{"id":{"repo_id":"etsu","oai_identifier":"oai:dc.etsu.edu:etd-5132"},"canonical_url":"https://search.ndltd.org/etd/etsu/oai:dc.etsu.edu:etd-5132","repository":{"repo_id":"etsu","name":"East Tennessee State University","base_url":"https://dc.etsu.edu/do/oai/"},"display":{"title":"Automatic Exposure Control During Computed Tomography Scans of the Head: Effects on Dose and Image Quality","abstract":"Automatic exposure control (AEC) is effective at reducing potentially harmful radiation doses without sacrificing image quality for many types of computed tomography (CT) scans. However, there is a need for more information regarding the use of AEC for CT head scans. This study was conducted at Johnson County Community Hospital in Mountain City, TN. Preexisting adult CT head scans (n)60 were randomly selected to form 2 stratified samples, (n)30 each. One sample used a standard protocol, and the other used a protocol with a mA-modulated AEC system, Siemens CARE Dose 4D. Causal-comparative analyses were conducted, and it was determined that AEC was effective at maintaining subjective image quality while reducing radiation doses an average of 38% for adult CT head scans. It was concluded that using AEC was an effective tool to optimize radiation doses for adult CT head scans in one particular setting, but more research on this topic is needed.","abstract_html":"Automatic exposure control (AEC) is effective at reducing potentially harmful radiation doses without sacrificing image quality for many types of computed tomography (CT) scans. However, there is a need for more information regarding the use of AEC for CT head scans. This study was conducted at Johnson County Community Hospital in Mountain City, TN. Preexisting adult CT head scans (n)60 were randomly selected to form 2 stratified samples, (n)30 each. One sample used a standard protocol, and the other used a protocol with a mA-modulated AEC system, Siemens CARE Dose 4D. Causal-comparative analyses were conducted, and it was determined that AEC was effective at maintaining subjective image quality while reducing radiation doses an average of 38% for adult CT head scans. It was concluded that using AEC was an effective tool to optimize radiation doses for adult CT head scans in one particular setting, but more research on this topic is needed.","abstract_has_math":false,"creators":["Osborne, Stephen D"],"institution":"East Tennessee State University","degree_name":"MSAH (Master of Science in Allied Health)","degree_level":"Thesis - unrestricted","degree_discipline":"Allied Health","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-12-01T08:00:00Z","date_published":"2019-12-01T08:00:00Z","updated_at":"2026-11-19T07:56:04Z","subjects":["Computed Tomography","CT Head","Automatic Exposure Control","Dose Reduction","Dose Optimization","mA Modulation","Medicine and Health Sciences","Radiology","Science and Technology Studies"],"languages":["eng"],"rights":["Copyright by the authors."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://dc.etsu.edu/etd/3658","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://dc.etsu.edu/etd/3658","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":"https://dc.etsu.edu/context/etd/article/5132/viewcontent/OsborneS112619f.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dc.etsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adc.etsu.edu%3Aetd-5132","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Osborne, Stephen D"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2019-11-08T08:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-12-01T08:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["East Tennessee State University"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Allied Health"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - unrestricted"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MSAH (Master of Science in Allied Health)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["East Tennessee State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Computed Tomography","CT Head","Automatic Exposure Control","Dose Reduction","Dose Optimization","mA Modulation","Medicine and Health Sciences","Radiology","Science and Technology Studies"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright by the authors."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://dc.etsu.edu/context/etd/article/5132/viewcontent/OsborneS112619f.pdf","https://dc.etsu.edu/etd/3658"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Automatic exposure control (AEC) is effective at reducing potentially harmful radiation doses without sacrificing image quality for many types of computed tomography (CT) scans. However, there is a need for more information regarding the use of AEC for CT head scans. This study was conducted at Johnson County Community Hospital in Mountain City, TN. Preexisting adult CT head scans (n)60 were randomly selected to form 2 stratified samples, (n)30 each. One sample used a standard protocol, and the other used a protocol with a mA-modulated AEC system, Siemens CARE Dose 4D. Causal-comparative analyses were conducted, and it was determined that AEC was effective at maintaining subjective image quality while reducing radiation doses an average of 38% for adult CT head scans. It was concluded that using AEC was an effective tool to optimize radiation doses for adult CT head scans in one particular setting, but more research on this topic is needed."]},{"key":"dc:title","label":"Title","values":["Automatic Exposure Control During Computed Tomography Scans of the Head: Effects on Dose and Image Quality"]}]}],"canonical_facts":{"dc:creator":["Osborne, Stephen D"],"dc:date.available":["2019-11-08T08:00:00Z"],"dc:date.issued":["2019-12-01T08:00:00Z"],"dc:description.abstract":["Automatic exposure control (AEC) is effective at reducing potentially harmful radiation doses without sacrificing image quality for many types of computed tomography (CT) scans. However, there is a need for more information regarding the use of AEC for CT head scans. This study was conducted at Johnson County Community Hospital in Mountain City, TN. Preexisting adult CT head scans (n)60 were randomly selected to form 2 stratified samples, (n)30 each. One sample used a standard protocol, and the other used a protocol with a mA-modulated AEC system, Siemens CARE Dose 4D. Causal-comparative analyses were conducted, and it was determined that AEC was effective at maintaining subjective image quality while reducing radiation doses an average of 38% for adult CT head scans. It was concluded that using AEC was an effective tool to optimize radiation doses for adult CT head scans in one particular setting, but more research on this topic is needed."],"dc:identifier":["https://dc.etsu.edu/context/etd/article/5132/viewcontent/OsborneS112619f.pdf","https://dc.etsu.edu/etd/3658"],"dc:language":["eng"],"dc:publisher":["East Tennessee State University"],"dc:rights":["Copyright by the authors."],"dc:subject":["Computed Tomography","CT Head","Automatic Exposure Control","Dose Reduction","Dose Optimization","mA Modulation","Medicine and Health Sciences","Radiology","Science and Technology Studies"],"dc:title":["Automatic Exposure Control During Computed Tomography Scans of the Head: Effects on Dose and Image Quality"],"thesis:degree_discipline":["Allied Health"],"thesis:degree_level":["Thesis - unrestricted"],"thesis:degree_name":["MSAH (Master of Science in Allied Health)"],"thesis:institution_name":["East Tennessee State University"]},"updated_at":"2026-11-19T07:56:04Z"}