saliva. The chip combines multiphase liquid-liquid extraction to transfer the cocaine from the infrared (IR) light absorbing saliva to the IR-transparent solvent, perchloroethylene (PCE), together with on-chip cocaine detection by IR-spectroscopy (IR-laser, waveguide, detector). This miniaturized sensing platform has been developed as part of the Nano-Tera project IrSens. Saliva is a suitable matrix for the analysis of small molecules such as cocaine, but it is found to be a challenge to process this complex fluid on a microfluidic chip due to the risk of clogging. The characterization of the rheological behavior of saliva is described and then a suitable sample pretreatment method is presented. The low-cost UV-curable polymer NOA81 was chosen as microfluidic chip material and characterized for microfluidic applications. For research applications a new, highly flexible, and low-cost NOA81 rapid prototyping method is presented based on scotch-tape masters. Furthermore, this thesis introduces a microfluidic chip design combining a simple and robust droplet generation method together with a geometry for droplet merging in order to perform continuous droplet-based liquid-liquid extraction. The extraction efficiency of the system was evaluated by state-of-the-art mass spectrometry measurements. The microfluidic chip has been integrated in an optofluidic microsystem transferring cocaine from human saliva to the IR-transparent organic solvent PCE and thereby enabling cocaine detection by IR-spectroscopy. In this thesis we achieved to develop a simple and robust droplet generation method re- sulting in precise and controlled droplet sizes, and which allowed to process complex fluids such as human saliva without clogging. Furthermore, a droplet-based liquid-liquid extraction system which transfers the cocaine continuously from human saliva to the organic solvent PCE was established. For these liquids the developed system yielded a two to three times higher extraction efficiency than state-of-the-art devices. In addition, we demonstrated that our system has the potential for cocaine preconcentration in PCE, which is crucial for IR spectroscopy, our final application.","abstract_html":"On-site drug testing using easily accessible body fluids, such as saliva, has gained a lot of importance both for road safety and forensic applications. However, saliva is a complex, inhomogeneous amalgam with many different compounds, whose concentrations change between people and over time. This leads to a wide range of fluid properties, e.g., viscosity, surface tension, making saliva pretreatment in microfluidic systems extremely challenging. We present the development, fabrication and characterization of a low-cost, portable microsystem to detect cocaine in human saliva. The chip combines multiphase liquid-liquid extraction to transfer the cocaine from the infrared (IR) light absorbing saliva to the IR-transparent solvent, perchloroethylene (PCE), together with on-chip cocaine detection by IR-spectroscopy (IR-laser, waveguide, detector). This miniaturized sensing platform has been developed as part of the Nano-Tera project IrSens. Saliva is a suitable matrix for the analysis of small molecules such as cocaine, but it is found to be a challenge to process this complex fluid on a microfluidic chip due to the risk of clogging. The characterization of the rheological behavior of saliva is described and then a suitable sample pretreatment method is presented. The low-cost UV-curable polymer NOA81 was chosen as microfluidic chip material and characterized for microfluidic applications. For research applications a new, highly flexible, and low-cost NOA81 rapid prototyping method is presented based on scotch-tape masters. Furthermore, this thesis introduces a microfluidic chip design combining a simple and robust droplet generation method together with a geometry for droplet merging in order to perform continuous droplet-based liquid-liquid extraction. The extraction efficiency of the system was evaluated by state-of-the-art mass spectrometry measurements. The microfluidic chip has been integrated in an optofluidic microsystem transferring cocaine from human saliva to the IR-transparent organic solvent PCE and thereby enabling cocaine detection by IR-spectroscopy. In this thesis we achieved to develop a simple and robust droplet generation method re- sulting in precise and controlled droplet sizes, and which allowed to process complex fluids such as human saliva without clogging. Furthermore, a droplet-based