{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_4-1142"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_4-1142","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Camera calibration techniques","abstract":"In order to facilitate the implementation of RAC-based camera calibration technique, several issues are addressed in this thesis. First, a straightforward extension of the RAC-based camera calibration technique to the case of unknown camera specifications is given. Second, to speed up the calibration process and reduce numerical difficulties, a simplified RAC-based method is presented. The simplified RAC-based method provides a closed-form solution to the camera calibration problem. Third, the PTM-based camera calibration technique is presented to give an example of pre-1985 camera calibration technique. Fourth, a method is devised to compute the ratio of scale factors. Finally, an optimization scheme is suggested to estimate image center. These modifications preserve all the advantages possessed by the original RAC-based calibration technique. The experiment results are provided to illustrate the effectiveness of the present methods.","abstract_html":"In order to facilitate the implementation of RAC-based camera calibration technique, several issues are addressed in this thesis. First, a straightforward extension of the RAC-based camera calibration technique to the case of unknown camera specifications is given. Second, to speed up the calibration process and reduce numerical difficulties, a simplified RAC-based method is presented. The simplified RAC-based method provides a closed-form solution to the camera calibration problem. Third, the PTM-based camera calibration technique is presented to give an example of pre-1985 camera calibration technique. Fourth, a method is devised to compute the ratio of scale factors. Finally, an optimization scheme is suggested to estimate image center. These modifications preserve all the advantages possessed by the original RAC-based calibration technique. The experiment results are provided to illustrate the effectiveness of the present methods.","abstract_has_math":false,"creators":["Xu, Xuan."],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:53:41Z","subjects":["Cameras--Calibration"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_4/143","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_4/143","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_4-1142","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_4-1142","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Xu, Xuan."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1991-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Cameras--Calibration"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_4/143"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In order to facilitate the implementation of RAC-based camera calibration technique, several issues are addressed in this thesis. First, a straightforward extension of the RAC-based camera calibration technique to the case of unknown camera specifications is given. Second, to speed up the calibration process and reduce numerical difficulties, a simplified RAC-based method is presented. The simplified RAC-based method provides a closed-form solution to the camera calibration problem. Third, the PTM-based camera calibration technique is presented to give an example of pre-1985 camera calibration technique. Fourth, a method is devised to compute the ratio of scale factors. Finally, an optimization scheme is suggested to estimate image center. These modifications preserve all the advantages possessed by the original RAC-based calibration technique. The experiment results are provided to illustrate the effectiveness of the present methods."]},{"key":"dc:description.note","label":"Dc Description Note","values":["College of Engineering and Computer Science|FAU Electronic Theses and Dissertations Collection|Thesis (M.S.E.)--Florida Atlantic University, 1991.|College of Engineering and Computer Science"]},{"key":"dc:title","label":"Title","values":["Camera calibration techniques"]}]}],"canonical_facts":{"dc:creator":["Xu, Xuan."],"dc:date.created":["1991-01-01T08:00:00Z"],"dc:description.abstract":["In order to facilitate the implementation of RAC-based camera calibration technique, several issues are addressed in this thesis. First, a straightforward extension of the RAC-based camera calibration technique to the case of unknown camera specifications is given. Second, to speed up the calibration process and reduce numerical difficulties, a simplified RAC-based method is presented. The simplified RAC-based method provides a closed-form solution to the camera calibration problem. Third, the PTM-based camera calibration technique is presented to give an example of pre-1985 camera calibration technique. Fourth, a method is devised to compute the ratio of scale factors. Finally, an optimization scheme is suggested to estimate image center. These modifications preserve all the advantages possessed by the original RAC-based calibration technique. The experiment results are provided to illustrate the effectiveness of the present methods."],"dc:description.note":["College of Engineering and Computer Science|FAU Electronic Theses and Dissertations Collection|Thesis (M.S.E.)--Florida Atlantic University, 1991.|College of Engineering and Computer Science"],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_4/143"],"dc:subject":["Cameras--Calibration"],"dc:title":["Camera calibration techniques"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:53:41Z"}