{"id":{"repo_id":"ets-quebec","oai_identifier":"oai:espace.etsmtl.ca:2069"},"canonical_url":"https://search.ndltd.org/etd/ets-quebec/oai:espace.etsmtl.ca:2069","repository":{"repo_id":"ets-quebec","name":"ETS (Quebec)","base_url":"https://espace.etsmtl.ca/cgi/oai2"},"display":{"title":"3D reconstruction of coronary artery using Feldkamp-Davis-Kress algorithm","abstract":"An important cause of death in industrialized countries is coronary heart diseases. To treat those pathologies, a percutaneous intervention that consists in inserting a catheter in the femoral artery is performed. The instrument is directed to the affected arteries, and coronary angiography is used to lead the surgeon in an interventional context. However, 2D angiography which is frequently used during an intervention, does not consider depth, resulting in high doses of contrast agent and an extended exposure to X-ray. To mitigate the impact of these problems, medical imaging techniques such as 3D coronary artery imaging are used to assist surgeons during the intervention. Many imaging modalities are used to acquire the sequences, but the rotational angiography is favored due to its lower contrast agent use and its ease of use in an interventional context. This imaging technique allows the surgeon to guide the catheter in 3D in a clear manner, and limit the use of X-rays and contrast agent by reducing the duration of the intervention. In this thesis, we present a flexible algorithm, Feldkamp-Davis-Kress (FDK), to reconstruct 3D model of coronary artery in multiple angle views. The dual-axis rotational coronary artery angiography is proposed to use along with this algorithm. The cameras parameters are first calibrated by a nonlinear optimization where the reprojection error is minimized. Then the optimal working view is calculated to avoiding the vessel overlap and foreshortening effects. To reduce the cardiac motion effect, ECG-gated is applied into the reconstruction algorithm. The proposed method can be used in the framework to improve 3D navigation guidance in surgery. It could be a good tool for clinicians in coronary artery disease.","abstract_html":"An important cause of death in industrialized countries is coronary heart diseases. To treat those pathologies, a percutaneous intervention that consists in inserting a catheter in the femoral artery is performed. The instrument is directed to the affected arteries, and coronary angiography is used to lead the surgeon in an interventional context. However, 2D angiography which is frequently used during an intervention, does not consider depth, resulting in high doses of contrast agent and an extended exposure to X-ray. To mitigate the impact of these problems, medical imaging techniques such as 3D coronary artery imaging are used to assist surgeons during the intervention. Many imaging modalities are used to acquire the sequences, but the rotational angiography is favored due to its lower contrast agent use and its ease of use in an interventional context. This imaging technique allows the surgeon to guide the catheter in 3D in a clear manner, and limit the use of X-rays and contrast agent by reducing the duration of the intervention. In this thesis, we present a flexible algorithm, Feldkamp-Davis-Kress (FDK), to reconstruct 3D model of coronary artery in multiple angle views. The dual-axis rotational coronary artery angiography is proposed to use along with this algorithm. The cameras parameters are first calibrated by a nonlinear optimization where the reprojection error is minimized. Then the optimal working view is calculated to avoiding the vessel overlap and foreshortening effects. To reduce the cardiac motion effect, ECG-gated is applied into the reconstruction algorithm. The proposed method can be used in the framework to improve 3D navigation guidance in surgery. It could be a good tool for clinicians in coronary artery disease.","abstract_has_math":false,"creators":["Tran, Phan Binh"],"institution":"École de technologie supérieure","degree_name":"Mémoire de maîtrise électronique","degree_level":"masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-11-01","date_published":"2017-11-01","updated_at":"2026-11-18T22:07:41Z","subjects":["Angiographie numérique. Artères coronaires Radiographie. Tomographie volumique à faisceau conique. Modélisation tridimensionnelle. Imagerie tridimensionnelle en médecine. fdk, reconstruction 3D, signal ECG, rétroprojection, mouvement cardiorespiratoire, reconstruction tomographique"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE2069"],"render_values":[{"text":"INSERT-YOUR-LIBRARY-ID-HERE2069","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://espace.etsmtl.ca/id/eprint/2069/1/TRAN_Phan_Binh.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://espace.etsmtl.ca/cgi/oai2?