{"id":{"repo_id":"ets-quebec","oai_identifier":"oai:espace.etsmtl.ca:1695"},"canonical_url":"https://search.ndltd.org/etd/ets-quebec/oai:espace.etsmtl.ca:1695","repository":{"repo_id":"ets-quebec","name":"ETS (Quebec)","base_url":"https://espace.etsmtl.ca/cgi/oai2"},"display":{"title":"An impedance based method for distribution system monitoring","abstract":"The main goal of this thesis is to propose a new monitoring technique for traditional distribution system with integration of renewable energy source. The traditional distribution network is primarily composed of radial feeders, designed for unidirectional power flow. Therefore, many operation regulation, protection and control system, in distribution network, are based on the radial distribution systems assumption. The high penetration of the renewable energy sources, will clearly impact the distribution systems operation. Unlike other ways of electricity generation renewable energies initiate some challenges for grid operation. Intermittency of renewable energies sources, power system protection, stability, security, economic dispatch, optimal power flow are critical issues initiated by renewable energies penetration to power systems. In addition, the renewable energy source output may exceed the consumed power during the day. Therefore, the direction of the power flow can be reversed during some periods. The high penetration of decentralized renewable sources will create a multidirectional power flow condition in the distribution grid, which was originally designed for unidirectional power flow only. Following of this reverse power flow, the distribution feeder voltage rises. In this thesis the necessity of online monitoring system for important feeders in distribution system will be shown. It will be shown that the apparent impedance measured on the feeder has great capabilities for on line monitoring of distribution feeder. The thesis establishes the steady-state mathematical model for defining the monitoring zone in R-X plane as the main contribution. It will be shown that the apparent impedance has a good potential for monitoring of feeder power factor, reverse and forward active and reactive power flow. In addition, it will be shown that complex power curve can be transferred to R-X plane to monitor the reactive power requirement regulation issued by utilities for RES integration.","abstract_html":"The main goal of this thesis is to propose a new monitoring technique for traditional distribution system with integration of renewable energy source. The traditional distribution network is primarily composed of radial feeders, designed for unidirectional power flow. Therefore, many operation regulation, protection and control system, in distribution network, are based on the radial distribution systems assumption. The high penetration of the renewable energy sources, will clearly impact the distribution systems operation. Unlike other ways of electricity generation renewable energies initiate some challenges for grid operation. Intermittency of renewable energies sources, power system protection, stability, security, economic dispatch, optimal power flow are critical issues initiated by renewable energies penetration to power systems. In addition, the renewable energy source output may exceed the consumed power during the day. Therefore, the direction of the power flow can be reversed during some periods. The high penetration of decentralized renewable sources will create a multidirectional power flow condition in the distribution grid, which was originally designed for unidirectional power flow only. Following of this reverse power flow, the distribution feeder voltage rises. In this thesis the necessity of online monitoring system for important feeders in distribution system will be shown. It will be shown that the apparent impedance measured on the feeder has great capabilities for on line monitoring of distribution feeder. The thesis establishes the steady-state mathematical model for defining the monitoring zone in R-X plane as the main contribution. It will be shown that the apparent impedance has a good potential for monitoring of feeder power factor, reverse and forward active and reactive power flow. In addition, it will be shown that complex power curve can be transferred to R-X plane to monitor the reactive power requirement regulation issued by utilities for RES integration.","abstract_has_math":false,"creators":["Mortazavi, Hashem"],"institution":"École de technologie supérieure","degree_name":"Thèse de doctorat électronique","degree_level":"phd","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-04-01","date_published":"2016-04-01","updated_at":"2026-11-18T22:07:07Z","subjects":["Électricité Distribution. Alimentation en énergie électrique. Énergies renouvelables. Impédance électrique. Facteur de puissance (Électricité) flux, puissance, calcul d'impédance, sources d'énergie renouvelables, système de distribution, surveillance"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE1695"],"render_values":[{"text":"INSERT-YOUR-LIBRARY-ID-HERE1695","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://espace.etsmtl.ca/id/eprint/1695/1/MORTAZAVI_Hashem.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://espace.etsmtl.ca/cgi/oai2?