{"id":{"repo_id":"epfl","oai_identifier":"oai:infoscience.tind.io:231707"},"canonical_url":"https://search.ndltd.org/etd/epfl/oai:infoscience.tind.io:231707","repository":{"repo_id":"epfl","name":"EPFL","base_url":"https://infoscience.epfl.ch/server/oai/openaire4"},"display":{"title":"Resonant structures for vapor-cell atomic clocks","abstract":"Vapor-cell atomic clocks based on double resonance are high-precision instruments that have strong potential for industrial commercialization. They offer performance which is superior to quartz oscillators and are already employed for synchronization-demanding applications in telecommunication and smart power grid networks. With a volume of up to few liters, these are devices compact enough to qualify for space applications related to global positioning. Moreover, a new generation of high-performance vapor-cell clocks based on Pulsed Optical Pumping scheme (POP) showed performance approaching that of much larger frequency standards. For the case of the pulsed clock, the magnetic field homogeneity plays a central role in limiting the performance -- in order to fully exploit the advantages of the novel POP scheme it is critical to apply a constant (amplitude) field distribution across the atomic sample. The main objective of the thesis is to find and characterize a cavity solution that is appropriate to apply in compact high-performance vapor-cell atomic clocks, and more particularly in the case of the pulsed optically pumped scheme. In the currently existing solutions a relatively large type of cavity is utilized for which in order to obtain field homogeneity a small fraction of the field is sampled. A major drawback of this approach is the negatively affected compactness. Moreover, such a cavity is more restrictive to the useful volume of the atomic sample, and it is more complicated to stabilize in terms of temperature. We propose a solution for which we managed to obtain a nearly constant microwave magnetic field distribution along the direction of the optical field with more than 97\\% of orientation uniformity across the atomic sample. Our approach is to implement a cavity with artificial magnetic conductor boundary conditions in order to take advantage of a beneficial field mode with two zero variation indexes.","abstract_html":"Vapor-cell atomic clocks based on double resonance are high-precision instruments that have strong potential for industrial commercialization. They offer performance which is superior to quartz oscillators and are already employed for synchronization-demanding applications in telecommunication and smart power grid networks. With a volume of up to few liters, these are devices compact enough to qualify for space applications related to global positioning. Moreover, a new generation of high-performance vapor-cell clocks based on Pulsed Optical Pumping scheme (POP) showed performance approaching that of much larger frequency standards. For the case of the pulsed clock, the magnetic field homogeneity plays a central role in limiting the performance -- in order to fully exploit the advantages of the novel POP scheme it is critical to apply a constant (amplitude) field distribution across the atomic sample. The main objective of the thesis is to find and characterize a cavity solution that is appropriate to apply in compact high-performance vapor-cell atomic clocks, and more particularly in the case of the pulsed optically pumped scheme. In the currently existing solutions a relatively large type of cavity is utilized for which in order to obtain field homogeneity a small fraction of the field is sampled. A major drawback of this approach is the negatively affected compactness. Moreover, such a cavity is more restrictive to the useful volume of the atomic sample, and it is more complicated to stabilize in terms of temperature. We propose a solution for which we managed to obtain a nearly constant microwave magnetic field distribution along the direction of the optical field with more than 97\\% of orientation uniformity across the atomic sample. Our approach is to implement a cavity with artificial magnetic conductor boundary conditions in order to take advantage of a beneficial field mode with two zero variation indexes.","abstract_has_math":false,"creators":["Ivanov, Anton Evgeniev"],"institution":"EPFL","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Skrivervik Favre, Anja"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-10-09T17:07:59","date_published":"2017-10-09T17:07:59","updated_at":"2026-11-26T13:52:15Z","subjects":["double resonance atomic clocks","high-performance frequency standards","microwave cavities","homogeneous magnetic field distribution","artificial magnetic conductor boundary conditions"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://infoscience.epfl.ch/handle/20.500.14299/141323","urn:nbn:ch:bel-epfl-thesis7859-7"],"render_values":[{"text":"https://infoscience.epfl.ch/handle/20.500.14299/141323","href":"https://infoscience.epfl.ch/handle/20.500.14299/141323","code":true},{"text":"urn:nbn:ch:bel-epfl-thesis7859-7","href":"https://nbn-resolving.org/urn:nbn:ch:bel-epfl-thesis7859-7","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.5075/epfl-thesis-7859","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.5075/epfl-thesis-7859","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aepfl%3Aoai%3Ainfoscience.tind.io%3A231707","prefix":"oai_dc"},"source_record":{"url":"https://infoscience.epfl.ch/server/oai/openaire4?