{"id":{"repo_id":"ets-quebec","oai_identifier":"oai:espace.etsmtl.ca:2747"},"canonical_url":"https://search.ndltd.org/etd/ets-quebec/oai:espace.etsmtl.ca:2747","repository":{"repo_id":"ets-quebec","name":"ETS (Quebec)","base_url":"https://espace.etsmtl.ca/cgi/oai2"},"display":{"title":"A fast signal quality assessment algorithm applied to a contactless electrocardiogram system","abstract":"Signal quality assessment (SQA), or noise detector systems, promise to improve the quality of the collected electrocardiogram (ECG). This is achieved by enabling automated systems to accurately collect and process ECG data, or facilitating telemetry through the accurate selection of acceptable data, in order to be analyzed remotely by a cardiologist. This thesis is a research & development (R&D) collaboration with SIG.NUM, a company that is specialized in the development and commercialization of an innovative proprietary contactless and automated technology for both short and long term ECG acquisition, known as cECG. This work presents fundamentals regarding different ECG instrumentation systems; a review about SQA, its fundaments and applications to cECG systems; a review about wavelets and its applications regarding ECG signal representation; and finally, the design of an SQA classifier system, or noise detector, using artificial neural networks (ANN), and wavelet scalogram-based fast signal processing techniques for feature extraction purposes. The SQA classifier system is meant to be used as a real-time channel selector for the cECG system developed by SIG.NUM. The developed machine learning based algorithm for ECG SQA is trained by a merge of several annotated data-sets, available from PhysioNet (Goldberger et al., 2000). Results of the designed system are mainly compared with the single-lead SQA technique proposed by the work of Clifford et al. (2012). In conclusion, this thesis showed that a simple shallow ANN is sufficient for well modelling a generalized SQA classifier system. Moreover, results showed that the wavelet transform feature extraction method, proposed by this thesis, is not only very powerful to represent ECG signal quality, but also computationally efficient.","abstract_html":"Signal quality assessment (SQA), or noise detector systems, promise to improve the quality of the collected electrocardiogram (ECG). This is achieved by enabling automated systems to accurately collect and process ECG data, or facilitating telemetry through the accurate selection of acceptable data, in order to be analyzed remotely by a cardiologist. This thesis is a research &amp; development (R&amp;D) collaboration with SIG.NUM, a company that is specialized in the development and commercialization of an innovative proprietary contactless and automated technology for both short and long term ECG acquisition, known as cECG. This work presents fundamentals regarding different ECG instrumentation systems; a review about SQA, its fundaments and applications to cECG systems; a review about wavelets and its applications regarding ECG signal representation; and finally, the design of an SQA classifier system, or noise detector, using artificial neural networks (ANN), and wavelet scalogram-based fast signal processing techniques for feature extraction purposes. The SQA classifier system is meant to be used as a real-time channel selector for the cECG system developed by SIG.NUM. The developed machine learning based algorithm for ECG SQA is trained by a merge of several annotated data-sets, available from PhysioNet (Goldberger et al., 2000). Results of the designed system are mainly compared with the single-lead SQA technique proposed by the work of Clifford et al. (2012). In conclusion, this thesis showed that a simple shallow ANN is sufficient for well modelling a generalized SQA classifier system. Moreover, results showed that the wavelet transform feature extraction method, proposed by this thesis, is not only very powerful to represent ECG signal quality, but also computationally efficient.","abstract_has_math":false,"creators":["Targino Lins, Lucas"],"institution":"École de technologie supérieure","degree_name":"Mémoire de maîtrise électronique","degree_level":"masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-03-24","date_published":"2021-03-24","updated_at":"2026-11-18T22:08:52Z","subjects":["ECG, évaluation de la qualité du signal, indice de qualité du signal, transformée en ondelettes rapide, apprentissage automatique, réseaux de neurones, extraction de caractéristiques"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE2747"],"render_values":[{"text":"INSERT-YOUR-LIBRARY-ID-HERE2747","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://espace.etsmtl.ca/id/eprint/2747/1/TARGINO_LINS_Lucas.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://espace.etsmtl.ca/cgi/oai2?