{"id":{"repo_id":"etsu","oai_identifier":"oai:dc.etsu.edu:etd-3475"},"canonical_url":"https://search.ndltd.org/etd/etsu/oai:dc.etsu.edu:etd-3475","repository":{"repo_id":"etsu","name":"East Tennessee State University","base_url":"https://dc.etsu.edu/do/oai/"},"display":{"title":"Determination of Hydroquinone in Cosmetic Creams by High Performance Liquid Chromatography.","abstract":"Hydroquinone is a most commonly used whitening agent in cosmetics. A high performance liquid chromatography method was developed and validated for the quantitative determination of hydroquinone in creams. Validation parameters such as linearity, precision, accuracy, and limit of detection and limit of quantitation were determined. HPLC was carried by reverses phase technique on a RP-C18 column with a mobile phase of water and methanol (pH 5.0) 70:30. The linearity in the range of 2.0-40.0 μg/mL presents a correlation coefficient of 0.9998. The LOD and LOQ were 0.16 and 0.53 μg/mL, respectively. The precision of the method was found to be satisfactory with a coefficient of variation below 2.2%. The recovery values were in the range of 92.4 to 99.0%. The method is sensitive, fast, and simple. It has been successfully applied to the determination of hydroquinone in cosmetic creams. The results obtained agreed well with the percentages given by the manufacturers.","abstract_html":"Hydroquinone is a most commonly used whitening agent in cosmetics. A high performance liquid chromatography method was developed and validated for the quantitative determination of hydroquinone in creams. Validation parameters such as linearity, precision, accuracy, and limit of detection and limit of quantitation were determined. HPLC was carried by reverses phase technique on a RP-C18 column with a mobile phase of water and methanol (pH 5.0) 70:30. The linearity in the range of 2.0-40.0 μg/mL presents a correlation coefficient of 0.9998. The LOD and LOQ were 0.16 and 0.53 μg/mL, respectively. The precision of the method was found to be satisfactory with a coefficient of variation below 2.2%. The recovery values were in the range of 92.4 to 99.0%. The method is sensitive, fast, and simple. It has been successfully applied to the determination of hydroquinone in cosmetic creams. The results obtained agreed well with the percentages given by the manufacturers.","abstract_has_math":false,"creators":["Liu, Fuyou"],"institution":null,"degree_name":"MS (Master of Science)","degree_level":"Thesis - restricted","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-08-14T07:00:00Z","date_published":"2007-08-14T07:00:00Z","updated_at":"2026-11-19T07:53:34Z","subjects":["Whitening cream","Hydroquinone","High performance liquid chromatography","Analytical Chemistry","Chemistry","Physical Sciences and Mathematics"],"languages":[],"rights":["Copyright by the authors."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://dc.etsu.edu/etd/2114","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://dc.etsu.edu/etd/2114","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":"https://dc.etsu.edu/context/etd/article/3475/viewcontent/LiuF060207f.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dc.etsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adc.etsu.edu%3Aetd-3475","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Liu, Fuyou"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2007-08-14T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - restricted"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS (Master of Science)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Whitening cream","Hydroquinone","High performance liquid chromatography","Analytical Chemistry","Chemistry","Physical Sciences and Mathematics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright by the authors."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://dc.etsu.edu/context/etd/article/3475/viewcontent/LiuF060207f.pdf","https://dc.etsu.edu/etd/2114"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Hydroquinone is a most commonly used whitening agent in cosmetics. A high performance liquid chromatography method was developed and validated for the quantitative determination of hydroquinone in creams. Validation parameters such as linearity, precision, accuracy, and limit of detection and limit of quantitation were determined. HPLC was carried by reverses phase technique on a RP-C18 column with a mobile phase of water and methanol (pH 5.0) 70:30. The linearity in the range of 2.0-40.0 μg/mL presents a correlation coefficient of 0.9998. The LOD and LOQ were 0.16 and 0.53 μg/mL, respectively. The precision of the method was found to be satisfactory with a coefficient of variation below 2.2%. The recovery values were in the range of 92.4 to 99.0%. The method is sensitive, fast, and simple. It has been successfully applied to the determination of hydroquinone in cosmetic creams. The results obtained agreed well with the percentages given by the manufacturers."]},{"key":"dc:title","label":"Title","values":["Determination of Hydroquinone in Cosmetic Creams by High Performance Liquid Chromatography."]}]}],"canonical_facts":{"dc:creator":["Liu, Fuyou"],"dc:date.issued":["2007-08-14T07:00:00Z"],"dc:description.abstract":["Hydroquinone is a most commonly used whitening agent in cosmetics. A high performance liquid chromatography method was developed and validated for the quantitative determination of hydroquinone in creams. Validation parameters such as linearity, precision, accuracy, and limit of detection and limit of quantitation were determined. HPLC was carried by reverses phase technique on a RP-C18 column with a mobile phase of water and methanol (pH 5.0) 70:30. The linearity in the range of 2.0-40.0 μg/mL presents a correlation coefficient of 0.9998. The LOD and LOQ were 0.16 and 0.53 μg/mL, respectively. The precision of the method was found to be satisfactory with a coefficient of variation below 2.2%. The recovery values were in the range of 92.4 to 99.0%. The method is sensitive, fast, and simple. It has been successfully applied to the determination of hydroquinone in cosmetic creams. The results obtained agreed well with the percentages given by the manufacturers."],"dc:identifier":["https://dc.etsu.edu/context/etd/article/3475/viewcontent/LiuF060207f.pdf","https://dc.etsu.edu/etd/2114"],"dc:rights":["Copyright by the authors."],"dc:subject":["Whitening cream","Hydroquinone","High performance liquid chromatography","Analytical Chemistry","Chemistry","Physical Sciences and Mathematics"],"dc:title":["Determination of Hydroquinone in Cosmetic Creams by High Performance Liquid Chromatography."],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["Thesis - restricted"],"thesis:degree_name":["MS (Master of Science)"]},"updated_at":"2026-11-19T07:53:34Z"}