{"id":{"repo_id":"etsu","oai_identifier":"oai:dc.etsu.edu:etd-5035"},"canonical_url":"https://search.ndltd.org/etd/etsu/oai:dc.etsu.edu:etd-5035","repository":{"repo_id":"etsu","name":"East Tennessee State University","base_url":"https://dc.etsu.edu/do/oai/"},"display":{"title":"A Comparison of Standard Denoising Methods for Peptide Identification","abstract":"Peptide identification using tandem mass spectrometry depends on matching the observed spectrum with the theoretical spectrum. The raw data from tandem mass spectrometry, however, is often not optimal because it may contain noise or measurement errors. Denoising this data can improve alignment between observed and theoretical spectra and reduce the number of peaks. The method used by Lewis et. al (2018) uses a combined constant and moving threshold to denoise spectra. We compare the effects of using the standard preprocessing methods baseline removal, wavelet smoothing, and binning on spectra with Lewis et. al’s threshold method. We consider individual methods and combinations, using measures of distance from Lewis et. al's scoring function for comparison. Our findings showed that no single method provided better results than Lewis et. al's, but combining techniques with that of Lewis et. al's reduced the distance measurements and size of the data set for many peptides.","abstract_html":"Peptide identification using tandem mass spectrometry depends on matching the observed spectrum with the theoretical spectrum. The raw data from tandem mass spectrometry, however, is often not optimal because it may contain noise or measurement errors. Denoising this data can improve alignment between observed and theoretical spectra and reduce the number of peaks. The method used by Lewis et. al (2018) uses a combined constant and moving threshold to denoise spectra. We compare the effects of using the standard preprocessing methods baseline removal, wavelet smoothing, and binning on spectra with Lewis et. al’s threshold method. We consider individual methods and combinations, using measures of distance from Lewis et. al&#x27;s scoring function for comparison. Our findings showed that no single method provided better results than Lewis et. al&#x27;s, but combining techniques with that of Lewis et. al&#x27;s reduced the distance measurements and size of the data set for many peptides.","abstract_has_math":false,"creators":["Carpenter, Skylar"],"institution":"East Tennessee State University","degree_name":"MS (Master of Science)","degree_level":"Thesis - unrestricted","degree_discipline":"Mathematical Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-05-01T07:00:00Z","date_published":"2019-05-01T07:00:00Z","updated_at":"2026-11-19T07:55:54Z","subjects":["Peptide identification","denoising","tandem mass spectrometry","baseline","wavelet","binning","Applied Statistics"],"languages":["eng"],"rights":["Copyright by the authors."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://dc.etsu.edu/etd/3579","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://dc.etsu.edu/etd/3579","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":"https://dc.etsu.edu/context/etd/article/5035/viewcontent/CarpenterS041819f.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dc.etsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adc.etsu.edu%3Aetd-5035","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Carpenter, Skylar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2019-04-01T07:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["East Tennessee State University"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mathematical Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - unrestricted"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS (Master of Science)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["East Tennessee State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Peptide identification","denoising","tandem mass spectrometry","baseline","wavelet","binning","Applied Statistics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright by the authors."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://dc.etsu.edu/context/etd/article/5035/viewcontent/CarpenterS041819f.pdf","https://dc.etsu.edu/etd/3579"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Peptide identification using tandem mass spectrometry depends on matching the observed spectrum with the theoretical spectrum. The raw data from tandem mass spectrometry, however, is often not optimal because it may contain noise or measurement errors. Denoising this data can improve alignment between observed and theoretical spectra and reduce the number of peaks. The method used by Lewis et. al (2018) uses a combined constant and moving threshold to denoise spectra. We compare the effects of using the standard preprocessing methods baseline removal, wavelet smoothing, and binning on spectra with Lewis et. al’s threshold method. We consider individual methods and combinations, using measures of distance from Lewis et. al's scoring function for comparison. Our findings showed that no single method provided better results than Lewis et. al's, but combining techniques with that of Lewis et. al's reduced the distance measurements and size of the data set for many peptides."]},{"key":"dc:title","label":"Title","values":["A Comparison of Standard Denoising Methods for Peptide Identification"]}]}],"canonical_facts":{"dc:creator":["Carpenter, Skylar"],"dc:date.available":["2019-04-01T07:00:00Z"],"dc:date.issued":["2019-05-01T07:00:00Z"],"dc:description.abstract":["Peptide identification using tandem mass spectrometry depends on matching the observed spectrum with the theoretical spectrum. The raw data from tandem mass spectrometry, however, is often not optimal because it may contain noise or measurement errors. Denoising this data can improve alignment between observed and theoretical spectra and reduce the number of peaks. The method used by Lewis et. al (2018) uses a combined constant and moving threshold to denoise spectra. We compare the effects of using the standard preprocessing methods baseline removal, wavelet smoothing, and binning on spectra with Lewis et. al’s threshold method. We consider individual methods and combinations, using measures of distance from Lewis et. al's scoring function for comparison. Our findings showed that no single method provided better results than Lewis et. al's, but combining techniques with that of Lewis et. al's reduced the distance measurements and size of the data set for many peptides."],"dc:identifier":["https://dc.etsu.edu/context/etd/article/5035/viewcontent/CarpenterS041819f.pdf","https://dc.etsu.edu/etd/3579"],"dc:language":["eng"],"dc:publisher":["East Tennessee State University"],"dc:rights":["Copyright by the authors."],"dc:subject":["Peptide identification","denoising","tandem mass spectrometry","baseline","wavelet","binning","Applied Statistics"],"dc:title":["A Comparison of Standard Denoising Methods for Peptide Identification"],"thesis:degree_discipline":["Mathematical Sciences"],"thesis:degree_level":["Thesis - unrestricted"],"thesis:degree_name":["MS (Master of Science)"],"thesis:institution_name":["East Tennessee State University"]},"updated_at":"2026-11-19T07:55:54Z"}