{"id":{"repo_id":"ets-quebec","oai_identifier":"oai:espace.etsmtl.ca:2713"},"canonical_url":"https://search.ndltd.org/etd/ets-quebec/oai:espace.etsmtl.ca:2713","repository":{"repo_id":"ets-quebec","name":"ETS (Quebec)","base_url":"https://espace.etsmtl.ca/cgi/oai2"},"display":{"title":"Development and validation of the control loops for the haptic interfaces of a standard manual wheelchair simulator","abstract":"There are about 47,000 manual wheelchair (MWC) users in Quebec, and 155,000 in Canada. Research indicates that 30 to 70% of them begin feeling chronic pain in the upper limb joints within the first five years of use. To investigate this issue in the laboratory, our team has developed a manual wheelchair simulator that uses instrumented wheels as force sensors. These wheels replace the wheelchair’s original wheels, thus limiting the degree of realism of the simulator. The objective of this work was to increase this degree of realism, by replacing the force sensors used currently. To this effect, a six-axes force cell was placed underneath the wheelchair. An admittance control loop was developed to control the moment-velocity interaction of the wheelchair’s rear wheels. Data gathering was conducted with one healthy subject to evaluate the level of realism of wheelchair propulsion. On both sides, maximum propulsive moments Mzmax (Nm), maximum applied force FTOTmax (N), push time PT (s) and recovery time RT (s) were calculated and compared between three conditions: on the ground (OG), on the simulator controlled by the instrumented wheels (SW) and on the simulator controlled by the force cell (FC). Results confirm the research hypotheses: the control loop is stable, meaning that the real speed follows the desired speed. Comparison of biomechanical parameters is as follows: regarding Mzmax, the difference between conditions OG and FC is small, whereas that between OG and SW is large. With regards to FTOTmax and TP, differences between OG and FC, and between OG and SW are both large. For TR, differences between OG and FC and between OG and SW are both small. In conclusion, it seems that propulsion on the simulator controlled by a force cell may be slightly closer to propulsion on the ground than that on a simulator controlled by instrumented wheels. This could be explained by the fact that the movement of the trunk of the user affects the dynamics of the wheelchair-user system. This effect is captured by the force cell, but not by the Smartwheels.","abstract_html":"There are about 47,000 manual wheelchair (MWC) users in Quebec, and 155,000 in Canada. Research indicates that 30 to 70% of them begin feeling chronic pain in the upper limb joints within the first five years of use. To investigate this issue in the laboratory, our team has developed a manual wheelchair simulator that uses instrumented wheels as force sensors. These wheels replace the wheelchair’s original wheels, thus limiting the degree of realism of the simulator. The objective of this work was to increase this degree of realism, by replacing the force sensors used currently. To this effect, a six-axes force cell was placed underneath the wheelchair. An admittance control loop was developed to control the moment-velocity interaction of the wheelchair’s rear wheels. Data gathering was conducted with one healthy subject to evaluate the level of realism of wheelchair propulsion. On both sides, maximum propulsive moments Mzmax (Nm), maximum applied force FTOTmax (N), push time PT (s) and recovery time RT (s) were calculated and compared between three conditions: on the ground (OG), on the simulator controlled by the instrumented wheels (SW) and on the simulator controlled by the force cell (FC). Results confirm the research hypotheses: the control loop is stable, meaning that the real speed follows the desired speed. Comparison of biomechanical parameters is as follows: regarding Mzmax, the difference between conditions OG and FC is small, whereas that between OG and SW is large. With regards to FTOTmax and TP, differences between OG and FC, and between OG and SW are both large. For TR, differences between OG and FC and between OG and SW are both small. In conclusion, it seems that propulsion on the simulator controlled by a force cell may be slightly closer to propulsion on the ground than that on a simulator controlled by instrumented wheels. This could be explained by the fact that the movement of the trunk of the user affects the dynamics of the wheelchair-user system. This effect is captured by the force cell, but not by the Smartwheels.","abstract_has_math":false,"creators":["Pizarro-Chong, Ary Druva"],"institution":"École de technologie supérieure","degree_name":"Mémoire de maîtrise électronique","degree_level":"masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-01-05","date_published":"2021-01-05","updated_at":"2026-11-18T22:08:52Z","subjects":["robotique de la réadaptation, interface haptique, fauteuil roulant, simulateur"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE2713"],"render_values":[{"text":"INSERT-YOUR-LIBRARY-ID-HERE2713","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://espace.etsmtl.ca/id/eprint/2713/1/PIZARRO_CHONG_Ary_Druva.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://espace.etsmtl.ca/cgi/oai2?