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aespace.etsmtl.ca%3A2747","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Targino Lins, Lucas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-03-24"]},{"key":"dc:publisher","label":"Institution","values":["École de technologie supérieure"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Mémoire de maîtrise électronique"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["École de technologie supérieure"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["ECG, évaluation de la qualité du signal, indice de qualité du signal, transformée en ondelettes rapide, apprentissage automatique, réseaux de neurones, extraction de caractéristiques"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE2747","https://espace.etsmtl.ca/id/eprint/2747/1/TARGINO_LINS_Lucas.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Signal quality assessment (SQA), or noise detector systems, promise to improve the quality of the collected electrocardiogram (ECG). This is achieved by enabling automated systems to accurately collect and process ECG data, or facilitating telemetry through the accurate selection of acceptable data, in order to be analyzed remotely by a cardiologist. This thesis is a research & development (R&D) collaboration with SIG.NUM, a company that is specialized in the development and commercialization of an innovative proprietary contactless and automated technology for both short and long term ECG acquisition, known as cECG. This work presents fundamentals regarding different ECG instrumentation systems; a review about SQA, its fundaments and applications to cECG systems; a review about wavelets and its applications regarding ECG signal representation; and finally, the design of an SQA classifier system, or noise detector, using artificial neural networks (ANN), and wavelet scalogram-based fast signal processing techniques for feature extraction purposes. The SQA classifier system is meant to be used as a real-time channel selector for the cECG system developed by SIG.NUM. The developed machine learning based algorithm for ECG SQA is trained by a merge of several annotated data-sets, available from PhysioNet (Goldberger et al., 2000). Results of the designed system are mainly compared with the single-lead SQA technique proposed by the work of Clifford et al. (2012). In conclusion, this thesis showed that a simple shallow ANN is sufficient for well modelling a generalized SQA classifier system. Moreover, results showed that the wavelet transform feature extraction method, proposed by this thesis, is not only very powerful to represent ECG signal quality, but also computationally efficient."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A fast signal quality assessment algorithm applied to a contactless electrocardiogram system"]}]}],"canonical_facts":{"dc:creator":["Targino Lins, Lucas"],"dc:date":["2021-03-24"],"dc:description":["Signal quality assessment (SQA), or noise detector systems, promise to improve the quality of the collected electrocardiogram (ECG). This is achieved by enabling automated systems to accurately collect and process ECG data, or facilitating telemetry through the accurate selection of acceptable data, in order to be analyzed remotely by a cardiologist. This thesis is a research & development (R&D) collaboration with SIG.NUM, a company that is specialized in the development and commercialization of an innovative proprietary contactless and automated technology for both short and long term ECG acquisition, known as cECG. This work presents fundamentals regarding different ECG instrumentation systems; a review about SQA, its fundaments and applications to cECG systems; a review about wavelets and its applications regarding ECG signal representation; and finally, the design of an SQA classifier system, or noise detector, using artificial neural networks (ANN), and wavelet scalogram-based fast signal processing techniques for feature extraction purposes. The SQA classifier system is meant to be used as a real-time channel selector for the cECG system developed by SIG.NUM. The developed machine learning based algorithm for ECG SQA is trained by a merge of several annotated data-sets, available from PhysioNet (Goldberger et al., 2000). Results of the designed system are mainly compared with the single-lead SQA technique proposed by the work of Clifford et al. (2012). In conclusion, this thesis showed that a simple shallow ANN is sufficient for well modelling a generalized SQA classifier system. Moreover, results showed that the wavelet transform feature extraction method, proposed by this thesis, is not only very powerful to represent ECG signal quality, but also computationally efficient."],"dc:format":["application/pdf"],"dc:identifier":["INSERT-YOUR-LIBRARY-ID-HERE2747","https://espace.etsmtl.ca/id/eprint/2747/1/TARGINO_LINS_Lucas.pdf"],"dc:language":["en"],"dc:publisher":["École de technologie supérieure"],"dc:subject":["ECG, évaluation de la qualité du signal, indice de qualité du signal, transformée en ondelettes rapide, apprentissage automatique, réseaux de neurones, extraction de caractéristiques"],"dc:title":["A fast signal quality assessment algorithm applied to a contactless electrocardiogram system"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_level":["masters"],"thesis:degree_name":["Mémoire de maîtrise électronique"],"thesis:institution_name":["École de technologie supérieure"]},"updated_at":"2026-11-18T22:08:52Z"}