{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_4-2125"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_4-2125","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Embrittlement susceptibility of corroded pre-stressing steel in concrete during cathodic polarization","abstract":"Experiments and analyses were performed to better define the limits of concern regarding hydrogen embrittlement in association with application of cathodic protection to prestressed concrete. To accomplish this, prestressed concrete specimens were locally corroded to different levels by anodic polarization and then polarized to -1.30 V SCE. A procedure of examination was developed using strain gauges to determine the level of prestrain. Relatively few brittle failures of wires resulted due, at least in part, to a relatively low prestrain of the pretensioned tendons. A model was developed which, coupled with data from parallel research, permitted definition of the minimum cross section for brittle failure as a function of the magnitude of prestrain and corrosion morphology of the wire. These results were tabulated in a format that can be used during field inspection to identify structural elements for which fracture could occur upon application of cathodic protection.","abstract_html":"Experiments and analyses were performed to better define the limits of concern regarding hydrogen embrittlement in association with application of cathodic protection to prestressed concrete. To accomplish this, prestressed concrete specimens were locally corroded to different levels by anodic polarization and then polarized to -1.30 V SCE. A procedure of examination was developed using strain gauges to determine the level of prestrain. Relatively few brittle failures of wires resulted due, at least in part, to a relatively low prestrain of the pretensioned tendons. A model was developed which, coupled with data from parallel research, permitted definition of the minimum cross section for brittle failure as a function of the magnitude of prestrain and corrosion morphology of the wire. These results were tabulated in a format that can be used during field inspection to identify structural elements for which fracture could occur upon application of cathodic protection.","abstract_has_math":false,"creators":["Poeydomenge, Arnaud."],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:55:20Z","subjects":["Prestressed concrete--Corrosion","Cathodic protection","Prestressed concrete--Embrittlement","Prestressed steel construction"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_4/1126","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_4/1126","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_4-2125","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_4-2125","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Poeydomenge, Arnaud."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1997-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Prestressed concrete--Corrosion","Cathodic protection","Prestressed concrete--Embrittlement","Prestressed steel construction"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_4/1126"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Experiments and analyses were performed to better define the limits of concern regarding hydrogen embrittlement in association with application of cathodic protection to prestressed concrete. To accomplish this, prestressed concrete specimens were locally corroded to different levels by anodic polarization and then polarized to -1.30 V SCE. A procedure of examination was developed using strain gauges to determine the level of prestrain. Relatively few brittle failures of wires resulted due, at least in part, to a relatively low prestrain of the pretensioned tendons. A model was developed which, coupled with data from parallel research, permitted definition of the minimum cross section for brittle failure as a function of the magnitude of prestrain and corrosion morphology of the wire. These results were tabulated in a format that can be used during field inspection to identify structural elements for which fracture could occur upon application of cathodic protection."]},{"key":"dc:description.note","label":"Dc Description Note","values":["College of Engineering and Computer Science|FAU Electronic Theses and Dissertations Collection|Thesis (M.S.E.)--Florida Atlantic University, 1997.|College of Engineering and Computer Science"]},{"key":"dc:title","label":"Title","values":["Embrittlement susceptibility of corroded pre-stressing steel in concrete during cathodic polarization"]}]}],"canonical_facts":{"dc:creator":["Poeydomenge, Arnaud."],"dc:date.created":["1997-01-01T08:00:00Z"],"dc:description.abstract":["Experiments and analyses were performed to better define the limits of concern regarding hydrogen embrittlement in association with application of cathodic protection to prestressed concrete. To accomplish this, prestressed concrete specimens were locally corroded to different levels by anodic polarization and then polarized to -1.30 V SCE. A procedure of examination was developed using strain gauges to determine the level of prestrain. Relatively few brittle failures of wires resulted due, at least in part, to a relatively low prestrain of the pretensioned tendons. A model was developed which, coupled with data from parallel research, permitted definition of the minimum cross section for brittle failure as a function of the magnitude of prestrain and corrosion morphology of the wire. These results were tabulated in a format that can be used during field inspection to identify structural elements for which fracture could occur upon application of cathodic protection."],"dc:description.note":["College of Engineering and Computer Science|FAU Electronic Theses and Dissertations Collection|Thesis (M.S.E.)--Florida Atlantic University, 1997.|College of Engineering and Computer Science"],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_4/1126"],"dc:subject":["Prestressed concrete--Corrosion","Cathodic protection","Prestressed concrete--Embrittlement","Prestressed steel construction"],"dc:title":["Embrittlement susceptibility of corroded pre-stressing steel in concrete during cathodic polarization"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:55:20Z"}