{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general-1215"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general-1215","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"COMPARATIVE ANALYSIS OF 2D AND 3D GAIT METRICS FROM VIDEO USING DEEP LEARNING TECHNIQUES","abstract":"This thesis presents a comparative evaluation of two deep learning-based methods for extracting 2D and 3D gait metrics from monocular video: a 2D-to-3D lifting approach combining AlphaPose for keypoint detection with MotionBERT for temporal 3D reconstruction, and a direct 3D estimation method using MeTRAbs. Videos of two healthy adults walking across a ProtoKinetics Zeno™ Walkway were captured laterally at 4K/60 fps using an iPhone 16. Ground-truth spatiotemporal gait parameters were obtained from the pressure-sensitive mat, enabling quantitative validation via Mean Absolute Error (MAE) and Pearson correlation. MeTRAbs consistently outperformed the lifting pipeline, achieving MAE below 2% for temporal metrics (e.g., 1.58% for step time, 1.09% for gait cycle time) and strong correlations (r > 0.90, p < 0.001). Spatial metrics showed MAE of 15.28% (step length) and 15.84% (stride length), with superior robustness to occlusions. AlphaPose+MotionBERT exhibited higher spatial errors (20.40% and 18.47%, respectively) and weaker correlations, though it remained viable for velocity (9.34% MAE) and low-resource settings. The results highlight direct 3D estimation as the preferred method for clinical precision and biomechanical fidelity, while 2D-to-3D lifting offers a lightweight alternative for scalable, non-intrusive monitoring. Future work should expand to pathological gaits, multi-view fusion, and edge-optimized models to broaden real-world applicability.","abstract_html":"This thesis presents a comparative evaluation of two deep learning-based methods for extracting 2D and 3D gait metrics from monocular video: a 2D-to-3D lifting approach combining AlphaPose for keypoint detection with MotionBERT for temporal 3D reconstruction, and a direct 3D estimation method using MeTRAbs. Videos of two healthy adults walking across a ProtoKinetics Zeno™ Walkway were captured laterally at 4K/60 fps using an iPhone 16. Ground-truth spatiotemporal gait parameters were obtained from the pressure-sensitive mat, enabling quantitative validation via Mean Absolute Error (MAE) and Pearson correlation. MeTRAbs consistently outperformed the lifting pipeline, achieving MAE below 2% for temporal metrics (e.g., 1.58% for step time, 1.09% for gait cycle time) and strong correlations (r &gt; 0.90, p &lt; 0.001). Spatial metrics showed MAE of 15.28% (step length) and 15.84% (stride length), with superior robustness to occlusions. AlphaPose+MotionBERT exhibited higher spatial errors (20.40% and 18.47%, respectively) and weaker correlations, though it remained viable for velocity (9.34% MAE) and low-resource settings. The results highlight direct 3D estimation as the preferred method for clinical precision and biomechanical fidelity, while 2D-to-3D lifting offers a lightweight alternative for scalable, non-intrusive monitoring. Future work should expand to pathological gaits, multi-view fusion, and edge-optimized models to broaden real-world applicability.","abstract_has_math":false,"creators":["Kushwaha, Akhilesh Singh"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Computer and Electrical Engineering and Computer Science","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:49:42Z","subjects":["Gait Analysis","2D","3D pose estimation","deep learning","monocular video","AlphaPose","MotionBERT","MeTRAbs","Spatiotemporal Gait metrics","biomechanics","Clinical Gait Assessment"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general/200","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general/200","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general-1215","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general-1215","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kushwaha, Akhilesh Singh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2025-11-25T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Computer and Electrical Engineering and Computer Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Gait Analysis","2D","3D pose estimation","deep learning","monocular video","AlphaPose","MotionBERT","MeTRAbs","Spatiotemporal Gait metrics","biomechanics","Clinical Gait Assessment"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general/200"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents a comparative evaluation of two deep learning-based methods for extracting 2D and 3D gait metrics from monocular video: a 2D-to-3D lifting approach combining AlphaPose for keypoint detection with MotionBERT for temporal 3D reconstruction, and a direct 3D estimation method using MeTRAbs. Videos of two healthy adults walking across a ProtoKinetics Zeno™ Walkway were captured laterally at 4K/60 fps using an iPhone 16. Ground-truth spatiotemporal gait parameters were obtained from the pressure-sensitive mat, enabling quantitative validation via Mean Absolute Error (MAE) and Pearson correlation. MeTRAbs consistently outperformed the lifting pipeline, achieving MAE below 2% for temporal metrics (e.g., 1.58% for step time, 1.09% for gait cycle time) and strong correlations (r > 0.90, p < 0.001). Spatial metrics showed MAE of 15.28% (step length) and 15.84% (stride length), with superior robustness to occlusions. AlphaPose+MotionBERT exhibited higher spatial errors (20.40% and 18.47%, respectively) and weaker correlations, though it remained viable for velocity (9.34% MAE) and low-resource settings. The results highlight direct 3D estimation as the preferred method for clinical precision and biomechanical fidelity, while 2D-to-3D lifting offers a lightweight alternative for scalable, non-intrusive monitoring. Future work should expand to pathological gaits, multi-view fusion, and edge-optimized models to broaden real-world applicability."]},{"key":"dc:title","label":"Title","values":["COMPARATIVE ANALYSIS OF 2D AND 3D GAIT METRICS FROM VIDEO USING DEEP LEARNING TECHNIQUES"]}]}],"canonical_facts":{"dc:creator":["Kushwaha, Akhilesh Singh"],"dc:date.created":["2025-11-25T08:00:00Z"],"dc:description.abstract":["This thesis presents a comparative evaluation of two deep learning-based methods for extracting 2D and 3D gait metrics from monocular video: a 2D-to-3D lifting approach combining AlphaPose for keypoint detection with MotionBERT for temporal 3D reconstruction, and a direct 3D estimation method using MeTRAbs. Videos of two healthy adults walking across a ProtoKinetics Zeno™ Walkway were captured laterally at 4K/60 fps using an iPhone 16. Ground-truth spatiotemporal gait parameters were obtained from the pressure-sensitive mat, enabling quantitative validation via Mean Absolute Error (MAE) and Pearson correlation. MeTRAbs consistently outperformed the lifting pipeline, achieving MAE below 2% for temporal metrics (e.g., 1.58% for step time, 1.09% for gait cycle time) and strong correlations (r > 0.90, p < 0.001). Spatial metrics showed MAE of 15.28% (step length) and 15.84% (stride length), with superior robustness to occlusions. AlphaPose+MotionBERT exhibited higher spatial errors (20.40% and 18.47%, respectively) and weaker correlations, though it remained viable for velocity (9.34% MAE) and low-resource settings. The results highlight direct 3D estimation as the preferred method for clinical precision and biomechanical fidelity, while 2D-to-3D lifting offers a lightweight alternative for scalable, non-intrusive monitoring. Future work should expand to pathological gaits, multi-view fusion, and edge-optimized models to broaden real-world applicability."],"dc:identifier":["https://digitalcommons.fau.edu/etd_general/200"],"dc:subject":["Gait Analysis","2D","3D pose estimation","deep learning","monocular video","AlphaPose","MotionBERT","MeTRAbs","Spatiotemporal Gait metrics","biomechanics","Clinical Gait Assessment"],"dc:title":["COMPARATIVE ANALYSIS OF 2D AND 3D GAIT METRICS FROM VIDEO USING DEEP LEARNING TECHNIQUES"],"thesis:degree_discipline":["Computer and Electrical Engineering and Computer Science"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-26T13:49:42Z"}