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aespace.etsmtl.ca%3A1695","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Mortazavi, Hashem"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-04-01"]},{"key":"dc:publisher","label":"Institution","values":["École de technologie supérieure"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["phd"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Thèse de doctorat électronique"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["École de technologie supérieure"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Électricité Distribution. Alimentation en énergie électrique. Énergies renouvelables. Impédance électrique. Facteur de puissance (Électricité) flux, puissance, calcul d'impédance, sources d'énergie renouvelables, système de distribution, surveillance"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE1695","https://espace.etsmtl.ca/id/eprint/1695/1/MORTAZAVI_Hashem.pdf","https://espace.etsmtl.ca/id/eprint/1695/2/MORTAZAVI_Hashem-web.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The main goal of this thesis is to propose a new monitoring technique for traditional distribution system with integration of renewable energy source. The traditional distribution network is primarily composed of radial feeders, designed for unidirectional power flow. Therefore, many operation regulation, protection and control system, in distribution network, are based on the radial distribution systems assumption. The high penetration of the renewable energy sources, will clearly impact the distribution systems operation. Unlike other ways of electricity generation renewable energies initiate some challenges for grid operation. Intermittency of renewable energies sources, power system protection, stability, security, economic dispatch, optimal power flow are critical issues initiated by renewable energies penetration to power systems. In addition, the renewable energy source output may exceed the consumed power during the day. Therefore, the direction of the power flow can be reversed during some periods. The high penetration of decentralized renewable sources will create a multidirectional power flow condition in the distribution grid, which was originally designed for unidirectional power flow only. Following of this reverse power flow, the distribution feeder voltage rises. In this thesis the necessity of online monitoring system for important feeders in distribution system will be shown. It will be shown that the apparent impedance measured on the feeder has great capabilities for on line monitoring of distribution feeder. The thesis establishes the steady-state mathematical model for defining the monitoring zone in R-X plane as the main contribution. It will be shown that the apparent impedance has a good potential for monitoring of feeder power factor, reverse and forward active and reactive power flow. In addition, it will be shown that complex power curve can be transferred to R-X plane to monitor the reactive power requirement regulation issued by utilities for RES integration."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["An impedance based method for distribution system monitoring"]}]}],"canonical_facts":{"dc:creator":["Mortazavi, Hashem"],"dc:date":["2016-04-01"],"dc:description":["The main goal of this thesis is to propose a new monitoring technique for traditional distribution system with integration of renewable energy source. The traditional distribution network is primarily composed of radial feeders, designed for unidirectional power flow. Therefore, many operation regulation, protection and control system, in distribution network, are based on the radial distribution systems assumption. The high penetration of the renewable energy sources, will clearly impact the distribution systems operation. Unlike other ways of electricity generation renewable energies initiate some challenges for grid operation. Intermittency of renewable energies sources, power system protection, stability, security, economic dispatch, optimal power flow are critical issues initiated by renewable energies penetration to power systems. In addition, the renewable energy source output may exceed the consumed power during the day. Therefore, the direction of the power flow can be reversed during some periods. The high penetration of decentralized renewable sources will create a multidirectional power flow condition in the distribution grid, which was originally designed for unidirectional power flow only. Following of this reverse power flow, the distribution feeder voltage rises. In this thesis the necessity of online monitoring system for important feeders in distribution system will be shown. It will be shown that the apparent impedance measured on the feeder has great capabilities for on line monitoring of distribution feeder. The thesis establishes the steady-state mathematical model for defining the monitoring zone in R-X plane as the main contribution. It will be shown that the apparent impedance has a good potential for monitoring of feeder power factor, reverse and forward active and reactive power flow. In addition, it will be shown that complex power curve can be transferred to R-X plane to monitor the reactive power requirement regulation issued by utilities for RES integration."],"dc:format":["application/pdf"],"dc:identifier":["INSERT-YOUR-LIBRARY-ID-HERE1695","https://espace.etsmtl.ca/id/eprint/1695/1/MORTAZAVI_Hashem.pdf","https://espace.etsmtl.ca/id/eprint/1695/2/MORTAZAVI_Hashem-web.pdf"],"dc:language":["en"],"dc:publisher":["École de technologie supérieure"],"dc:subject":["Électricité Distribution. Alimentation en énergie électrique. Énergies renouvelables. Impédance électrique. Facteur de puissance (Électricité) flux, puissance, calcul d'impédance, sources d'énergie renouvelables, système de distribution, surveillance"],"dc:title":["An impedance based method for distribution system monitoring"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_level":["phd"],"thesis:degree_name":["Thèse de doctorat électronique"],"thesis:institution_name":["École de technologie supérieure"]},"updated_at":"2026-11-18T22:07:07Z"}