{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_4-2541"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_4-2541","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"The effects of an external nasal dilator on the work of breathing during exercise","abstract":"Effects of an external nasal dilator on the work of breathing was measured during exercise in 14 untrained students (age, 24 $\\pm$ 3 yr.). Two maximal, incremental ergometer tests were performed to exhaustion. Subjects wore a placebo or an active nasal dilator strip, in random order, during each test. Measurement of inspiratory elastic work (inew), inspiratory resistive work (inrw), and expiratory resistive work (exrw) was done using an esophageal balloon. Measured variables included VO$\\sb2$, V$\\rm\\sb{E}$, V$\\rm\\sb{T}$, frequency of breathing (f), inew, inrw, and exrw, (work expressed in joules). There were no significant differences in VO$\\sb2$, V$\\rm\\sb{E}$, V$\\rm\\sb{T}$ or f between groups ($\\rm p>0.05$). No significant difference was found at peak exercise between groups (mean $\\pm$ SD; Placebo; inew, $1.1\\pm0.6$ J, inrw, $1.4\\pm0.8$ J, exrw $2.2\\pm1.8$ J; Active; inew, $1.0\\pm0.5$ J, inrw, $1.3\\pm0.7$ J, exrw, $1.8\\pm0.9$ J; $\\rm p>0.05$). Wearing an external nasal dilator does not significantly reduce the work of breathing during exercise.","abstract_html":"Effects of an external nasal dilator on the work of breathing was measured during exercise in 14 untrained students (age, 24 $\\pm$ 3 yr.). Two maximal, incremental ergometer tests were performed to exhaustion. Subjects wore a placebo or an active nasal dilator strip, in random order, during each test. Measurement of inspiratory elastic work (inew), inspiratory resistive work (inrw), and expiratory resistive work (exrw) was done using an esophageal balloon. Measured variables included VO$\\sb2$, V$\\rm\\sb{E}$, V$\\rm\\sb{T}$, frequency of breathing (f), inew, inrw, and exrw, (work expressed in joules). There were no significant differences in VO$\\sb2$, V$\\rm\\sb{E}$, V$\\rm\\sb{T}$ or f between groups ($\\rm p&gt;0.05$). No significant difference was found at peak exercise between groups (mean $\\pm$ SD; Placebo; inew, $1.1\\pm0.6$ J, inrw, $1.4\\pm0.8$ J, exrw $2.2\\pm1.8$ J; Active; inew, $1.0\\pm0.5$ J, inrw, $1.3\\pm0.7$ J, exrw, $1.8\\pm0.9$ J; $\\rm p&gt;0.05$). Wearing an external nasal dilator does not significantly reduce the work of breathing during exercise.","abstract_has_math":true,"creators":["James, Todd Robert"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:55:59Z","subjects":["Respiration--Measurement","Exercise--Physiological aspects"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_4/1542","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_4/1542","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_4-2541","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_4-2541","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["James, Todd Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1999-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Respiration--Measurement","Exercise--Physiological aspects"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_4/1542"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Effects of an external nasal dilator on the work of breathing was measured during exercise in 14 untrained students (age, 24 $\\pm$ 3 yr.). Two maximal, incremental ergometer tests were performed to exhaustion. Subjects wore a placebo or an active nasal dilator strip, in random order, during each test. Measurement of inspiratory elastic work (inew), inspiratory resistive work (inrw), and expiratory resistive work (exrw) was done using an esophageal balloon. Measured variables included VO$\\sb2$, V$\\rm\\sb{E}$, V$\\rm\\sb{T}$, frequency of breathing (f), inew, inrw, and exrw, (work expressed in joules). There were no significant differences in VO$\\sb2$, V$\\rm\\sb{E}$, V$\\rm\\sb{T}$ or f between groups ($\\rm p>0.05$). No significant difference was found at peak exercise between groups (mean $\\pm$ SD; Placebo; inew, $1.1\\pm0.6$ J, inrw, $1.4\\pm0.8$ J, exrw $2.2\\pm1.8$ J; Active; inew, $1.0\\pm0.5$ J, inrw, $1.3\\pm0.7$ J, exrw, $1.8\\pm0.9$ J; $\\rm p>0.05$). Wearing an external nasal dilator does not significantly reduce the work of breathing during exercise."]},{"key":"dc:description.note","label":"Dc Description Note","values":["College of Education|Thesis (M.S.)--Florida Atlantic University, 1999.|College of Education"]},{"key":"dc:title","label":"Title","values":["The effects of an external nasal dilator on the work of breathing during exercise"]}]}],"canonical_facts":{"dc:creator":["James, Todd Robert"],"dc:date.created":["1999-01-01T08:00:00Z"],"dc:description.abstract":["Effects of an external nasal dilator on the work of breathing was measured during exercise in 14 untrained students (age, 24 $\\pm$ 3 yr.). Two maximal, incremental ergometer tests were performed to exhaustion. Subjects wore a placebo or an active nasal dilator strip, in random order, during each test. Measurement of inspiratory elastic work (inew), inspiratory resistive work (inrw), and expiratory resistive work (exrw) was done using an esophageal balloon. Measured variables included VO$\\sb2$, V$\\rm\\sb{E}$, V$\\rm\\sb{T}$, frequency of breathing (f), inew, inrw, and exrw, (work expressed in joules). There were no significant differences in VO$\\sb2$, V$\\rm\\sb{E}$, V$\\rm\\sb{T}$ or f between groups ($\\rm p>0.05$). No significant difference was found at peak exercise between groups (mean $\\pm$ SD; Placebo; inew, $1.1\\pm0.6$ J, inrw, $1.4\\pm0.8$ J, exrw $2.2\\pm1.8$ J; Active; inew, $1.0\\pm0.5$ J, inrw, $1.3\\pm0.7$ J, exrw, $1.8\\pm0.9$ J; $\\rm p>0.05$). Wearing an external nasal dilator does not significantly reduce the work of breathing during exercise."],"dc:description.note":["College of Education|Thesis (M.S.)--Florida Atlantic University, 1999.|College of Education"],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_4/1542"],"dc:subject":["Respiration--Measurement","Exercise--Physiological aspects"],"dc:title":["The effects of an external nasal dilator on the work of breathing during exercise"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:55:59Z"}