{"id":{"repo_id":"ets-quebec","oai_identifier":"oai:espace.etsmtl.ca:3471"},"canonical_url":"https://search.ndltd.org/etd/ets-quebec/oai:espace.etsmtl.ca:3471","repository":{"repo_id":"ets-quebec","name":"ETS (Quebec)","base_url":"https://espace.etsmtl.ca/cgi/oai2"},"display":{"title":"Dielectric frequency response analysis applied to stator winding insulation systems","abstract":"This study presents the results of investigations that were performed to verify if the use of low-voltage dielectric frequency response analysis can be successfully applied to detect the deterioration of stator winding insulation systems. For the main investigation, three newly manufactured stator coils with a rated voltage of 13.8 kV were aged using the thermal cycle testing procedures described in IEEE 1310 and an extended and modified version of voltage endurance testing described in IEEE 1553, until dielectric failure. Throughout the accelerated ageing process, several dielectric measurements were performed, and the results trended over time. The results of the dielectric frequency response measurements were then compared with conventional dissipation factor measurements and partial discharge measurements to assess the sensitivity of dielectric frequency response analysis applied to stator insulation. This study also discusses the effects of the nonlinear end-potential grading material on the measured dielectric losses. Additional experiments are summarized to illustrate how this nonlinear material behaves depending on the applied voltage level and frequency. The conclusions of the investigation are also extended, and the principles applied to measurements on complete stator windings, installed in the field.","abstract_html":"This study presents the results of investigations that were performed to verify if the use of low-voltage dielectric frequency response analysis can be successfully applied to detect the deterioration of stator winding insulation systems. For the main investigation, three newly manufactured stator coils with a rated voltage of 13.8 kV were aged using the thermal cycle testing procedures described in IEEE 1310 and an extended and modified version of voltage endurance testing described in IEEE 1553, until dielectric failure. Throughout the accelerated ageing process, several dielectric measurements were performed, and the results trended over time. The results of the dielectric frequency response measurements were then compared with conventional dissipation factor measurements and partial discharge measurements to assess the sensitivity of dielectric frequency response analysis applied to stator insulation. This study also discusses the effects of the nonlinear end-potential grading material on the measured dielectric losses. Additional experiments are summarized to illustrate how this nonlinear material behaves depending on the applied voltage level and frequency. The conclusions of the investigation are also extended, and the principles applied to measurements on complete stator windings, installed in the field.","abstract_has_math":false,"creators":["Lachance-Savard, Mathieu"],"institution":"École de technologie supérieure","degree_name":"Mémoire de maîtrise électronique","degree_level":"masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-04-04","date_published":"2024-04-04","updated_at":"2026-11-18T22:10:21Z","subjects":["spectroscopie fréquentielle, machines tournantes, isolation statorique"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE3471"],"render_values":[{"text":"INSERT-YOUR-LIBRARY-ID-HERE3471","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://espace.etsmtl.ca/id/eprint/3471/1/LACHANCE-SAVARD_Mathieu.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://espace.etsmtl.ca/cgi/oai2?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aespace.etsmtl.ca%3A3471","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Lachance-Savard, Mathieu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-04-04"]},{"key":"dc:publisher","label":"Institution","values":["École de technologie supérieure"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Mémoire de maîtrise électronique"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["École de technologie supérieure"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["spectroscopie fréquentielle, machines tournantes, isolation statorique"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["INSERT-YOUR-LIBRARY-ID-HERE3471","https://espace.etsmtl.ca/id/eprint/3471/1/LACHANCE-SAVARD_Mathieu.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This study presents the results of investigations that were performed to verify if the use of low-voltage dielectric frequency response analysis can be successfully applied to detect the deterioration of stator winding insulation systems. For the main investigation, three newly manufactured stator coils with a rated voltage of 13.8 kV were aged using the thermal cycle testing procedures described in IEEE 1310 and an extended and modified version of voltage endurance testing described in IEEE 1553, until dielectric failure. Throughout the accelerated ageing process, several dielectric measurements were performed, and the results trended over time. The results of the dielectric frequency response measurements were then compared with conventional dissipation factor measurements and partial discharge measurements to assess the sensitivity of dielectric frequency response analysis applied to stator insulation. This study also discusses the effects of the nonlinear end-potential grading material on the measured dielectric losses. Additional experiments are summarized to illustrate how this nonlinear material behaves depending on the applied voltage level and frequency. The conclusions of the investigation are also extended, and the principles applied to measurements on complete stator windings, installed in the field."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Dielectric frequency response analysis applied to stator winding insulation systems"]}]}],"canonical_facts":{"dc:creator":["Lachance-Savard, Mathieu"],"dc:date":["2024-04-04"],"dc:description":["This study presents the results of investigations that were performed to verify if the use of low-voltage dielectric frequency response analysis can be successfully applied to detect the deterioration of stator winding insulation systems. For the main investigation, three newly manufactured stator coils with a rated voltage of 13.8 kV were aged using the thermal cycle testing procedures described in IEEE 1310 and an extended and modified version of voltage endurance testing described in IEEE 1553, until dielectric failure. Throughout the accelerated ageing process, several dielectric measurements were performed, and the results trended over time. The results of the dielectric frequency response measurements were then compared with conventional dissipation factor measurements and partial discharge measurements to assess the sensitivity of dielectric frequency response analysis applied to stator insulation. This study also discusses the effects of the nonlinear end-potential grading material on the measured dielectric losses. Additional experiments are summarized to illustrate how this nonlinear material behaves depending on the applied voltage level and frequency. The conclusions of the investigation are also extended, and the principles applied to measurements on complete stator windings, installed in the field."],"dc:format":["application/pdf"],"dc:identifier":["INSERT-YOUR-LIBRARY-ID-HERE3471","https://espace.etsmtl.ca/id/eprint/3471/1/LACHANCE-SAVARD_Mathieu.pdf"],"dc:language":["en"],"dc:publisher":["École de technologie supérieure"],"dc:subject":["spectroscopie fréquentielle, machines tournantes, isolation statorique"],"dc:title":["Dielectric frequency response analysis applied to stator winding insulation systems"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_level":["masters"],"thesis:degree_name":["Mémoire de maîtrise électronique"],"thesis:institution_name":["École de technologie supérieure"]},"updated_at":"2026-11-18T22:10:21Z"}