{"id":{"repo_id":"ets-quebec","oai_identifier":"oai:espace.etsmtl.ca:3194"},"canonical_url":"https://search.ndltd.org/etd/ets-quebec/oai:espace.etsmtl.ca:3194","repository":{"repo_id":"ets-quebec","name":"ETS (Quebec)","base_url":"https://espace.etsmtl.ca/cgi/oai2"},"display":{"title":"Fully printed potentiometric pH sensor","abstract":"Recently, there has been an exceptional growth in research related to the development of flexible sensors for health monitoring and analysis. In particular, pH measurements can be done non-invasively and continuously, making it an excellent parameter for monitoring different stages of wound healing. Here, we report pH sensitivity of a polyaniline/graphite (PANI/G) composite in a fully-printed potentiometric pH sensor and the effect of graphite loading on sensor performance. PANI/G composites in different ratios were aerosol-jet printed on Ag/AgCl with and without a graphite layer as the working electrode in a two-electrode potentiometric sensor on a flexible substrate. The role of the graphite layer on the working electrode has been investigated. PANI/G composites were prepared by a solution processing method using a graphite paste and polyaniline emeraldine salt powder. Samples were characterized by x-ray diffraction, scanning electron microscopy, and Fourier-transform infrared spectroscopy analysis to investigate the relations between the physical and chemical components and the performance of the sensors. The sensors were tested in the pH range from 3 to 10, exhibiting a linear, stable and near-Nernstian sensitivity of 53 mV/pH and a response time of 15 s.","abstract_html":"Recently, there has been an exceptional growth in research related to the development of flexible sensors for health monitoring and analysis. In particular, pH measurements can be done non-invasively and continuously, making it an excellent parameter for monitoring different stages of wound healing. Here, we report pH sensitivity of a polyaniline/graphite (PANI/G) composite in a fully-printed potentiometric pH sensor and the effect of graphite loading on sensor performance. PANI/G composites in different ratios were aerosol-jet printed on Ag/AgCl with and without a graphite layer as the working electrode in a two-electrode potentiometric sensor on a flexible substrate. The role of the graphite layer on the working electrode has been investigated. PANI/G composites were prepared by a solution processing method using a graphite paste and polyaniline emeraldine salt powder. Samples were characterized by x-ray diffraction, scanning electron microscopy, and Fourier-transform infrared spectroscopy analysis to investigate the relations between the physical and chemical components and the performance of the sensors. The sensors were tested in the pH range from 3 to 10, exhibiting a linear, stable and near-Nernstian sensitivity of 53 mV/pH and a response time of 15 s.","abstract_has_math":false,"creators":["Mahinnezhad, Shirin"],"institution":"École de technologie supérieure","degree_name":"Mémoire de maîtrise électronique","degree_level":"masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-01-31","date_published":"2023-01-31","updated_at":"2026-11-18T22:09:45Z","subjects":["capteur de pH, graphite; polyaniline, capteur potentiométrique, impression d'écran, impression par jet d'aérosol, électronique imprimée"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE3194"],"render_values":[{"text":"INSERT-YOUR-LIBRARY-ID-HERE3194","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://espace.etsmtl.ca/id/eprint/3194/1/MAHINNEZHAD_Shirin.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://espace.etsmtl.ca/cgi/oai2?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aespace.etsmtl.ca%3A3194","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Mahinnezhad, Shirin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-01-31"]},{"key":"dc:publisher","label":"Institution","values":["École de technologie supérieure"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Mémoire de maîtrise électronique"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["École de technologie supérieure"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["capteur de pH, graphite; polyaniline, capteur potentiométrique, impression d'écran, impression par jet d'aérosol, électronique imprimée"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE3194","https://espace.etsmtl.ca/id/eprint/3194/1/MAHINNEZHAD_Shirin.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Recently, there has been an exceptional growth in research related to the development of flexible sensors for health monitoring and analysis. In particular, pH measurements can be done non-invasively and continuously, making it an excellent parameter for monitoring different stages of wound healing. Here, we report pH sensitivity of a polyaniline/graphite (PANI/G) composite in a fully-printed potentiometric pH sensor and the effect of graphite loading on sensor performance. PANI/G composites in different ratios were aerosol-jet printed on Ag/AgCl with and without a graphite layer as the working electrode in a two-electrode potentiometric sensor on a flexible substrate. The role of the graphite layer on the working electrode has been investigated. PANI/G composites were prepared by a solution processing method using a graphite paste and polyaniline emeraldine salt powder. Samples were characterized by x-ray diffraction, scanning electron microscopy, and Fourier-transform infrared spectroscopy analysis to investigate the relations between the physical and chemical components and the performance of the sensors. The sensors were tested in the pH range from 3 to 10, exhibiting a linear, stable and near-Nernstian sensitivity of 53 mV/pH and a response time of 15 s."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Fully printed potentiometric pH sensor"]}]}],"canonical_facts":{"dc:creator":["Mahinnezhad, Shirin"],"dc:date":["2023-01-31"],"dc:description":["Recently, there has been an exceptional growth in research related to the development of flexible sensors for health monitoring and analysis. In particular, pH measurements can be done non-invasively and continuously, making it an excellent parameter for monitoring different stages of wound healing. Here, we report pH sensitivity of a polyaniline/graphite (PANI/G) composite in a fully-printed potentiometric pH sensor and the effect of graphite loading on sensor performance. PANI/G composites in different ratios were aerosol-jet printed on Ag/AgCl with and without a graphite layer as the working electrode in a two-electrode potentiometric sensor on a flexible substrate. The role of the graphite layer on the working electrode has been investigated. PANI/G composites were prepared by a solution processing method using a graphite paste and polyaniline emeraldine salt powder. Samples were characterized by x-ray diffraction, scanning electron microscopy, and Fourier-transform infrared spectroscopy analysis to investigate the relations between the physical and chemical components and the performance of the sensors. The sensors were tested in the pH range from 3 to 10, exhibiting a linear, stable and near-Nernstian sensitivity of 53 mV/pH and a response time of 15 s."],"dc:format":["application/pdf"],"dc:identifier":["INSERT-YOUR-LIBRARY-ID-HERE3194","https://espace.etsmtl.ca/id/eprint/3194/1/MAHINNEZHAD_Shirin.pdf"],"dc:language":["en"],"dc:publisher":["École de technologie supérieure"],"dc:subject":["capteur de pH, graphite; polyaniline, capteur potentiométrique, impression d'écran, impression par jet d'aérosol, électronique imprimée"],"dc:title":["Fully printed potentiometric pH sensor"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_level":["masters"],"thesis:degree_name":["Mémoire de maîtrise électronique"],"thesis:institution_name":["École de technologie supérieure"]},"updated_at":"2026-11-18T22:09:45Z"}