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ainfoscience.tind.io%3A231707","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Skrivervik Favre, Anja"]},{"key":"dc:creator","label":"Author","values":["Ivanov, Anton Evgeniev"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-10-09T17:07:59","2017-10-09","2017","2026-10-15T17:48:11.953928Z"]},{"key":"dc:publisher","label":"Institution","values":["EPFL","Lausanne"]},{"key":"dc:type","label":"Dc Type","values":["doctoral thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["double resonance atomic clocks","high-performance frequency standards","microwave cavities","homogeneous magnetic field distribution","artificial magnetic conductor boundary conditions"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.5075/epfl-thesis-7859","https://infoscience.epfl.ch/handle/20.500.14299/141323","urn:nbn:ch:bel-epfl-thesis7859-7"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Vapor-cell atomic clocks based on double resonance are high-precision instruments that have strong potential for industrial commercialization. They offer performance which is superior to quartz oscillators and are already employed for synchronization-demanding applications in telecommunication and smart power grid networks. With a volume of up to few liters, these are devices compact enough to qualify for space applications related to global positioning. Moreover, a new generation of high-performance vapor-cell clocks based on Pulsed Optical Pumping scheme (POP) showed performance approaching that of much larger frequency standards. For the case of the pulsed clock, the magnetic field homogeneity plays a central role in limiting the performance -- in order to fully exploit the advantages of the novel POP scheme it is critical to apply a constant (amplitude) field distribution across the atomic sample. The main objective of the thesis is to find and characterize a cavity solution that is appropriate to apply in compact high-performance vapor-cell atomic clocks, and more particularly in the case of the pulsed optically pumped scheme. In the currently existing solutions a relatively large type of cavity is utilized for which in order to obtain field homogeneity a small fraction of the field is sampled. A major drawback of this approach is the negatively affected compactness. Moreover, such a cavity is more restrictive to the useful volume of the atomic sample, and it is more complicated to stabilize in terms of temperature. We propose a solution for which we managed to obtain a nearly constant microwave magnetic field distribution along the direction of the optical field with more than 97\\% of orientation uniformity across the atomic sample. Our approach is to implement a cavity with artificial magnetic conductor boundary conditions in order to take advantage of a beneficial field mode with two zero variation indexes.","LEMA"]},{"key":"dc:title","label":"Title","values":["Resonant structures for vapor-cell atomic clocks"]}]}],"canonical_facts":{"dc:contributor":["Skrivervik Favre, Anja"],"dc:creator":["Ivanov, Anton Evgeniev"],"dc:date":["2017-10-09T17:07:59","2017-10-09","2017","2026-10-15T17:48:11.953928Z"],"dc:description":["Vapor-cell atomic clocks based on double resonance are high-precision instruments that have strong potential for industrial commercialization. They offer performance which is superior to quartz oscillators and are already employed for synchronization-demanding applications in telecommunication and smart power grid networks. With a volume of up to few liters, these are devices compact enough to qualify for space applications related to global positioning. Moreover, a new generation of high-performance vapor-cell clocks based on Pulsed Optical Pumping scheme (POP) showed performance approaching that of much larger frequency standards. For the case of the pulsed clock, the magnetic field homogeneity plays a central role in limiting the performance -- in order to fully exploit the advantages of the novel POP scheme it is critical to apply a constant (amplitude) field distribution across the atomic sample. The main objective of the thesis is to find and characterize a cavity solution that is appropriate to apply in compact high-performance vapor-cell atomic clocks, and more particularly in the case of the pulsed optically pumped scheme. In the currently existing solutions a relatively large type of cavity is utilized for which in order to obtain field homogeneity a small fraction of the field is sampled. A major drawback of this approach is the negatively affected compactness. Moreover, such a cavity is more restrictive to the useful volume of the atomic sample, and it is more complicated to stabilize in terms of temperature. We propose a solution for which we managed to obtain a nearly constant microwave magnetic field distribution along the direction of the optical field with more than 97\\% of orientation uniformity across the atomic sample. Our approach is to implement a cavity with artificial magnetic conductor boundary conditions in order to take advantage of a beneficial field mode with two zero variation indexes.","LEMA"],"dc:identifier":["10.5075/epfl-thesis-7859","https://infoscience.epfl.ch/handle/20.500.14299/141323","urn:nbn:ch:bel-epfl-thesis7859-7"],"dc:language":["eng"],"dc:publisher":["EPFL","Lausanne"],"dc:subject":["double resonance atomic clocks","high-performance frequency standards","microwave cavities","homogeneous magnetic field distribution","artificial magnetic conductor boundary conditions"],"dc:title":["Resonant structures for vapor-cell atomic clocks"],"dc:type":["doctoral thesis"]},"updated_at":"2026-11-26T13:52:15Z"}