{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_4-1884"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_4-1884","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Comparison of alkyl-bonded alumina and silica stationary phases for peptide and protein separations by high performance liquid chromatography","abstract":"The applicability of a recently developed octadecylalumina (ODA) stationary phase for the preparative separations of proteins and peptides is compared with that of conventional Octadecylsilica (ODS) phases. Chromatographic peak widths, peaks areas, and recoveries of polypeptides were obtained from both types of phases. The ODA phase compares favorably with the ODS phase on small peptides, but exhibits low recoveries on high molecular weight proteins. The results are attributed to the unique fused-microplatelet shape of the ODA particles.","abstract_html":"The applicability of a recently developed octadecylalumina (ODA) stationary phase for the preparative separations of proteins and peptides is compared with that of conventional Octadecylsilica (ODS) phases. Chromatographic peak widths, peaks areas, and recoveries of polypeptides were obtained from both types of phases. The ODA phase compares favorably with the ODS phase on small peptides, but exhibits low recoveries on high molecular weight proteins. The results are attributed to the unique fused-microplatelet shape of the ODA particles.","abstract_has_math":false,"creators":["Williams, David Clinton"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:54:55Z","subjects":["High performance liquid chromatography","Proteins--Separation","Peptides--Separation"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_4/885","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_4/885","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_4-1884","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_4-1884","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Williams, David Clinton"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1996-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["High performance liquid chromatography","Proteins--Separation","Peptides--Separation"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_4/885"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The applicability of a recently developed octadecylalumina (ODA) stationary phase for the preparative separations of proteins and peptides is compared with that of conventional Octadecylsilica (ODS) phases. Chromatographic peak widths, peaks areas, and recoveries of polypeptides were obtained from both types of phases. The ODA phase compares favorably with the ODS phase on small peptides, but exhibits low recoveries on high molecular weight proteins. The results are attributed to the unique fused-microplatelet shape of the ODA particles."]},{"key":"dc:description.note","label":"Dc Description Note","values":["Thesis (M.S.)--Florida Atlantic University, 1996.|Thesis (M.S.)--Florida Atlantic University, 1996."]},{"key":"dc:title","label":"Title","values":["Comparison of alkyl-bonded alumina and silica stationary phases for peptide and protein separations by high performance liquid chromatography"]}]}],"canonical_facts":{"dc:creator":["Williams, David Clinton"],"dc:date.created":["1996-01-01T08:00:00Z"],"dc:description.abstract":["The applicability of a recently developed octadecylalumina (ODA) stationary phase for the preparative separations of proteins and peptides is compared with that of conventional Octadecylsilica (ODS) phases. Chromatographic peak widths, peaks areas, and recoveries of polypeptides were obtained from both types of phases. The ODA phase compares favorably with the ODS phase on small peptides, but exhibits low recoveries on high molecular weight proteins. The results are attributed to the unique fused-microplatelet shape of the ODA particles."],"dc:description.note":["Thesis (M.S.)--Florida Atlantic University, 1996.|Thesis (M.S.)--Florida Atlantic University, 1996."],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_4/885"],"dc:subject":["High performance liquid chromatography","Proteins--Separation","Peptides--Separation"],"dc:title":["Comparison of alkyl-bonded alumina and silica stationary phases for peptide and protein separations by high performance liquid chromatography"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:54:55Z"}