{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_3-1355"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_3-1355","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"CORROSION OF STEEL REINFORCEMENT IN CONCRETE: THRESHOLD CHLORIDE ION CONCENTRATION FOR CORROSION IN TYPE I PORTLAND CEMENT CONCRETE","abstract":"Initiation of corrosion of reinforcing steel in concrete is often caused by chlorides. Using a pressurized method for the purpose of accelerating penetration of sea water into concrete, the threshold chloride ion concentration for corrosion of reinforcing steel in Type I portland cement concrete has been studied in detail. The variables that have been investigated include water-cement ratio and steel surface preparation. When corrosion was detected by electrochemical potential measurement, the test was terminated; and chloride ion concentration was evaluated. No correlation between threshold concentration and water-cement ratio was found. With regard to surface condition, the pre-rusted steel specimen showed a tendency to corrode at a lesser chloride ion concentration than for the other preparation techniques, which were sand blasting and pretreatment in a saturated calcium hydroxide solution. The results are presented and discussed within a perspective of established concrete and corrosion technologies.","abstract_html":"Initiation of corrosion of reinforcing steel in concrete is often caused by chlorides. Using a pressurized method for the purpose of accelerating penetration of sea water into concrete, the threshold chloride ion concentration for corrosion of reinforcing steel in Type I portland cement concrete has been studied in detail. The variables that have been investigated include water-cement ratio and steel surface preparation. When corrosion was detected by electrochemical potential measurement, the test was terminated; and chloride ion concentration was evaluated. No correlation between threshold concentration and water-cement ratio was found. With regard to surface condition, the pre-rusted steel specimen showed a tendency to corrode at a lesser chloride ion concentration than for the other preparation techniques, which were sand blasting and pretreatment in a saturated calcium hydroxide solution. The results are presented and discussed within a perspective of established concrete and corrosion technologies.","abstract_has_math":false,"creators":["FUNAHASHI, MIKI."],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:50:53Z","subjects":["Steel--Corrosion","Reinforced concrete"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_3/356","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_3/356","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_3-1355","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_3-1355","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["FUNAHASHI, MIKI."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1985-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Steel--Corrosion","Reinforced concrete"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_3/356"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Initiation of corrosion of reinforcing steel in concrete is often caused by chlorides. Using a pressurized method for the purpose of accelerating penetration of sea water into concrete, the threshold chloride ion concentration for corrosion of reinforcing steel in Type I portland cement concrete has been studied in detail. The variables that have been investigated include water-cement ratio and steel surface preparation. When corrosion was detected by electrochemical potential measurement, the test was terminated; and chloride ion concentration was evaluated. No correlation between threshold concentration and water-cement ratio was found. With regard to surface condition, the pre-rusted steel specimen showed a tendency to corrode at a lesser chloride ion concentration than for the other preparation techniques, which were sand blasting and pretreatment in a saturated calcium hydroxide solution. The results are presented and discussed within a perspective of established concrete and corrosion technologies."]},{"key":"dc:description.note","label":"Dc Description Note","values":["College of Engineering and Computer Science|Thesis (M.S.)--Florida Atlantic University, 1985.|FAU Electronic Theses and Dissertations Collection|College of Engineering and Computer Science"]},{"key":"dc:title","label":"Title","values":["CORROSION OF STEEL REINFORCEMENT IN CONCRETE: THRESHOLD CHLORIDE ION CONCENTRATION FOR CORROSION IN TYPE I PORTLAND CEMENT CONCRETE"]}]}],"canonical_facts":{"dc:creator":["FUNAHASHI, MIKI."],"dc:date.created":["1985-01-01T08:00:00Z"],"dc:description.abstract":["Initiation of corrosion of reinforcing steel in concrete is often caused by chlorides. Using a pressurized method for the purpose of accelerating penetration of sea water into concrete, the threshold chloride ion concentration for corrosion of reinforcing steel in Type I portland cement concrete has been studied in detail. The variables that have been investigated include water-cement ratio and steel surface preparation. When corrosion was detected by electrochemical potential measurement, the test was terminated; and chloride ion concentration was evaluated. No correlation between threshold concentration and water-cement ratio was found. With regard to surface condition, the pre-rusted steel specimen showed a tendency to corrode at a lesser chloride ion concentration than for the other preparation techniques, which were sand blasting and pretreatment in a saturated calcium hydroxide solution. The results are presented and discussed within a perspective of established concrete and corrosion technologies."],"dc:description.note":["College of Engineering and Computer Science|Thesis (M.S.)--Florida Atlantic University, 1985.|FAU Electronic Theses and Dissertations Collection|College of Engineering and Computer Science"],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_3/356"],"dc:subject":["Steel--Corrosion","Reinforced concrete"],"dc:title":["CORROSION OF STEEL REINFORCEMENT IN CONCRETE: THRESHOLD CHLORIDE ION CONCENTRATION FOR CORROSION IN TYPE I PORTLAND CEMENT CONCRETE"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:50:53Z"}