{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_1-1008"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_1-1008","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Measurement of Electron Temperature and Density in a Reflex Discharge","abstract":"An experimental investigation of a reflex discharge in Argon is carried out. Definition is made of a region of acceptable operating parameters consistent with continuous, stable operation of the plasma. Electron temperature is measured through the use of spectroscopy, electrostatic wave propagation, and Langmuir Probes. An electron temperature in the 1 eV to 5 eV range is indicated. Electron density is measured through the observation of the upperhybrid frequency. This observation yields an electron density in the region from .27 x 10^8/cm^3 to 2.38 x 10^8/cm^3. The microwave apparatus used in the density measurement is described in detail.","abstract_html":"An experimental investigation of a reflex discharge in Argon is carried out. Definition is made of a region of acceptable operating parameters consistent with continuous, stable operation of the plasma. Electron temperature is measured through the use of spectroscopy, electrostatic wave propagation, and Langmuir Probes. An electron temperature in the 1 eV to 5 eV range is indicated. Electron density is measured through the observation of the upperhybrid frequency. This observation yields an electron density in the region from .27 x 10^8/cm^3 to 2.38 x 10^8/cm^3. The microwave apparatus used in the density measurement is described in detail.","abstract_has_math":false,"creators":["Scalise, Stanley J"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:50:00Z","subjects":["Plasma (Ionized gases)","Low temperature plasmas","Plasma density","Microwave measurements","Plasma diagnostics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_1/9","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_1/9","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_1-1008","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_1-1008","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Scalise, Stanley J"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1967-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Plasma (Ionized gases)","Low temperature plasmas","Plasma density","Microwave measurements","Plasma diagnostics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_1/9"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An experimental investigation of a reflex discharge in Argon is carried out. Definition is made of a region of acceptable operating parameters consistent with continuous, stable operation of the plasma. Electron temperature is measured through the use of spectroscopy, electrostatic wave propagation, and Langmuir Probes. An electron temperature in the 1 eV to 5 eV range is indicated. Electron density is measured through the observation of the upperhybrid frequency. This observation yields an electron density in the region from .27 x 10^8/cm^3 to 2.38 x 10^8/cm^3. The microwave apparatus used in the density measurement is described in detail."]},{"key":"dc:description.note","label":"Dc Description Note","values":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 1967.|FAU Electronic Theses and Dissertations Collection|Charles E. Schmidt College of Science|Includes bibliography."]},{"key":"dc:title","label":"Title","values":["Measurement of Electron Temperature and Density in a Reflex Discharge"]}]}],"canonical_facts":{"dc:creator":["Scalise, Stanley J"],"dc:date.created":["1967-01-01T08:00:00Z"],"dc:description.abstract":["An experimental investigation of a reflex discharge in Argon is carried out. Definition is made of a region of acceptable operating parameters consistent with continuous, stable operation of the plasma. Electron temperature is measured through the use of spectroscopy, electrostatic wave propagation, and Langmuir Probes. An electron temperature in the 1 eV to 5 eV range is indicated. Electron density is measured through the observation of the upperhybrid frequency. This observation yields an electron density in the region from .27 x 10^8/cm^3 to 2.38 x 10^8/cm^3. The microwave apparatus used in the density measurement is described in detail."],"dc:description.note":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 1967.|FAU Electronic Theses and Dissertations Collection|Charles E. Schmidt College of Science|Includes bibliography."],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_1/9"],"dc:subject":["Plasma (Ionized gases)","Low temperature plasmas","Plasma density","Microwave measurements","Plasma diagnostics"],"dc:title":["Measurement of Electron Temperature and Density in a Reflex Discharge"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:50:00Z"}