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aespace.etsmtl.ca%3A2069","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Tran, Phan Binh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-11-01"]},{"key":"dc:publisher","label":"Institution","values":["École de technologie supérieure"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Mémoire de maîtrise électronique"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["École de technologie supérieure"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Angiographie numérique. Artères coronaires Radiographie. Tomographie volumique à faisceau conique. Modélisation tridimensionnelle. Imagerie tridimensionnelle en médecine. fdk, reconstruction 3D, signal ECG, rétroprojection, mouvement cardiorespiratoire, reconstruction tomographique"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE2069","https://espace.etsmtl.ca/id/eprint/2069/1/TRAN_Phan_Binh.pdf","https://espace.etsmtl.ca/id/eprint/2069/2/TRAN_Phan_Binh-web.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["An important cause of death in industrialized countries is coronary heart diseases. To treat those pathologies, a percutaneous intervention that consists in inserting a catheter in the femoral artery is performed. The instrument is directed to the affected arteries, and coronary angiography is used to lead the surgeon in an interventional context. However, 2D angiography which is frequently used during an intervention, does not consider depth, resulting in high doses of contrast agent and an extended exposure to X-ray. To mitigate the impact of these problems, medical imaging techniques such as 3D coronary artery imaging are used to assist surgeons during the intervention. Many imaging modalities are used to acquire the sequences, but the rotational angiography is favored due to its lower contrast agent use and its ease of use in an interventional context. This imaging technique allows the surgeon to guide the catheter in 3D in a clear manner, and limit the use of X-rays and contrast agent by reducing the duration of the intervention. In this thesis, we present a flexible algorithm, Feldkamp-Davis-Kress (FDK), to reconstruct 3D model of coronary artery in multiple angle views. The dual-axis rotational coronary artery angiography is proposed to use along with this algorithm. The cameras parameters are first calibrated by a nonlinear optimization where the reprojection error is minimized. Then the optimal working view is calculated to avoiding the vessel overlap and foreshortening effects. To reduce the cardiac motion effect, ECG-gated is applied into the reconstruction algorithm. The proposed method can be used in the framework to improve 3D navigation guidance in surgery. It could be a good tool for clinicians in coronary artery disease."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["3D reconstruction of coronary artery using Feldkamp-Davis-Kress algorithm"]}]}],"canonical_facts":{"dc:creator":["Tran, Phan Binh"],"dc:date":["2017-11-01"],"dc:description":["An important cause of death in industrialized countries is coronary heart diseases. To treat those pathologies, a percutaneous intervention that consists in inserting a catheter in the femoral artery is performed. The instrument is directed to the affected arteries, and coronary angiography is used to lead the surgeon in an interventional context. However, 2D angiography which is frequently used during an intervention, does not consider depth, resulting in high doses of contrast agent and an extended exposure to X-ray. To mitigate the impact of these problems, medical imaging techniques such as 3D coronary artery imaging are used to assist surgeons during the intervention. Many imaging modalities are used to acquire the sequences, but the rotational angiography is favored due to its lower contrast agent use and its ease of use in an interventional context. This imaging technique allows the surgeon to guide the catheter in 3D in a clear manner, and limit the use of X-rays and contrast agent by reducing the duration of the intervention. In this thesis, we present a flexible algorithm, Feldkamp-Davis-Kress (FDK), to reconstruct 3D model of coronary artery in multiple angle views. The dual-axis rotational coronary artery angiography is proposed to use along with this algorithm. The cameras parameters are first calibrated by a nonlinear optimization where the reprojection error is minimized. Then the optimal working view is calculated to avoiding the vessel overlap and foreshortening effects. To reduce the cardiac motion effect, ECG-gated is applied into the reconstruction algorithm. The proposed method can be used in the framework to improve 3D navigation guidance in surgery. It could be a good tool for clinicians in coronary artery disease."],"dc:format":["application/pdf"],"dc:identifier":["INSERT-YOUR-LIBRARY-ID-HERE2069","https://espace.etsmtl.ca/id/eprint/2069/1/TRAN_Phan_Binh.pdf","https://espace.etsmtl.ca/id/eprint/2069/2/TRAN_Phan_Binh-web.pdf"],"dc:language":["en"],"dc:publisher":["École de technologie supérieure"],"dc:subject":["Angiographie numérique. Artères coronaires Radiographie. Tomographie volumique à faisceau conique. Modélisation tridimensionnelle. Imagerie tridimensionnelle en médecine. fdk, reconstruction 3D, signal ECG, rétroprojection, mouvement cardiorespiratoire, reconstruction tomographique"],"dc:title":["3D reconstruction of coronary artery using Feldkamp-Davis-Kress algorithm"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_level":["masters"],"thesis:degree_name":["Mémoire de maîtrise électronique"],"thesis:institution_name":["École de technologie supérieure"]},"updated_at":"2026-11-18T22:07:41Z"}