{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general-1368"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general-1368","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"DESIGN AND FPGA DEPLOYMENT OF QUANTIZED CONVOLUTIONAL SPIKING NEURAL NETWORKS FOR ECG ARRHYTHMIA CLASSIFICATION","abstract":"Wearable ECG monitors enable continuous cardiac surveillance, yet most remain limited to basic heart rate metrics or coarse atrial fibrillation detection, relying on cloud-based analysis that introduces latency, connectivity dependence, and battery drain. Deploying advanced multi-class arrhythmia classification directly on-device is constrained by the tight memory, power, and computational budgets of wearable hardware. This dissertation presents a Quantized Convolutional Spiking Neural Network (QCSNN) for real-time ECG arrhythmia detection on edge hardware, developed across three progressive phases. Phase 1 introduces a separately trained two-stage QCSNN architecture — a binary classifier cascaded with a four-class classifier — trained directly via surrogate gradient descent and 8-bit quantization-aware training using Brevitas and snnTorch. Compared to ANN-to-SNN conversion approaches, direct training substantially improves minority-class detection (Fusion sensitivity: 83.23% vs. 27.00%), while quantization reduces memory requirements by 76.2% (from 285.60 kB to 67.97 kB) with only 1–4.3% AUC degradation. Phase 2 demonstrates the first FPGA deployment of the separately trained two-stage QCSNN on a PYNQ-Z2 platform, achieving cascaded accuracy within 0.08% of the GPU baseline at approximately 17× lower power consumption (2.15 W vs. 37.09 W). Phase 3 advances the framework through a jointly trained dual-head architecture and a systematic ablation across eight configurations — two loss functions (Cross-Entropy and Focal Loss) crossed with four RR-interval feature routing strategies. The central finding is that RR-interval features substantially diminish the performance advantage of Focal Loss over Cross-Entropy (from +2.5% to near-zero or negative in Stage 2), suggesting that RR features compensate for class imbalance at the input level. The selected configuration (CE:RR→Both) achieves 99.02% cascaded accuracy. Deployed on the PYNQ-Z2 with a unified single-IP design featuring hardware-resident cascade routing, the system achieves 11.552 ms per-beat latency, 0.33 W accelerator power, and 23.32 mJ energy per inference — a 31.66× power reduction and 4.01× energy reduction versus GPU inference. To the best of our knowledge, this represents the first FPGA deployment of a fully quantized, directly trained SNN for multi-class ECG arrhythmia detection with systematic GPU-FPGA validation.","abstract_html":"Wearable ECG monitors enable continuous cardiac surveillance, yet most remain limited to basic heart rate metrics or coarse atrial fibrillation detection, relying on cloud-based analysis that introduces latency, connectivity dependence, and battery drain. Deploying advanced multi-class arrhythmia classification directly on-device is constrained by the tight memory, power, and computational budgets of wearable hardware. This dissertation presents a Quantized Convolutional Spiking Neural Network (QCSNN) for real-time ECG arrhythmia detection on edge hardware, developed across three progressive phases. Phase 1 introduces a separately trained two-stage QCSNN architecture — a binary classifier cascaded with a four-class classifier — trained directly via surrogate gradient descent and 8-bit quantization-aware training using Brevitas and snnTorch. Compared to ANN-to-SNN conversion approaches, direct training substantially improves minority-class detection (Fusion sensitivity: 83.23% vs. 27.00%), while quantization reduces memory requirements by 76.2% (from 285.60 kB to 67.97 kB) with only 1–4.3% AUC degradation. Phase 2 demonstrates the first FPGA deployment of the separately trained two-stage QCSNN on a PYNQ-Z2 platform, achieving cascaded accuracy within 0.08% of the GPU baseline at approximately 17× lower power consumption (2.15 W vs. 37.09 W). Phase 3 advances the framework through a jointly trained dual-head architecture and a systematic ablation across eight configurations — two loss functions (Cross-Entropy and Focal Loss) crossed with four RR-interval feature routing strategies. The central finding is that RR-interval features substantially diminish the performance advantage of Focal Loss over Cross-Entropy (from +2.5% to near-zero or negative in Stage 2), suggesting that RR features compensate for class imbalance at the input level. The selected configuration (CE:RR→Both) achieves 99.02% cascaded accuracy. Deployed on the PYNQ-Z2 with a unified single-IP design featuring hardware-resident cascade routing, the system achieves 11.552 ms per-beat latency, 0.33 W accelerator power, and 23.32 mJ energy per inference — a 31.66× power reduction and 4.01× energy reduction versus GPU inference. To the best of our knowledge, this represents the first FPGA deployment of a fully quantized, directly trained SNN for multi-class ECG arrhythmia detection with systematic GPU-FPGA validation.","abstract_has_math":false,"creators":["Banjo, Olamilekan"],"institution":null,"degree_name":"Doctor of Philosophy (PhD)","degree_level":"Dissertation","degree_discipline":"Computer and Electrical Engineering and Computer Science","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:49:55Z","subjects":["Quantized Convolutional SNN","QCSNN","SNN","ECG Arrhythmia Classification","ECG","Arrhythmia Detection","Digital Healthcare and Well-being","FPGA Acceleration","Edge Computing","Wearable Health Monitoring","RR Interval Features","Loss Function-RR Features Interaction","Computer Engineering","Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general/395","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general/395","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general-1368","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general-1368","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Banjo, Olamilekan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2026-07-02T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Computer and Electrical Engineering and