{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_4-1752"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_4-1752","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"electromagnetic code evaluation in the 100 MHz to 1000 MHz region","abstract":"For certain wavelength size objects, the frequency range between 100 MHz and 1000 MHz spans a transition region when using low frequency electromagnetic scattering codes based on Method of Moments (MoM) to high frequency codes based on Physical Theory of Diffraction (PTD) and ray tracing techniques. As the wavelength size of the object increased, MoM codes can require prohibitively long computational times and hence the more approximate high frequency codes become more attractive. The Ohio State Material Wire code (MATWRS) was selected as a representative MoM code for characterizing the transition region. XPATCH was selected as a representative high frequency code with ACAD used as the general modeling program. To evaluate these codes, a comparison of Radar Cross Section (RCS) predictions for simple PEC canonical shapes was made. Comparisons were made to both measured data where available and predictions generated by the McDonnell Douglas Body of Revolution (BOR) code.","abstract_html":"For certain wavelength size objects, the frequency range between 100 MHz and 1000 MHz spans a transition region when using low frequency electromagnetic scattering codes based on Method of Moments (MoM) to high frequency codes based on Physical Theory of Diffraction (PTD) and ray tracing techniques. As the wavelength size of the object increased, MoM codes can require prohibitively long computational times and hence the more approximate high frequency codes become more attractive. The Ohio State Material Wire code (MATWRS) was selected as a representative MoM code for characterizing the transition region. XPATCH was selected as a representative high frequency code with ACAD used as the general modeling program. To evaluate these codes, a comparison of Radar Cross Section (RCS) predictions for simple PEC canonical shapes was made. Comparisons were made to both measured data where available and predictions generated by the McDonnell Douglas Body of Revolution (BOR) code.","abstract_has_math":false,"creators":["Casciato, Mark D"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:54:45Z","subjects":["Computer-aided design","Radar cross sections","Electromagnetic waves","Moments method (Statistics)"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_4/753","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_4/753","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_4-1752","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_4-1752","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Casciato, Mark D"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1995-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Computer-aided design","Radar cross sections","Electromagnetic waves","Moments method (Statistics)"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_4/753"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["For certain wavelength size objects, the frequency range between 100 MHz and 1000 MHz spans a transition region when using low frequency electromagnetic scattering codes based on Method of Moments (MoM) to high frequency codes based on Physical Theory of Diffraction (PTD) and ray tracing techniques. As the wavelength size of the object increased, MoM codes can require prohibitively long computational times and hence the more approximate high frequency codes become more attractive. The Ohio State Material Wire code (MATWRS) was selected as a representative MoM code for characterizing the transition region. XPATCH was selected as a representative high frequency code with ACAD used as the general modeling program. To evaluate these codes, a comparison of Radar Cross Section (RCS) predictions for simple PEC canonical shapes was made. Comparisons were made to both measured data where available and predictions generated by the McDonnell Douglas Body of Revolution (BOR) code."]},{"key":"dc:description.note","label":"Dc Description Note","values":["College of Engineering and Computer Science|FAU Electronic Theses and Dissertations Collection|Thesis (M.S.E.)--Florida Atlantic University, 1995.|College of Engineering and Computer Science"]},{"key":"dc:title","label":"Title","values":["electromagnetic code evaluation in the 100 MHz to 1000 MHz region"]}]}],"canonical_facts":{"dc:creator":["Casciato, Mark D"],"dc:date.created":["1995-01-01T08:00:00Z"],"dc:description.abstract":["For certain wavelength size objects, the frequency range between 100 MHz and 1000 MHz spans a transition region when using low frequency electromagnetic scattering codes based on Method of Moments (MoM) to high frequency codes based on Physical Theory of Diffraction (PTD) and ray tracing techniques. As the wavelength size of the object increased, MoM codes can require prohibitively long computational times and hence the more approximate high frequency codes become more attractive. The Ohio State Material Wire code (MATWRS) was selected as a representative MoM code for characterizing the transition region. XPATCH was selected as a representative high frequency code with ACAD used as the general modeling program. To evaluate these codes, a comparison of Radar Cross Section (RCS) predictions for simple PEC canonical shapes was made. Comparisons were made to both measured data where available and predictions generated by the McDonnell Douglas Body of Revolution (BOR) code."],"dc:description.note":["College of Engineering and Computer Science|FAU Electronic Theses and Dissertations Collection|Thesis (M.S.E.)--Florida Atlantic University, 1995.|College of Engineering and Computer Science"],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_4/753"],"dc:subject":["Computer-aided design","Radar cross sections","Electromagnetic waves","Moments method (Statistics)"],"dc:title":["electromagnetic code evaluation in the 100 MHz to 1000 MHz region"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:54:45Z"}