{"id":{"repo_id":"ets-quebec","oai_identifier":"oai:espace.etsmtl.ca:340"},"canonical_url":"https://search.ndltd.org/etd/ets-quebec/oai:espace.etsmtl.ca:340","repository":{"repo_id":"ets-quebec","name":"ETS (Quebec)","base_url":"https://espace.etsmtl.ca/cgi/oai2"},"display":{"title":"Optimization of HVAC control system strategy using two-objective genetic algorithm","abstract":"Intelligent building technology for building operation, called the optimization process, is developed in this thesis. The optimization process, when installed in parallel with a building's central control system, will permit the optimal operation of HVAC systems. Using this proposed optimization process, the supervisory control strategy set points, such as supply air temperature, supply duct static pressure, chilled water supply temperature, supply C02 concentration (or minimum outdoor ventilation), reheat (or zone supply air temperature), and zone air temperature are optimized with respect to energy use and thermal comfort. The multi-objective genetic algorithm that is developed and validated using mathematic and simplified HVAC system problems is used to solve the optimization problem. Detailed VAV components are developed and validated against the monitored data of the investigated existing HVAC system. Adaptive VAV component models using artificial neural networks are also developed for working with most existing building energy management control systems. A ventilation control strategy using supply CO2 concentration set points is developed and integrated into the optimization process. The strategy allows the on-line control of the outdoor air in response to actual building occupancy while ensuring the ventilation requirements of each individual zone. The optimization of the existing HVAC system is done for the three different weather weeks taken from July 2002, February 2003, and May 2003. The simulation results show that by comparing actual and optimal energy use, the on-line implementation of the optimization process could save energy by 19.5%, 50%, and 40%, respectively, while satisfying minimum zone airflow rates and zone thermal comfort. It also shows that the application of a two-objective optimization problem could help control daily energy use or daily building thermal comfort while providing further energy use savings as compared to the one-objective optimization problem.","abstract_html":"Intelligent building technology for building operation, called the optimization process, is developed in this thesis. The optimization process, when installed in parallel with a building&#x27;s central control system, will permit the optimal operation of HVAC systems. Using this proposed optimization process, the supervisory control strategy set points, such as supply air temperature, supply duct static pressure, chilled water supply temperature, supply C02 concentration (or minimum outdoor ventilation), reheat (or zone supply air temperature), and zone air temperature are optimized with respect to energy use and thermal comfort. The multi-objective genetic algorithm that is developed and validated using mathematic and simplified HVAC system problems is used to solve the optimization problem. Detailed VAV components are developed and validated against the monitored data of the investigated existing HVAC system. Adaptive VAV component models using artificial neural networks are also developed for working with most existing building energy management control systems. A ventilation control strategy using supply CO2 concentration set points is developed and integrated into the optimization process. The strategy allows the on-line control of the outdoor air in response to actual building occupancy while ensuring the ventilation requirements of each individual zone. The optimization of the existing HVAC system is done for the three different weather weeks taken from July 2002, February 2003, and May 2003. The simulation results show that by comparing actual and optimal energy use, the on-line implementation of the optimization process could save energy by 19.5%, 50%, and 40%, respectively, while satisfying minimum zone airflow rates and zone thermal comfort. It also shows that the application of a two-objective optimization problem could help control daily energy use or daily building thermal comfort while providing further energy use savings as compared to the one-objective optimization problem.","abstract_has_math":false,"creators":["Nassif, Nabil"],"institution":"École de technologie supérieure","degree_name":"Thèse de doctorat électronique","degree_level":"phd","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-05-04","date_published":"2005-05-04","updated_at":"2026-11-18T22:04:39Z","subjects":["Air, Algorithme, Batiment, Chauffage, Climatisation, Controle, CVCA, Energie, Genetique, HVAC, MOGA, Multicritere, Optimisation, Reel, Systeme, Temps, Ventilation."],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE340"],"render_values":[{"text":"INSERT-YOUR-LIBRARY-ID-HERE340","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://espace.etsmtl.ca/id/eprint/340/1/NASSIF_Nabil.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://espace.etsmtl.ca/cgi/oai2?