{"id":{"repo_id":"etsu","oai_identifier":"oai:dc.etsu.edu:etd-6089"},"canonical_url":"https://search.ndltd.org/etd/etsu/oai:dc.etsu.edu:etd-6089","repository":{"repo_id":"etsu","name":"East Tennessee State University","base_url":"https://dc.etsu.edu/do/oai/"},"display":{"title":"Development of a Portable Electroencephalogram with Display","abstract":"In this experiment, the goal was to design, build, and test an Electroencephalogram (EEG) circuit that would then be paired with a touchscreen display as a portable unit for use in Schizophrenic research at East Tennessee State University at the Quillen College of Medicine. The requirements for this prototype denoted that the device had to be able to obtain a signal from two electrodes placed on the head of an individual with a third attached to the ankle as a ground, amplify and filter the signal, and display the results on a touchscreen display for recording and analyzing. The circuit design was approached using a basic three stage breakdown structure: Acquire, Amplify, Filter. This experiment outlines various lowpass and bandpass active filters used in conjunction with instrumentation amplifiers for signal acquisition and amplification. The final design is a 5th-order 25Hz Lowpass Filter EEG Circuit with variable Gain and Quality Factor.","abstract_html":"In this experiment, the goal was to design, build, and test an Electroencephalogram (EEG) circuit that would then be paired with a touchscreen display as a portable unit for use in Schizophrenic research at East Tennessee State University at the Quillen College of Medicine. The requirements for this prototype denoted that the device had to be able to obtain a signal from two electrodes placed on the head of an individual with a third attached to the ankle as a ground, amplify and filter the signal, and display the results on a touchscreen display for recording and analyzing. The circuit design was approached using a basic three stage breakdown structure: Acquire, Amplify, Filter. This experiment outlines various lowpass and bandpass active filters used in conjunction with instrumentation amplifiers for signal acquisition and amplification. The final design is a 5th-order 25Hz Lowpass Filter EEG Circuit with variable Gain and Quality Factor.","abstract_has_math":false,"creators":["Davis, Seth D"],"institution":"East Tennessee State University","degree_name":"MS (Master of Science)","degree_level":"Thesis - unrestricted","degree_discipline":"Engineering Technology","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-05-01T07:00:00Z","date_published":"2025-05-01T07:00:00Z","updated_at":"2026-11-19T07:57:14Z","subjects":["electroencephalogram","portable","instrumentation amplifier","universal active filter","low pass filter","auditory click train","Biomedical Devices and Instrumentation","Electrical and Electronics"],"languages":["eng"],"rights":["Copyright by the authors."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://dc.etsu.edu/etd/4540","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://dc.etsu.edu/etd/4540","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":"https://dc.etsu.edu/context/etd/article/6089/viewcontent/DavisS042525f.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dc.etsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adc.etsu.edu%3Aetd-6089","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Davis, Seth D"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-07T07:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["East Tennessee State University"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering Technology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - unrestricted"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS (Master of Science)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["East Tennessee State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["electroencephalogram","portable","instrumentation amplifier","universal active filter","low pass filter","auditory click train","Biomedical Devices and Instrumentation","Electrical and Electronics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright by the authors."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://dc.etsu.edu/context/etd/article/6089/viewcontent/DavisS042525f.pdf","https://dc.etsu.edu/etd/4540"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this experiment, the goal was to design, build, and test an Electroencephalogram (EEG) circuit that would then be paired with a touchscreen display as a portable unit for use in Schizophrenic research at East Tennessee State University at the Quillen College of Medicine. The requirements for this prototype denoted that the device had to be able to obtain a signal from two electrodes placed on the head of an individual with a third attached to the ankle as a ground, amplify and filter the signal, and display the results on a touchscreen display for recording and analyzing. The circuit design was approached using a basic three stage breakdown structure: Acquire, Amplify, Filter. This experiment outlines various lowpass and bandpass active filters used in conjunction with instrumentation amplifiers for signal acquisition and amplification. The final design is a 5th-order 25Hz Lowpass Filter EEG Circuit with variable Gain and Quality Factor."]},{"key":"dc:title","label":"Title","values":["Development of a Portable Electroencephalogram with Display"]}]}],"canonical_facts":{"dc:creator":["Davis, Seth D"],"dc:date.available":["2025-04-07T07:00:00Z"],"dc:date.issued":["2025-05-01T07:00:00Z"],"dc:description.abstract":["In this experiment, the goal was to design, build, and test an Electroencephalogram (EEG) circuit that would then be paired with a touchscreen display as a portable unit for use in Schizophrenic research at East Tennessee State University at the Quillen College of Medicine. The requirements for this prototype denoted that the device had to be able to obtain a signal from two electrodes placed on the head of an individual with a third attached to the ankle as a ground, amplify and filter the signal, and display the results on a touchscreen display for recording and analyzing. The circuit design was approached using a basic three stage breakdown structure: Acquire, Amplify, Filter. This experiment outlines various lowpass and bandpass active filters used in conjunction with instrumentation amplifiers for signal acquisition and amplification. The final design is a 5th-order 25Hz Lowpass Filter EEG Circuit with variable Gain and Quality Factor."],"dc:identifier":["https://dc.etsu.edu/context/etd/article/6089/viewcontent/DavisS042525f.pdf","https://dc.etsu.edu/etd/4540"],"dc:language":["eng"],"dc:publisher":["East Tennessee State University"],"dc:rights":["Copyright by the authors."],"dc:subject":["electroencephalogram","portable","instrumentation amplifier","universal active filter","low pass filter","auditory click train","Biomedical Devices and Instrumentation","Electrical and Electronics"],"dc:title":["Development of a Portable Electroencephalogram with Display"],"thesis:degree_discipline":["Engineering Technology"],"thesis:degree_level":["Thesis - unrestricted"],"thesis:degree_name":["MS (Master of Science)"],"thesis:institution_name":["East Tennessee State University"]},"updated_at":"2026-11-19T07:57:14Z"}