{"id":{"repo_id":"etsu","oai_identifier":"oai:dc.etsu.edu:etd-4961"},"canonical_url":"https://search.ndltd.org/etd/etsu/oai:dc.etsu.edu:etd-4961","repository":{"repo_id":"etsu","name":"East Tennessee State University","base_url":"https://dc.etsu.edu/do/oai/"},"display":{"title":"Relative Permittivity As A Function of Co-Solvent and Impedance Spectroscopy for Quantifying Anions in Solution","abstract":"This work measured relative permittivity from 15.0 to 55.0 °C of aqueous solutions containing acetone or tetrahydrofuran using a BI 870 dielectric meter. A cubic polynomial fit resulted in coefficients for calculating permittivity as a function of temperature and mole fraction. Literature values for other co-solvent system resulted in similar polynomial coefficients. Using BI 870, permittivity measurements of ionic solutions were not possible because of high conductivity. A simple method using impedance spectroscopy measured these solutions. Impedance decreases with increasing temperature and decreases with increasing ionic strength. Due to the temperature dependence of impedance, all measurements were at 25.0 °C. Anions including bicarbonate, sulfate, acetate, and carbonate were determined using this method. Detection limits were at parts per trillion (ppt) levels. A simple sensor based on smaller stainless steel cylinders and a circuit to determine impedance is currently being developed in combination with an anion exchange column.","abstract_html":"This work measured relative permittivity from 15.0 to 55.0 °C of aqueous solutions containing acetone or tetrahydrofuran using a BI 870 dielectric meter. A cubic polynomial fit resulted in coefficients for calculating permittivity as a function of temperature and mole fraction. Literature values for other co-solvent system resulted in similar polynomial coefficients. Using BI 870, permittivity measurements of ionic solutions were not possible because of high conductivity. A simple method using impedance spectroscopy measured these solutions. Impedance decreases with increasing temperature and decreases with increasing ionic strength. Due to the temperature dependence of impedance, all measurements were at 25.0 °C. Anions including bicarbonate, sulfate, acetate, and carbonate were determined using this method. Detection limits were at parts per trillion (ppt) levels. A simple sensor based on smaller stainless steel cylinders and a circuit to determine impedance is currently being developed in combination with an anion exchange column.","abstract_has_math":false,"creators":["Alseiha, Yahya Sami"],"institution":"East Tennessee State University","degree_name":"MS (Master of Science)","degree_level":"Thesis - unrestricted","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-12-01T08:00:00Z","date_published":"2018-12-01T08:00:00Z","updated_at":"2026-11-19T07:55:46Z","subjects":["Relative Permittivity","Impedance Spectroscopy","Nyquist Plot","Resistivity and Conductivity","Analytical Chemistry"],"languages":["eng"],"rights":["Copyright by the authors."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://dc.etsu.edu/etd/3510","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://dc.etsu.edu/etd/3510","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":"https://dc.etsu.edu/context/etd/article/4961/viewcontent/AlseihaY120418f.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dc.etsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adc.etsu.edu%3Aetd-4961","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Alseiha, Yahya Sami"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2018-11-12T08:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-12-01T08:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["East Tennessee State University"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - unrestricted"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS (Master of Science)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["East Tennessee State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Relative Permittivity","Impedance Spectroscopy","Nyquist Plot","Resistivity and Conductivity","Analytical Chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright by the authors."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://dc.etsu.edu/context/etd/article/4961/viewcontent/AlseihaY120418f.pdf","https://dc.etsu.edu/etd/3510"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This work measured relative permittivity from 15.0 to 55.0 °C of aqueous solutions containing acetone or tetrahydrofuran using a BI 870 dielectric meter. A cubic polynomial fit resulted in coefficients for calculating permittivity as a function of temperature and mole fraction. Literature values for other co-solvent system resulted in similar polynomial coefficients. Using BI 870, permittivity measurements of ionic solutions were not possible because of high conductivity. A simple method using impedance spectroscopy measured these solutions. Impedance decreases with increasing temperature and decreases with increasing ionic strength. Due to the temperature dependence of impedance, all measurements were at 25.0 °C. Anions including bicarbonate, sulfate, acetate, and carbonate were determined using this method. Detection limits were at parts per trillion (ppt) levels. A simple sensor based on smaller stainless steel cylinders and a circuit to determine impedance is currently being developed in combination with an anion exchange column."]},{"key":"dc:title","label":"Title","values":["Relative Permittivity As A Function of Co-Solvent and Impedance Spectroscopy for Quantifying Anions in Solution"]}]}],"canonical_facts":{"dc:creator":["Alseiha, Yahya Sami"],"dc:date.available":["2018-11-12T08:00:00Z"],"dc:date.issued":["2018-12-01T08:00:00Z"],"dc:description.abstract":["This work measured relative permittivity from 15.0 to 55.0 °C of aqueous solutions containing acetone or tetrahydrofuran using a BI 870 dielectric meter. A cubic polynomial fit resulted in coefficients for calculating permittivity as a function of temperature and mole fraction. Literature values for other co-solvent system resulted in similar polynomial coefficients. Using BI 870, permittivity measurements of ionic solutions were not possible because of high conductivity. A simple method using impedance spectroscopy measured these solutions. Impedance decreases with increasing temperature and decreases with increasing ionic strength. Due to the temperature dependence of impedance, all measurements were at 25.0 °C. Anions including bicarbonate, sulfate, acetate, and carbonate were determined using this method. Detection limits were at parts per trillion (ppt) levels. A simple sensor based on smaller stainless steel cylinders and a circuit to determine impedance is currently being developed in combination with an anion exchange column."],"dc:identifier":["https://dc.etsu.edu/context/etd/article/4961/viewcontent/AlseihaY120418f.pdf","https://dc.etsu.edu/etd/3510"],"dc:language":["eng"],"dc:publisher":["East Tennessee State University"],"dc:rights":["Copyright by the authors."],"dc:subject":["Relative Permittivity","Impedance Spectroscopy","Nyquist Plot","Resistivity and Conductivity","Analytical Chemistry"],"dc:title":["Relative Permittivity As A Function of Co-Solvent and Impedance Spectroscopy for Quantifying Anions in Solution"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["Thesis - unrestricted"],"thesis:degree_name":["MS (Master of Science)"],"thesis:institution_name":["East Tennessee State University"]},"updated_at":"2026-11-19T07:55:46Z"}