liquid-liquid extraction system which transfers the cocaine continuously from human saliva to the organic solvent PCE was established. For these liquids the developed system yielded a two to three times higher extraction efficiency than state-of-the-art devices. In addition, we demonstrated that our system has the potential for cocaine preconcentration in PCE, which is crucial for IR spectroscopy, our final application.","abstract_has_math":false,"creators":["Wägli, Philip"],"institution":"EPFL","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Rooij, Nicolaas Frans de","Homsy, Alexandra"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-12-05T15:08:45","date_published":"2012-12-05T15:08:45","updated_at":"2026-11-26T13:50:21Z","subjects":["microfluidic","saliva","cocaine","UV-curable adhesive NOA81","rapid prototyping","continuous liquid-liquid extraction","droplet generation","droplet coalescence","IR-spectroscopy"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://infoscience.epfl.ch/handle/20.500.14299/87285","urn:nbn:ch:bel-epfl-thesis5589-6"],"render_values":[{"text":"https://infoscience.epfl.ch/handle/20.500.14299/87285","href":"https://infoscience.epfl.ch/handle/20.500.14299/87285","code":true},{"text":"urn:nbn:ch:bel-epfl-thesis5589-6","href":"https://nbn-resolving.org/urn:nbn:ch:bel-epfl-thesis5589-6","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.5075/epfl-thesis-5589","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.5075/epfl-thesis-5589","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aepfl%3Aoai%3Ainfoscience.tind.io%3A182689","prefix":"oai_dc"},"source_record":{"url":"https://infoscience.epfl.ch/server/oai/openaire4?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ainfoscience.tind.io%3A182689","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Rooij, Nicolaas Frans de","Homsy, Alexandra"]},{"key":"dc:creator","label":"Author","values":["Wägli, Philip"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-12-05T15:08:45","2012-12-05","2012","2026-08-12T18:29:50.603246Z"]},{"key":"dc:publisher","label":"Institution","values":["EPFL","Lausanne"]},{"key":"dc:type","label":"Dc Type","values":["doctoral thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["microfluidic","saliva","cocaine","UV-curable adhesive NOA81","rapid prototyping","continuous liquid-liquid extraction","droplet generation","droplet coalescence","IR-spectroscopy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.5075/epfl-thesis-5589","https://infoscience.epfl.ch/handle/20.500.14299/87285","urn:nbn:ch:bel-epfl-thesis5589-6"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["On-site drug testing using easily accessible body fluids, such as saliva, has gained a lot of importance both for road safety and forensic applications. However, saliva is a complex, inhomogeneous amalgam with many different compounds, whose concentrations change between people and over time. This leads to a wide range of fluid properties, e.g., viscosity, surface tension, making saliva pretreatment in microfluidic systems extremely challenging. We present the development, fabrication and characterization of a low-cost, portable microsystem to detect cocaine in human saliva. The chip combines multiphase liquid-liquid extraction to transfer the cocaine from the infrared (IR) light absorbing saliva to the IR-transparent solvent, perchloroethylene (PCE), together with on-chip cocaine detection by IR-spectroscopy (IR-laser, waveguide, detector). This miniaturized sensing platform has been developed as part of the Nano-Tera project IrSens. Saliva is a suitable matrix for the analysis of small molecules such as cocaine, but it is found to be a challenge to process this complex fluid on a microfluidic chip due to the risk of clogging. The characterization of the rheological behavior of saliva is described and then a suitable sample pretreatment method is presented. The low-cost UV-curable polymer NOA81 was chosen as microfluidic chip material and characterized for microfluidic applications. For research applications a new, highly flexible, and low-cost NOA81 rapid prototyping method is presented based on scotch-tape masters. Furthermore, this thesis introduces a microfluidic chip design combining a simple and robust droplet generation method together with a geometry for droplet merging in order to perform continuous droplet-based liquid-liquid extraction. The extraction efficiency of the system was evaluated by state-of-the-art mass spectrometry measurements. The microfluidic chip has been