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aespace.etsmtl.ca%3A2713","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Pizarro-Chong, Ary Druva"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-01-05"]},{"key":"dc:publisher","label":"Institution","values":["École de technologie supérieure"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Mémoire de maîtrise électronique"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["École de technologie supérieure"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["robotique de la réadaptation, interface haptique, fauteuil roulant, simulateur"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE2713","https://espace.etsmtl.ca/id/eprint/2713/1/PIZARRO_CHONG_Ary_Druva.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["There are about 47,000 manual wheelchair (MWC) users in Quebec, and 155,000 in Canada. Research indicates that 30 to 70% of them begin feeling chronic pain in the upper limb joints within the first five years of use. To investigate this issue in the laboratory, our team has developed a manual wheelchair simulator that uses instrumented wheels as force sensors. These wheels replace the wheelchair’s original wheels, thus limiting the degree of realism of the simulator. The objective of this work was to increase this degree of realism, by replacing the force sensors used currently. To this effect, a six-axes force cell was placed underneath the wheelchair. An admittance control loop was developed to control the moment-velocity interaction of the wheelchair’s rear wheels. Data gathering was conducted with one healthy subject to evaluate the level of realism of wheelchair propulsion. On both sides, maximum propulsive moments Mzmax (Nm), maximum applied force FTOTmax (N), push time PT (s) and recovery time RT (s) were calculated and compared between three conditions: on the ground (OG), on the simulator controlled by the instrumented wheels (SW) and on the simulator controlled by the force cell (FC). Results confirm the research hypotheses: the control loop is stable, meaning that the real speed follows the desired speed. Comparison of biomechanical parameters is as follows: regarding Mzmax, the difference between conditions OG and FC is small, whereas that between OG and SW is large. With regards to FTOTmax and TP, differences between OG and FC, and between OG and SW are both large. For TR, differences between OG and FC and between OG and SW are both small. In conclusion, it seems that propulsion on the simulator controlled by a force cell may be slightly closer to propulsion on the ground than that on a simulator controlled by instrumented wheels. This could be explained by the fact that the movement of the trunk of the user affects the dynamics of the wheelchair-user system. This effect is captured by the force cell, but not by the Smartwheels."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development and validation of the control loops for the haptic interfaces of a standard manual wheelchair simulator"]}]}],"canonical_facts":{"dc:creator":["Pizarro-Chong, Ary Druva"],"dc:date":["2021-01-05"],"dc:description":["There are about 47,000 manual wheelchair (MWC) users in Quebec, and 155,000 in Canada. Research indicates that 30 to 70% of them begin feeling chronic pain in the upper limb joints within the first five years of use. To investigate this issue in the laboratory, our team has developed a manual wheelchair simulator that uses instrumented wheels as force sensors. These wheels replace the wheelchair’s original wheels, thus limiting the degree of realism of the simulator. The objective of this work was to increase this degree of realism, by replacing the force sensors used currently. To this effect, a six-axes force cell was placed underneath the wheelchair. An admittance control loop was developed to control the moment-velocity interaction of the wheelchair’s rear wheels. Data gathering was conducted with one healthy subject to evaluate the level of realism of wheelchair propulsion. On both sides, maximum propulsive moments Mzmax (Nm), maximum applied force FTOTmax (N), push time PT (s) and recovery time RT (s) were calculated and compared between three conditions: on the ground (OG), on the simulator controlled by the instrumented wheels (SW) and on the simulator controlled by the force cell (FC). Results confirm the research hypotheses: the control loop is stable, meaning that the real speed follows the desired speed. Comparison of biomechanical parameters is as follows: regarding Mzmax, the difference between conditions OG and FC is small, whereas that between OG and SW is large. With regards to FTOTmax and TP, differences between OG and FC, and between OG and SW are both large. For TR, differences between OG and FC and between OG and SW are both small. In conclusion, it seems that propulsion on the simulator controlled by a force cell may be slightly closer to propulsion on the ground than that on a simulator controlled by instrumented wheels. This could be explained by the fact that the movement of the trunk of the user affects the dynamics of the wheelchair-user system. This effect is captured by the force cell, but not by the Smartwheels."],"dc:format":["application/pdf"],"dc:identifier":["INSERT-YOUR-LIBRARY-ID-HERE2713","https://espace.etsmtl.ca/id/eprint/2713/1/PIZARRO_CHONG_Ary_Druva.pdf"],"dc:language":["en"],"dc:publisher":["École de technologie supérieure"],"dc:subject":["robotique de la réadaptation, interface haptique, fauteuil roulant, simulateur"],"dc:title":["Development and validation of the control loops for the haptic interfaces of a standard manual wheelchair simulator"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_level":["masters"],"thesis:degree_name":["Mémoire de maîtrise électronique"],"thesis:institution_name":["École de technologie supérieure"]},"updated_at":"2026-11-18T22:08:52Z"}