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aespace.etsmtl.ca%3A340","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Nassif, Nabil"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005-05-04"]},{"key":"dc:publisher","label":"Institution","values":["École de technologie supérieure"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["phd"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Thèse de doctorat électronique"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["École de technologie supérieure"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Air, Algorithme, Batiment, Chauffage, Climatisation, Controle, CVCA, Energie, Genetique, HVAC, MOGA, Multicritere, Optimisation, Reel, Systeme, Temps, Ventilation."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE340","https://espace.etsmtl.ca/id/eprint/340/1/NASSIF_Nabil.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Intelligent building technology for building operation, called the optimization process, is developed in this thesis. The optimization process, when installed in parallel with a building's central control system, will permit the optimal operation of HVAC systems. Using this proposed optimization process, the supervisory control strategy set points, such as supply air temperature, supply duct static pressure, chilled water supply temperature, supply C02 concentration (or minimum outdoor ventilation), reheat (or zone supply air temperature), and zone air temperature are optimized with respect to energy use and thermal comfort. The multi-objective genetic algorithm that is developed and validated using mathematic and simplified HVAC system problems is used to solve the optimization problem. Detailed VAV components are developed and validated against the monitored data of the investigated existing HVAC system. Adaptive VAV component models using artificial neural networks are also developed for working with most existing building energy management control systems. A ventilation control strategy using supply CO2 concentration set points is developed and integrated into the optimization process. The strategy allows the on-line control of the outdoor air in response to actual building occupancy while ensuring the ventilation requirements of each individual zone. The optimization of the existing HVAC system is done for the three different weather weeks taken from July 2002, February 2003, and May 2003. The simulation results show that by comparing actual and optimal energy use, the on-line implementation of the optimization process could save energy by 19.5%, 50%, and 40%, respectively, while satisfying minimum zone airflow rates and zone thermal comfort. It also shows that the application of a two-objective optimization problem could help control daily energy use or daily building thermal comfort while providing further energy use savings as compared to the one-objective optimization problem."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Optimization of HVAC control system strategy using two-objective genetic algorithm"]}]}],"canonical_facts":{"dc:creator":["Nassif, Nabil"],"dc:date":["2005-05-04"],"dc:description":["Intelligent building technology for building operation, called the optimization process, is developed in this thesis. The optimization process, when installed in parallel with a building's central control system, will permit the optimal operation of HVAC systems. Using this proposed optimization process, the supervisory control strategy set points, such as supply air temperature, supply duct static pressure, chilled water supply temperature, supply C02 concentration (or minimum outdoor ventilation), reheat (or zone supply air temperature), and zone air temperature are optimized with respect to energy use and thermal comfort. The multi-objective genetic algorithm that is developed and validated using mathematic and simplified HVAC system problems is used to solve the optimization problem. Detailed VAV components are developed and validated against the monitored data of the investigated existing HVAC system. Adaptive VAV component models using artificial neural networks are also developed for working with most existing building energy management control systems. A ventilation control strategy using supply CO2 concentration set points is developed and integrated into the optimization process. The strategy allows the on-line control of the outdoor air in response to actual building occupancy while ensuring the ventilation requirements of each individual zone. The optimization of the existing HVAC system is done for the three different weather weeks taken from July 2002, February 2003, and May 2003. The simulation results show that by comparing actual and optimal energy use, the on-line implementation of the optimization process could save energy by 19.5%, 50%, and 40%, respectively, while satisfying minimum zone airflow rates and zone thermal comfort. It also shows that the application of a two-objective optimization problem could help control daily energy use or daily building thermal comfort while providing further energy use savings as compared to the one-objective optimization problem."],"dc:format":["application/pdf"],"dc:identifier":["INSERT-YOUR-LIBRARY-ID-HERE340","https://espace.etsmtl.ca/id/eprint/340/1/NASSIF_Nabil.pdf"],"dc:language":["en"],"dc:publisher":["École de technologie supérieure"],"dc:subject":["Air, Algorithme, Batiment, Chauffage, Climatisation, Controle, CVCA, Energie, Genetique, HVAC, MOGA, Multicritere, Optimisation, Reel, Systeme, Temps, Ventilation."],"dc:title":["Optimization of HVAC control system strategy using two-objective genetic algorithm"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_level":["phd"],"thesis:degree_name":["Thèse de doctorat électronique"],"thesis:institution_name":["École de technologie supérieure"]},"updated_at":"2026-11-18T22:04:39Z"}