{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general-1783"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general-1783","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Non-Invasive Measurement Methods for Transient Flows in Wind Tunnels","abstract":"A non-invasive transient state measurement method for wind tunnels would be very valuable as an experimental tool. Traditional measurement techniques for transient flows, e.g., hot wire anemometry, require sensors that are placed in the flow. Alternatively, particle image velocimetry (PIV) may be used to measure transient flows non intrusively, but applying PIV requires sensors that are expensive, and it may take months to process the data. The non-invasive measurement techniques considered in this thesis utilize sensors that are imbedded into the wall of a wind tunnel, or the response of a Kevlar walled wind tunnel to obtain the pressure time histories of a transient flow. These measurements are suitable and accurate for analyzing steady state flows but the feasibility of using them on time varying flows has yet to be explored. If this method proves possible, it would be very beneficial even if it is less accurate than current invasive methods because it would give results in real time. This thesis investigates a simple transient flow of the startup vortex of an airfoil caused by a step change in angle of attack. Based on thin airfoil theory, two models of an airfoil were created. It was determined that the response of a Kevlar wall can measure the unsteady lift of an airfoil.","abstract_html":"A non-invasive transient state measurement method for wind tunnels would be very valuable as an experimental tool. Traditional measurement techniques for transient flows, e.g., hot wire anemometry, require sensors that are placed in the flow. Alternatively, particle image velocimetry (PIV) may be used to measure transient flows non intrusively, but applying PIV requires sensors that are expensive, and it may take months to process the data. The non-invasive measurement techniques considered in this thesis utilize sensors that are imbedded into the wall of a wind tunnel, or the response of a Kevlar walled wind tunnel to obtain the pressure time histories of a transient flow. These measurements are suitable and accurate for analyzing steady state flows but the feasibility of using them on time varying flows has yet to be explored. If this method proves possible, it would be very beneficial even if it is less accurate than current invasive methods because it would give results in real time. This thesis investigates a simple transient flow of the startup vortex of an airfoil caused by a step change in angle of attack. Based on thin airfoil theory, two models of an airfoil were created. It was determined that the response of a Kevlar wall can measure the unsteady lift of an airfoil.","abstract_has_math":false,"creators":["Marcheggiani, Joseph P"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:56:34Z","subjects":["Wind tunnels","Transient flow (Aerodynamics)","Measurement","Sensors"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general/782","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general/782","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general-1783","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general-1783","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Marcheggiani, Joseph P"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2021-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Wind tunnels","Transient flow (Aerodynamics)","Measurement","Sensors"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general/782"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A non-invasive transient state measurement method for wind tunnels would be very valuable as an experimental tool. Traditional measurement techniques for transient flows, e.g., hot wire anemometry, require sensors that are placed in the flow. Alternatively, particle image velocimetry (PIV) may be used to measure transient flows non intrusively, but applying PIV requires sensors that are expensive, and it may take months to process the data. The non-invasive measurement techniques considered in this thesis utilize sensors that are imbedded into the wall of a wind tunnel, or the response of a Kevlar walled wind tunnel to obtain the pressure time histories of a transient flow. These measurements are suitable and accurate for analyzing steady state flows but the feasibility of using them on time varying flows has yet to be explored. If this method proves possible, it would be very beneficial even if it is less accurate than current invasive methods because it would give results in real time. This thesis investigates a simple transient flow of the startup vortex of an airfoil caused by a step change in angle of attack. Based on thin airfoil theory, two models of an airfoil were created. It was determined that the response of a Kevlar wall can measure the unsteady lift of an airfoil."]},{"key":"dc:description.note","label":"Dc Description Note","values":["Includes bibliography.|Thesis (MS)--Florida Atlantic University, 2021.|FAU Electronic Theses and Dissertations Collection|Includes bibliography."]},{"key":"dc:title","label":"Title","values":["Non-Invasive Measurement Methods for Transient Flows in Wind Tunnels"]}]}],"canonical_facts":{"dc:creator":["Marcheggiani, Joseph P"],"dc:date.created":["2021-01-01T08:00:00Z"],"dc:description.abstract":["A non-invasive transient state measurement method for wind tunnels would be very valuable as an experimental tool. Traditional measurement techniques for transient flows, e.g., hot wire anemometry, require sensors that are placed in the flow. Alternatively, particle image velocimetry (PIV) may be used to measure transient flows non intrusively, but applying PIV requires sensors that are expensive, and it may take months to process the data. The non-invasive measurement techniques considered in this thesis utilize sensors that are imbedded into the wall of a wind tunnel, or the response of a Kevlar walled wind tunnel to obtain the pressure time histories of a transient flow. These measurements are suitable and accurate for analyzing steady state flows but the feasibility of using them on time varying flows has yet to be explored. If this method proves possible, it would be very beneficial even if it is less accurate than current invasive methods because it would give results in real time. This thesis investigates a simple transient flow of the startup vortex of an airfoil caused by a step change in angle of attack. Based on thin airfoil theory, two models of an airfoil were created. It was determined that the response of a Kevlar wall can measure the unsteady lift of an airfoil."],"dc:description.note":["Includes bibliography.|Thesis (MS)--Florida Atlantic University, 2021.|FAU Electronic Theses and Dissertations Collection|Includes bibliography."],"dc:identifier":["https://digitalcommons.fau.edu/etd_general/782"],"dc:subject":["Wind tunnels","Transient flow (Aerodynamics)","Measurement","Sensors"],"dc:title":["Non-Invasive Measurement Methods for Transient Flows in Wind Tunnels"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:56:34Z"}