{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_5-1491"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_5-1491","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Analytical evaluation of marine concrete pile repairs","abstract":"The purpose of the thesis is to determine and compare the performance characteristics of marine piles corroded by chloride diffusion and repaired by several different methods for both uncracked and cracked concrete and to determine their structural integrity. The long-term objective is the comparison of the analytical values with those from an on-going experimental evaluation. The time for chloride concentration reach the threshold value that initiates corrosion in the reinforcement has been determined by Fick's law, extended to 2-D and 3-D chloride diffusion, for (a) uncracked concrete, and (b) for cracked concrete with the Simplified Smeared Approach (SSA). The structural integrity of the concrete circular pile is compared before and alter repair, by (a) finite element modeling using ANSYS software with the maximum deflection, and (b) beam strength analysis to find the moment capacity for cracked and ultimate conditions. The overall findings indicate the adequacy of the repair procedures.","abstract_html":"The purpose of the thesis is to determine and compare the performance characteristics of marine piles corroded by chloride diffusion and repaired by several different methods for both uncracked and cracked concrete and to determine their structural integrity. The long-term objective is the comparison of the analytical values with those from an on-going experimental evaluation. The time for chloride concentration reach the threshold value that initiates corrosion in the reinforcement has been determined by Fick&#x27;s law, extended to 2-D and 3-D chloride diffusion, for (a) uncracked concrete, and (b) for cracked concrete with the Simplified Smeared Approach (SSA). The structural integrity of the concrete circular pile is compared before and alter repair, by (a) finite element modeling using ANSYS software with the maximum deflection, and (b) beam strength analysis to find the moment capacity for cracked and ultimate conditions. The overall findings indicate the adequacy of the repair procedures.","abstract_has_math":false,"creators":["Saleh, Zaher A Abou"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:54:20Z","subjects":["Concrete piling","Reinforced concrete--Corrosion","Seawater corrosion"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_5/492","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_5/492","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_5-1491","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_5-1491","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Saleh, Zaher A Abou"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2003-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Concrete piling","Reinforced concrete--Corrosion","Seawater corrosion"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_5/492"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of the thesis is to determine and compare the performance characteristics of marine piles corroded by chloride diffusion and repaired by several different methods for both uncracked and cracked concrete and to determine their structural integrity. The long-term objective is the comparison of the analytical values with those from an on-going experimental evaluation. The time for chloride concentration reach the threshold value that initiates corrosion in the reinforcement has been determined by Fick's law, extended to 2-D and 3-D chloride diffusion, for (a) uncracked concrete, and (b) for cracked concrete with the Simplified Smeared Approach (SSA). The structural integrity of the concrete circular pile is compared before and alter repair, by (a) finite element modeling using ANSYS software with the maximum deflection, and (b) beam strength analysis to find the moment capacity for cracked and ultimate conditions. The overall findings indicate the adequacy of the repair procedures."]},{"key":"dc:description.note","label":"Dc Description Note","values":["College of Engineering and Computer Science|FAU Electronic Theses and Dissertations Collection|Thesis (M.S.)--Florida Atlantic University, 2003.|College of Engineering and Computer Science"]},{"key":"dc:title","label":"Title","values":["Analytical evaluation of marine concrete pile repairs"]}]}],"canonical_facts":{"dc:creator":["Saleh, Zaher A Abou"],"dc:date.created":["2003-01-01T08:00:00Z"],"dc:description.abstract":["The purpose of the thesis is to determine and compare the performance characteristics of marine piles corroded by chloride diffusion and repaired by several different methods for both uncracked and cracked concrete and to determine their structural integrity. The long-term objective is the comparison of the analytical values with those from an on-going experimental evaluation. The time for chloride concentration reach the threshold value that initiates corrosion in the reinforcement has been determined by Fick's law, extended to 2-D and 3-D chloride diffusion, for (a) uncracked concrete, and (b) for cracked concrete with the Simplified Smeared Approach (SSA). The structural integrity of the concrete circular pile is compared before and alter repair, by (a) finite element modeling using ANSYS software with the maximum deflection, and (b) beam strength analysis to find the moment capacity for cracked and ultimate conditions. The overall findings indicate the adequacy of the repair procedures."],"dc:description.note":["College of Engineering and Computer Science|FAU Electronic Theses and Dissertations Collection|Thesis (M.S.)--Florida Atlantic University, 2003.|College of Engineering and Computer Science"],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_5/492"],"dc:subject":["Concrete piling","Reinforced concrete--Corrosion","Seawater corrosion"],"dc:title":["Analytical evaluation of marine concrete pile repairs"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:54:20Z"}