{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_2-1496"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_2-1496","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"SPECIFIC ACOUSTIC IMPEDANCE OF FERROMANGANESE NODULES AT EIGHT KILOHERTZ","abstract":"Ferromanganese nodules are small, irregular lumps of precipitated metal oxides composed primarily of manganese, iron, copper, cobalt, and nickel which accrete in deep ocean environments. The nodules have mining value and commercial recovery is expected in the near future. As present techniques for the detection and evaluation of ferromanganese nodule deposits are cumbersome and time consuming, an investigation of the specific acoustic impedance of the nodules is conducted in an effort to determine the feasibility of surveying ferromanganese nodule deposits via side-scan sonar techniques. An acoustic transmission line (impedance tube) is utilized to investigate the specific acoustic impedance of the ferromanganese nodule samples. The accuracy of the experimental technique is evaluated using a steel reference cylinder. Results of the tests (on the ferromanganese samples) indicate that the specific acoustic impedance of a typical ferromanganese nodule sample is 2.07 +- .15 x 106 Rayls. Suggestions for future investigations are also presented.","abstract_html":"Ferromanganese nodules are small, irregular lumps of precipitated metal oxides composed primarily of manganese, iron, copper, cobalt, and nickel which accrete in deep ocean environments. The nodules have mining value and commercial recovery is expected in the near future. As present techniques for the detection and evaluation of ferromanganese nodule deposits are cumbersome and time consuming, an investigation of the specific acoustic impedance of the nodules is conducted in an effort to determine the feasibility of surveying ferromanganese nodule deposits via side-scan sonar techniques. An acoustic transmission line (impedance tube) is utilized to investigate the specific acoustic impedance of the ferromanganese nodule samples. The accuracy of the experimental technique is evaluated using a steel reference cylinder. Results of the tests (on the ferromanganese samples) indicate that the specific acoustic impedance of a typical ferromanganese nodule sample is 2.07 +- .15 x 106 Rayls. Suggestions for future investigations are also presented.","abstract_has_math":false,"creators":["GARDNER, DAVID LEE"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:50:23Z","subjects":["Ferromanganese--Analysis","Acoustic impedance--Instruments"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_2/497","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_2/497","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_2-1496","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_2-1496","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["GARDNER, DAVID LEE"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1976-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ferromanganese--Analysis","Acoustic impedance--Instruments"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_2/497"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Ferromanganese nodules are small, irregular lumps of precipitated metal oxides composed primarily of manganese, iron, copper, cobalt, and nickel which accrete in deep ocean environments. The nodules have mining value and commercial recovery is expected in the near future. As present techniques for the detection and evaluation of ferromanganese nodule deposits are cumbersome and time consuming, an investigation of the specific acoustic impedance of the nodules is conducted in an effort to determine the feasibility of surveying ferromanganese nodule deposits via side-scan sonar techniques. An acoustic transmission line (impedance tube) is utilized to investigate the specific acoustic impedance of the ferromanganese nodule samples. The accuracy of the experimental technique is evaluated using a steel reference cylinder. Results of the tests (on the ferromanganese samples) indicate that the specific acoustic impedance of a typical ferromanganese nodule sample is 2.07 +- .15 x 106 Rayls. Suggestions for future investigations are also presented."]},{"key":"dc:description.note","label":"Dc Description Note","values":["College of Engineering and Computer Science|Thesis (M.S.E.)--Florida Atlantic University, 1976.|FAU Electronic Theses and Dissertations Collection|College of Engineering and Computer Science"]},{"key":"dc:title","label":"Title","values":["SPECIFIC ACOUSTIC IMPEDANCE OF FERROMANGANESE NODULES AT EIGHT KILOHERTZ"]}]}],"canonical_facts":{"dc:creator":["GARDNER, DAVID LEE"],"dc:date.created":["1976-01-01T08:00:00Z"],"dc:description.abstract":["Ferromanganese nodules are small, irregular lumps of precipitated metal oxides composed primarily of manganese, iron, copper, cobalt, and nickel which accrete in deep ocean environments. The nodules have mining value and commercial recovery is expected in the near future. As present techniques for the detection and evaluation of ferromanganese nodule deposits are cumbersome and time consuming, an investigation of the specific acoustic impedance of the nodules is conducted in an effort to determine the feasibility of surveying ferromanganese nodule deposits via side-scan sonar techniques. An acoustic transmission line (impedance tube) is utilized to investigate the specific acoustic impedance of the ferromanganese nodule samples. The accuracy of the experimental technique is evaluated using a steel reference cylinder. Results of the tests (on the ferromanganese samples) indicate that the specific acoustic impedance of a typical ferromanganese nodule sample is 2.07 +- .15 x 106 Rayls. Suggestions for future investigations are also presented."],"dc:description.note":["College of Engineering and Computer Science|Thesis (M.S.E.)--Florida Atlantic University, 1976.|FAU Electronic Theses and Dissertations Collection|College of Engineering and Computer Science"],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_2/497"],"dc:subject":["Ferromanganese--Analysis","Acoustic impedance--Instruments"],"dc:title":["SPECIFIC ACOUSTIC IMPEDANCE OF FERROMANGANESE NODULES AT EIGHT KILOHERTZ"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:50:23Z"}