{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_4-1163"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_4-1163","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Design and evaluation of a swirling flow combustion system","abstract":"A swirling flow combustion system has been designed and constructed. An integral laser Doppler velocimeter is constructed for the investigations of fluid mechanics aspects of a swirling flow combustor. The combustor consists of one fuel flow and two swirled air flows. The inner air flow has a fixed swirling strength and the outer air flow has an adjustable swirler. Both counterswirl and coswirl flows with variable swirl strength can be generated. Premixed or non-premixed combustion can be investigated on this system. Evaluation of the swirling combustion system and performance check of the velocity measurement system are conducted. Detailed time mean and fluctuating flow measurements are obtained for coswirl and counterswirl conditions with the LDV system. A central recirculation zone is observed in both swirl conditions, but the size in counterswirl is much smaller. The reasons for the difference are discussed.","abstract_html":"A swirling flow combustion system has been designed and constructed. An integral laser Doppler velocimeter is constructed for the investigations of fluid mechanics aspects of a swirling flow combustor. The combustor consists of one fuel flow and two swirled air flows. The inner air flow has a fixed swirling strength and the outer air flow has an adjustable swirler. Both counterswirl and coswirl flows with variable swirl strength can be generated. Premixed or non-premixed combustion can be investigated on this system. Evaluation of the swirling combustion system and performance check of the velocity measurement system are conducted. Detailed time mean and fluctuating flow measurements are obtained for coswirl and counterswirl conditions with the LDV system. A central recirculation zone is observed in both swirl conditions, but the size in counterswirl is much smaller. The reasons for the difference are discussed.","abstract_has_math":false,"creators":["Li, Ceji."],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:53:47Z","subjects":["Fluid dynamics","Vortex-motion","Combustion chambers"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_4/164","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_4/164","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_4-1163","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_4-1163","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Li, Ceji."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1991-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fluid dynamics","Vortex-motion","Combustion chambers"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_4/164"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A swirling flow combustion system has been designed and constructed. An integral laser Doppler velocimeter is constructed for the investigations of fluid mechanics aspects of a swirling flow combustor. The combustor consists of one fuel flow and two swirled air flows. The inner air flow has a fixed swirling strength and the outer air flow has an adjustable swirler. Both counterswirl and coswirl flows with variable swirl strength can be generated. Premixed or non-premixed combustion can be investigated on this system. Evaluation of the swirling combustion system and performance check of the velocity measurement system are conducted. Detailed time mean and fluctuating flow measurements are obtained for coswirl and counterswirl conditions with the LDV system. A central recirculation zone is observed in both swirl conditions, but the size in counterswirl is much smaller. The reasons for the difference are discussed."]},{"key":"dc:description.note","label":"Dc Description Note","values":["College of Engineering and Computer Science|FAU Electronic Theses and Dissertations Collection|Thesis (M.S.)--Florida Atlantic University, 1991.|College of Engineering and Computer Science"]},{"key":"dc:title","label":"Title","values":["Design and evaluation of a swirling flow combustion system"]}]}],"canonical_facts":{"dc:creator":["Li, Ceji."],"dc:date.created":["1991-01-01T08:00:00Z"],"dc:description.abstract":["A swirling flow combustion system has been designed and constructed. An integral laser Doppler velocimeter is constructed for the investigations of fluid mechanics aspects of a swirling flow combustor. The combustor consists of one fuel flow and two swirled air flows. The inner air flow has a fixed swirling strength and the outer air flow has an adjustable swirler. Both counterswirl and coswirl flows with variable swirl strength can be generated. Premixed or non-premixed combustion can be investigated on this system. Evaluation of the swirling combustion system and performance check of the velocity measurement system are conducted. Detailed time mean and fluctuating flow measurements are obtained for coswirl and counterswirl conditions with the LDV system. A central recirculation zone is observed in both swirl conditions, but the size in counterswirl is much smaller. The reasons for the difference are discussed."],"dc:description.note":["College of Engineering and Computer Science|FAU Electronic Theses and Dissertations Collection|Thesis (M.S.)--Florida Atlantic University, 1991.|College of Engineering and Computer Science"],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_4/164"],"dc:subject":["Fluid dynamics","Vortex-motion","Combustion chambers"],"dc:title":["Design and evaluation of a swirling flow combustion system"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:53:47Z"}