{"id":{"repo_id":"ets-quebec","oai_identifier":"oai:espace.etsmtl.ca:3317"},"canonical_url":"https://search.ndltd.org/etd/ets-quebec/oai:espace.etsmtl.ca:3317","repository":{"repo_id":"ets-quebec","name":"ETS (Quebec)","base_url":"https://espace.etsmtl.ca/cgi/oai2"},"display":{"title":"Fault classification in transmission lines utilizing imaging time-series and convolutional neural networks and adaptive relay protection","abstract":"In this research, a model is presented to fault classification in the transmission lines to detect and classify faults while keeping the coordination between the primary and the backup relays by adaptively changing the relay’s parameters accordingly. Furthermore, this research provides a method to select the directional overcurrent primary and backup relays in the transmission lines, as well as the mathematical model for coordinating these relays in a meshed power system. Additionally, a fault classification model based on deep learning as convolutional neural network to determine the fault type within the transmission lines. To comply with convolutional neural network, the voltages and the currents signals were transformed into images using Gramian Angular Field. The objective is to benefit from convolutional neural networks extract the relative temporal features from time-series signals, with the classification process performed using fully connected neural networks. Additionally, to ensure the synchronized operation of the primary and backup relay relays, the coordination between these relays are modelled as an optimization problem with constraints and objective function. Where the objective function is to minimize the total primary relay operating time by using GAMS software. The 9-bus test system is employed to determine optimal relay coordination according to the fault type and evaluate the results in comparison to existing literature.","abstract_html":"In this research, a model is presented to fault classification in the transmission lines to detect and classify faults while keeping the coordination between the primary and the backup relays by adaptively changing the relay’s parameters accordingly. Furthermore, this research provides a method to select the directional overcurrent primary and backup relays in the transmission lines, as well as the mathematical model for coordinating these relays in a meshed power system. Additionally, a fault classification model based on deep learning as convolutional neural network to determine the fault type within the transmission lines. To comply with convolutional neural network, the voltages and the currents signals were transformed into images using Gramian Angular Field. The objective is to benefit from convolutional neural networks extract the relative temporal features from time-series signals, with the classification process performed using fully connected neural networks. Additionally, to ensure the synchronized operation of the primary and backup relay relays, the coordination between these relays are modelled as an optimization problem with constraints and objective function. Where the objective function is to minimize the total primary relay operating time by using GAMS software. The 9-bus test system is employed to determine optimal relay coordination according to the fault type and evaluate the results in comparison to existing literature.","abstract_has_math":false,"creators":["Khabaz, Baraa"],"institution":"École de technologie supérieure","degree_name":"Mémoire de maîtrise électronique","degree_level":"masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-08-29","date_published":"2023-08-29","updated_at":"2026-11-18T22:09:57Z","subjects":["classification des défauts, optimisation, réseau de neurones artificiels, coordination des relais"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE3317"],"render_values":[{"text":"INSERT-YOUR-LIBRARY-ID-HERE3317","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://espace.etsmtl.ca/id/eprint/3317/1/KHABAZ_Baraa.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://espace.etsmtl.ca/cgi/oai2?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aespace.etsmtl.ca%3A3317","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Khabaz, Baraa"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-08-29"]},{"key":"dc:publisher","label":"Institution","values":["École de technologie supérieure"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Mémoire de maîtrise électronique"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["École de technologie supérieure"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["classification des défauts, optimisation, réseau de neurones artificiels, coordination des relais"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE3317","https://espace.etsmtl.ca/id/eprint/3317/1/KHABAZ_Baraa.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this research, a model is presented to fault classification in the transmission lines to detect and classify faults while keeping the coordination between the primary and the backup relays by adaptively changing the relay’s parameters accordingly. Furthermore, this research provides a method to select the directional overcurrent primary and backup relays in the transmission lines, as well as the mathematical model for coordinating these relays in a meshed power system. Additionally, a fault classification model based on deep learning as convolutional neural network to determine the fault type within the transmission lines. To comply with convolutional neural network, the voltages and the currents signals were transformed into images using Gramian Angular Field. The objective is to benefit from convolutional neural networks extract the relative temporal features from time-series signals, with the classification process performed using fully connected neural networks. Additionally, to ensure the synchronized operation of the primary and backup relay relays, the coordination between these relays are modelled as an optimization problem with constraints and objective function. Where the objective function is to minimize the total primary relay operating time by using GAMS software. The 9-bus test system is employed to determine optimal relay coordination according to the fault type and evaluate the results in comparison to existing literature."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Fault classification in transmission lines utilizing imaging time-series and convolutional neural networks and adaptive relay protection"]}]}],"canonical_facts":{"dc:creator":["Khabaz, Baraa"],"dc:date":["2023-08-29"],"dc:description":["In this research, a model is presented to fault classification in the transmission lines to detect and classify faults while keeping the coordination between the primary and the backup relays by adaptively changing the relay’s parameters accordingly. Furthermore, this research provides a method to select the directional overcurrent primary and backup relays in the transmission lines, as well as the mathematical model for coordinating these relays in a meshed power system. Additionally, a fault classification model based on deep learning as convolutional neural network to determine the fault type within the transmission lines. To comply with convolutional neural network, the voltages and the currents signals were transformed into images using Gramian Angular Field. The objective is to benefit from convolutional neural networks extract the relative temporal features from time-series signals, with the classification process performed using fully connected neural networks. Additionally, to ensure the synchronized operation of the primary and backup relay relays, the coordination between these relays are modelled as an optimization problem with constraints and objective function. Where the objective function is to minimize the total primary relay operating time by using GAMS software. The 9-bus test system is employed to determine optimal relay coordination according to the fault type and evaluate the results in comparison to existing literature."],"dc:format":["application/pdf"],"dc:identifier":["INSERT-YOUR-LIBRARY-ID-HERE3317","https://espace.etsmtl.ca/id/eprint/3317/1/KHABAZ_Baraa.pdf"],"dc:language":["en"],"dc:publisher":["École de technologie supérieure"],"dc:subject":["classification des défauts, optimisation, réseau de neurones artificiels, coordination des relais"],"dc:title":["Fault classification in transmission lines utilizing imaging time-series and convolutional neural networks and adaptive relay protection"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_level":["masters"],"thesis:degree_name":["Mémoire de maîtrise électronique"],"thesis:institution_name":["École de technologie supérieure"]},"updated_at":"2026-11-18T22:09:57Z"}