{"id":{"repo_id":"etsu","oai_identifier":"oai:dc.etsu.edu:etd-5794"},"canonical_url":"https://search.ndltd.org/etd/etsu/oai:dc.etsu.edu:etd-5794","repository":{"repo_id":"etsu","name":"East Tennessee State University","base_url":"https://dc.etsu.edu/do/oai/"},"display":{"title":"A Low Cost, Compact Electrochemical Analyzer based on an Open-Source Microcontroller","abstract":"Compared to other instruments for chemical analyses, electrochemical analyzers are relatively simple, inexpensive, easy to miniaturize and require little-to-no maintenance. However, like all commercially available instruments, commercial electrochemical analyzers like potentiostats primarily operate as black boxes with manufacturers providing little or no information about internal circuitry and programming. This practice can limit a researcher’s ability to develop new techniques or adapt an instrument for applications outside its typical use. In contrast, creators of open-source instruments release all the necessary information for reproduction of the hardware and software – minimizing such barriers to innovation in chemical analyses. Here, we report a low-cost, compact potentiostat based on an open-source Arduino microcontroller capable of performing electrochemical analyses such as cyclic and linear sweep voltammetry with an operating range of ± 208 𝜇A and ± 2.5 V. Performance of the potentiostat is investigated with low-cost pencil graphite electrodes and compared to a commercial potentiostat.","abstract_html":"Compared to other instruments for chemical analyses, electrochemical analyzers are relatively simple, inexpensive, easy to miniaturize and require little-to-no maintenance. However, like all commercially available instruments, commercial electrochemical analyzers like potentiostats primarily operate as black boxes with manufacturers providing little or no information about internal circuitry and programming. This practice can limit a researcher’s ability to develop new techniques or adapt an instrument for applications outside its typical use. In contrast, creators of open-source instruments release all the necessary information for reproduction of the hardware and software – minimizing such barriers to innovation in chemical analyses. Here, we report a low-cost, compact potentiostat based on an open-source Arduino microcontroller capable of performing electrochemical analyses such as cyclic and linear sweep voltammetry with an operating range of ± 208 𝜇A and ± 2.5 V. Performance of the potentiostat is investigated with low-cost pencil graphite electrodes and compared to a commercial potentiostat.","abstract_has_math":false,"creators":["Addo, Michael Kofi Darko"],"institution":"East Tennessee State University","degree_name":"MS (Master of Science)","degree_level":"Thesis - embargo","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-08-01T07:00:00Z","date_published":"2023-08-01T07:00:00Z","updated_at":"2026-11-19T07:56:54Z","subjects":["open-source","potentiostat","microcontroller","pulse-width modulation","pencil graphite electrode","Analytical Chemistry"],"languages":["eng"],"rights":["Copyright by Michael Kofi Darko Addo"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://dc.etsu.edu/etd/4258","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://dc.etsu.edu/etd/4258","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":"https://dc.etsu.edu/context/etd/article/5794/viewcontent/AddoM080123f.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dc.etsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adc.etsu.edu%3Aetd-5794","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Addo, Michael Kofi Darko"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-09-15T07:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2023-08-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["East Tennessee State University"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - embargo"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS (Master of Science)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["East Tennessee State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["open-source","potentiostat","microcontroller","pulse-width modulation","pencil graphite electrode","Analytical Chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright by Michael Kofi Darko Addo"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://dc.etsu.edu/context/etd/article/5794/viewcontent/AddoM080123f.pdf","https://dc.etsu.edu/etd/4258"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Compared to other instruments for chemical analyses, electrochemical analyzers are relatively simple, inexpensive, easy to miniaturize and require little-to-no maintenance. However, like all commercially available instruments, commercial electrochemical analyzers like potentiostats primarily operate as black boxes with manufacturers providing little or no information about internal circuitry and programming. This practice can limit a researcher’s ability to develop new techniques or adapt an instrument for applications outside its typical use. In contrast, creators of open-source instruments release all the necessary information for reproduction of the hardware and software – minimizing such barriers to innovation in chemical analyses. Here, we report a low-cost, compact potentiostat based on an open-source Arduino microcontroller capable of performing electrochemical analyses such as cyclic and linear sweep voltammetry with an operating range of ± 208 𝜇A and ± 2.5 V. Performance of the potentiostat is investigated with low-cost pencil graphite electrodes and compared to a commercial potentiostat."]},{"key":"dc:title","label":"Title","values":["A Low Cost, Compact Electrochemical Analyzer based on an Open-Source Microcontroller"]}]}],"canonical_facts":{"dc:creator":["Addo, Michael Kofi Darko"],"dc:date.available":["2024-09-15T07:00:00Z"],"dc:date.issued":["2023-08-01T07:00:00Z"],"dc:description.abstract":["Compared to other instruments for chemical analyses, electrochemical analyzers are relatively simple, inexpensive, easy to miniaturize and require little-to-no maintenance. However, like all commercially available instruments, commercial electrochemical analyzers like potentiostats primarily operate as black boxes with manufacturers providing little or no information about internal circuitry and programming. This practice can limit a researcher’s ability to develop new techniques or adapt an instrument for applications outside its typical use. In contrast, creators of open-source instruments release all the necessary information for reproduction of the hardware and software – minimizing such barriers to innovation in chemical analyses. Here, we report a low-cost, compact potentiostat based on an open-source Arduino microcontroller capable of performing electrochemical analyses such as cyclic and linear sweep voltammetry with an operating range of ± 208 𝜇A and ± 2.5 V. Performance of the potentiostat is investigated with low-cost pencil graphite electrodes and compared to a commercial potentiostat."],"dc:identifier":["https://dc.etsu.edu/context/etd/article/5794/viewcontent/AddoM080123f.pdf","https://dc.etsu.edu/etd/4258"],"dc:language":["eng"],"dc:publisher":["East Tennessee State University"],"dc:rights":["Copyright by Michael Kofi Darko Addo"],"dc:subject":["open-source","potentiostat","microcontroller","pulse-width modulation","pencil graphite electrode","Analytical Chemistry"],"dc:title":["A Low Cost, Compact Electrochemical Analyzer based on an Open-Source Microcontroller"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["Thesis - embargo"],"thesis:degree_name":["MS (Master of Science)"],"thesis:institution_name":["East Tennessee State University"]},"updated_at":"2026-11-19T07:56:54Z"}