integrated in an optofluidic microsystem transferring cocaine from human saliva to the IR-transparent organic solvent PCE and thereby enabling cocaine detection by IR-spectroscopy. In this thesis we achieved to develop a simple and robust droplet generation method re- sulting in precise and controlled droplet sizes, and which allowed to process complex fluids such as human saliva without clogging. Furthermore, a droplet-based liquid-liquid extraction system which transfers the cocaine continuously from human saliva to the organic solvent PCE was established. For these liquids the developed system yielded a two to three times higher extraction efficiency than state-of-the-art devices. In addition, we demonstrated that our system has the potential for cocaine preconcentration in PCE, which is crucial for IR spectroscopy, our final application.","SAMLAB"]},{"key":"dc:title","label":"Title","values":["Integrated Microfluidic Liquid-Liquid Extraction for Cocaine Detection in Human Saliva"]}]}],"canonical_facts":{"dc:contributor":["Rooij, Nicolaas Frans de","Homsy, Alexandra"],"dc:creator":["Wägli, Philip"],"dc:date":["2012-12-05T15:08:45","2012-12-05","2012","2026-08-12T18:29:50.603246Z"],"dc:description":["On-site drug testing using easily accessible body fluids, such as saliva, has gained a lot of importance both for road safety and forensic applications. However, saliva is a complex, inhomogeneous amalgam with many different compounds, whose concentrations change between people and over time. This leads to a wide range of fluid properties, e.g., viscosity, surface tension, making saliva pretreatment in microfluidic systems extremely challenging. We present the development, fabrication and characterization of a low-cost, portable microsystem to detect cocaine in human saliva. The chip combines multiphase liquid-liquid extraction to transfer the cocaine from the infrared (IR) light absorbing saliva to the IR-transparent solvent, perchloroethylene (PCE), together with on-chip cocaine detection by IR-spectroscopy (IR-laser, waveguide, detector). This miniaturized sensing platform has been developed as part of the Nano-Tera project IrSens. Saliva is a suitable matrix for the analysis of small molecules such as cocaine, but it is found to be a challenge to process this complex fluid on a microfluidic chip due to the risk of clogging. The characterization of the rheological behavior of saliva is described and then a suitable sample pretreatment method is presented. The low-cost UV-curable polymer NOA81 was chosen as microfluidic chip material and characterized for microfluidic applications. For research applications a new, highly flexible, and low-cost NOA81 rapid prototyping method is presented based on scotch-tape masters. Furthermore, this thesis introduces a microfluidic chip design combining a simple and robust droplet generation method together with a geometry for droplet merging in order to perform continuous droplet-based liquid-liquid extraction. The extraction efficiency of the system was evaluated by state-of-the-art mass spectrometry measurements. The microfluidic chip has been integrated in an optofluidic microsystem transferring cocaine from human saliva to the IR-transparent organic solvent PCE and thereby enabling cocaine detection by IR-spectroscopy. In this thesis we achieved to develop a simple and robust droplet generation method re- sulting in precise and controlled droplet sizes, and which allowed to process complex fluids such as human saliva without clogging. Furthermore, a droplet-based liquid-liquid extraction system which transfers the cocaine continuously from human saliva to the organic solvent PCE was established. For these liquids the developed system yielded a two to three times higher extraction efficiency than state-of-the-art devices. In addition, we demonstrated that our system has the potential for cocaine preconcentration in PCE, which is crucial for IR spectroscopy, our final application.","SAMLAB"],"dc:identifier":["10.5075/epfl-thesis-5589","https://infoscience.epfl.ch/handle/20.500.14299/87285","urn:nbn:ch:bel-epfl-thesis5589-6"],"dc:language":["eng"],"dc:publisher":["EPFL","Lausanne"],"dc:subject":["microfluidic","saliva","cocaine","UV-curable adhesive NOA81","rapid prototyping","continuous liquid-liquid extraction","droplet generation","droplet coalescence","IR-spectroscopy"],"dc:title":["Integrated Microfluidic Liquid-Liquid Extraction for Cocaine Detection in Human Saliva"],"dc:type":["doctoral thesis"]},"updated_at":"2026-11-26T13:50:21Z"}