Computer Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Quantized Convolutional SNN","QCSNN","SNN","ECG Arrhythmia Classification","ECG","Arrhythmia Detection","Digital Healthcare and Well-being","FPGA Acceleration","Edge Computing","Wearable Health Monitoring","RR Interval Features","Loss Function-RR Features Interaction","Computer Engineering","Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general/395"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Wearable ECG monitors enable continuous cardiac surveillance, yet most remain limited to basic heart rate metrics or coarse atrial fibrillation detection, relying on cloud-based analysis that introduces latency, connectivity dependence, and battery drain. Deploying advanced multi-class arrhythmia classification directly on-device is constrained by the tight memory, power, and computational budgets of wearable hardware. This dissertation presents a Quantized Convolutional Spiking Neural Network (QCSNN) for real-time ECG arrhythmia detection on edge hardware, developed across three progressive phases. Phase 1 introduces a separately trained two-stage QCSNN architecture — a binary classifier cascaded with a four-class classifier — trained directly via surrogate gradient descent and 8-bit quantization-aware training using Brevitas and snnTorch. Compared to ANN-to-SNN conversion approaches, direct training substantially improves minority-class detection (Fusion sensitivity: 83.23% vs. 27.00%), while quantization reduces memory requirements by 76.2% (from 285.60 kB to 67.97 kB) with only 1–4.3% AUC degradation. Phase 2 demonstrates the first FPGA deployment of the separately trained two-stage QCSNN on a PYNQ-Z2 platform, achieving cascaded accuracy within 0.08% of the GPU baseline at approximately 17× lower power consumption (2.15 W vs. 37.09 W). Phase 3 advances the framework through a jointly trained dual-head architecture and a systematic ablation across eight configurations — two loss functions (Cross-Entropy and Focal Loss) crossed with four RR-interval feature routing strategies. The central finding is that RR-interval features substantially diminish the performance advantage of Focal Loss over Cross-Entropy (from +2.5% to near-zero or negative in Stage 2), suggesting that RR features compensate for class imbalance at the input level. The selected configuration (CE:RR→Both) achieves 99.02% cascaded accuracy. Deployed on the PYNQ-Z2 with a unified single-IP design featuring hardware-resident cascade routing, the system achieves 11.552 ms per-beat latency, 0.33 W accelerator power, and 23.32 mJ energy per inference — a 31.66× power reduction and 4.01× energy reduction versus GPU inference. To the best of our knowledge, this represents the first FPGA deployment of a fully quantized, directly trained SNN for multi-class ECG arrhythmia detection with systematic GPU-FPGA validation."]},{"key":"dc:title","label":"Title","values":["DESIGN AND FPGA DEPLOYMENT OF QUANTIZED CONVOLUTIONAL SPIKING NEURAL NETWORKS FOR ECG ARRHYTHMIA CLASSIFICATION"]}]}],"canonical_facts":{"dc:creator":["Banjo, Olamilekan"],"dc:date.created":["2026-07-02T07:00:00Z"],"dc:description.abstract":["Wearable ECG monitors enable continuous cardiac surveillance, yet most remain limited to basic heart rate metrics or coarse atrial fibrillation detection, relying on cloud-based analysis that introduces latency, connectivity dependence, and battery drain. Deploying advanced multi-class arrhythmia classification directly on-device is constrained by the tight memory, power, and computational budgets of wearable hardware. This dissertation presents a Quantized Convolutional Spiking Neural Network (QCSNN) for real-time ECG arrhythmia detection on edge hardware, developed across three progressive phases. Phase 1 introduces a separately trained two-stage QCSNN architecture — a binary classifier cascaded with a four-class classifier — trained directly via surrogate gradient descent and 8-bit quantization-aware training using Brevitas and snnTorch. Compared to ANN-to-SNN conversion approaches, direct training substantially improves minority-class detection (Fusion sensitivity: 83.23% vs. 27.00%), while quantization reduces memory requirements by 76.2% (from 285.60 kB to 67.97 kB) with only 1–4.3% AUC degradation. Phase 2 demonstrates the first FPGA deployment of the separately trained two-stage QCSNN on a PYNQ-Z2 platform, achieving cascaded accuracy within 0.08% of the GPU baseline at approximately 17× lower power consumption (2.15 W vs. 37.09 W). Phase 3 advances the framework through a jointly trained dual-head architecture and a systematic ablation across eight configurations — two loss functions (Cross-Entropy and Focal Loss) crossed with four RR-interval feature routing strategies. The central finding is that RR-interval features substantially diminish the performance advantage of Focal Loss over Cross-Entropy (from +2.5% to near-zero or negative in Stage 2), suggesting that RR features compensate for class imbalance at the input level. The selected configuration (CE:RR→Both) achieves 99.02% cascaded accuracy. Deployed on the PYNQ-Z2 with a unified single-IP design featuring hardware-resident cascade routing, the system achieves 11.552 ms per-beat latency, 0.33 W accelerator power, and 23.32 mJ energy per inference — a 31.66× power reduction and 4.01× energy reduction versus GPU inference. To the best of our knowledge, this represents the first FPGA deployment of a fully quantized, directly trained SNN for multi-class ECG arrhythmia detection with systematic GPU-FPGA validation."],"dc:identifier":["https://digitalcommons.fau.edu/etd_general/395"],"dc:subject":["Quantized Convolutional SNN","QCSNN","SNN","ECG Arrhythmia Classification","ECG","Arrhythmia Detection","Digital Healthcare and Well-being","FPGA Acceleration","Edge Computing","Wearable Health Monitoring","RR Interval Features","Loss Function-RR Features Interaction","Computer Engineering","Engineering"],"dc:title":["DESIGN AND FPGA DEPLOYMENT OF QUANTIZED CONVOLUTIONAL SPIKING NEURAL NETWORKS FOR ECG ARRHYTHMIA CLASSIFICATION"],"thesis:degree_discipline":["Computer and Electrical Engineering and Computer Science"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Doctor of Philosophy (PhD)"]},"updated_at":"2026-11-26T13:49:55Z"}