{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_5-1755"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_5-1755","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Oxygenated water and exercise performance","abstract":"The purpose of this study was to determine the effect of oxygenated water on endurance exercise performance. Subjects (N=15, VO2max 54.8 +/- 5.8 ml/kg/min) were tested using non-oxygenated water (PL) and oxygenated water (OW). Two maximal exercise tests and 2 submaximal tests were conducted. VO2max (3.28 +/- 0.81 L/min (OW) vs. 3.30 +/- 0.80 L/min (PL)) VE, VO2, or R were not different. Submaximal blood lactate values at 60%, 80% of VO 2max (4.2 +/- 2.1 mMol/L, 6.6 +/- 2.9 mMol/L (OW) vs. 3.8 +/- 1.8 mMol/L, 6.1 +/- 2.4 mMol/L (PL)) and HR (140 +/- 15 bpm, 162 +/- 11 bpm (OW) vs. 138 +/- 15 bpm, 163 +/- 13 bpm (PL)) were not different and neither was time to exhaustion at 90% of VO 2max (5.22 +/- 2.31 min (OW) vs. 6.80 +/- 2.93 min (PL)). Oxygen content of OW (13.1 +/- 1.5 mgO2L-1 ) was higher than PL (6.0 +/- 0.1 mgO2L -1) (p<0.05) but lower than manufacture's claims. Thus, superoxygenated water did not result in any improvements in endurance exercise performance.","abstract_html":"The purpose of this study was to determine the effect of oxygenated water on endurance exercise performance. Subjects (N=15, VO2max 54.8 +/- 5.8 ml/kg/min) were tested using non-oxygenated water (PL) and oxygenated water (OW). Two maximal exercise tests and 2 submaximal tests were conducted. VO2max (3.28 +/- 0.81 L/min (OW) vs. 3.30 +/- 0.80 L/min (PL)) VE, VO2, or R were not different. Submaximal blood lactate values at 60%, 80% of VO 2max (4.2 +/- 2.1 mMol/L, 6.6 +/- 2.9 mMol/L (OW) vs. 3.8 +/- 1.8 mMol/L, 6.1 +/- 2.4 mMol/L (PL)) and HR (140 +/- 15 bpm, 162 +/- 11 bpm (OW) vs. 138 +/- 15 bpm, 163 +/- 13 bpm (PL)) were not different and neither was time to exhaustion at 90% of VO 2max (5.22 +/- 2.31 min (OW) vs. 6.80 +/- 2.93 min (PL)). Oxygen content of OW (13.1 +/- 1.5 mgO2L-1 ) was higher than PL (6.0 +/- 0.1 mgO2L -1) (p&lt;0.05) but lower than manufacture&#x27;s claims. Thus, superoxygenated water did not result in any improvements in endurance exercise performance.","abstract_has_math":false,"creators":["Mielke, Michelle."],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:54:45Z","subjects":["Oxygen--Physiological transport","Oxygen in the body","Exercise--Physiological aspects"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_5/756","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_5/756","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_5-1755","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_5-1755","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Mielke, Michelle."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2004-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Oxygen--Physiological transport","Oxygen in the body","Exercise--Physiological aspects"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_5/756"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this study was to determine the effect of oxygenated water on endurance exercise performance. Subjects (N=15, VO2max 54.8 +/- 5.8 ml/kg/min) were tested using non-oxygenated water (PL) and oxygenated water (OW). Two maximal exercise tests and 2 submaximal tests were conducted. VO2max (3.28 +/- 0.81 L/min (OW) vs. 3.30 +/- 0.80 L/min (PL)) VE, VO2, or R were not different. Submaximal blood lactate values at 60%, 80% of VO 2max (4.2 +/- 2.1 mMol/L, 6.6 +/- 2.9 mMol/L (OW) vs. 3.8 +/- 1.8 mMol/L, 6.1 +/- 2.4 mMol/L (PL)) and HR (140 +/- 15 bpm, 162 +/- 11 bpm (OW) vs. 138 +/- 15 bpm, 163 +/- 13 bpm (PL)) were not different and neither was time to exhaustion at 90% of VO 2max (5.22 +/- 2.31 min (OW) vs. 6.80 +/- 2.93 min (PL)). Oxygen content of OW (13.1 +/- 1.5 mgO2L-1 ) was higher than PL (6.0 +/- 0.1 mgO2L -1) (p<0.05) but lower than manufacture's claims. Thus, superoxygenated water did not result in any improvements in endurance exercise performance."]},{"key":"dc:description.note","label":"Dc Description Note","values":["College of Education|Thesis (M.S.)--Florida Atlantic University, 2004.|College of Education"]},{"key":"dc:title","label":"Title","values":["Oxygenated water and exercise performance"]}]}],"canonical_facts":{"dc:creator":["Mielke, Michelle."],"dc:date.created":["2004-01-01T08:00:00Z"],"dc:description.abstract":["The purpose of this study was to determine the effect of oxygenated water on endurance exercise performance. Subjects (N=15, VO2max 54.8 +/- 5.8 ml/kg/min) were tested using non-oxygenated water (PL) and oxygenated water (OW). Two maximal exercise tests and 2 submaximal tests were conducted. VO2max (3.28 +/- 0.81 L/min (OW) vs. 3.30 +/- 0.80 L/min (PL)) VE, VO2, or R were not different. Submaximal blood lactate values at 60%, 80% of VO 2max (4.2 +/- 2.1 mMol/L, 6.6 +/- 2.9 mMol/L (OW) vs. 3.8 +/- 1.8 mMol/L, 6.1 +/- 2.4 mMol/L (PL)) and HR (140 +/- 15 bpm, 162 +/- 11 bpm (OW) vs. 138 +/- 15 bpm, 163 +/- 13 bpm (PL)) were not different and neither was time to exhaustion at 90% of VO 2max (5.22 +/- 2.31 min (OW) vs. 6.80 +/- 2.93 min (PL)). Oxygen content of OW (13.1 +/- 1.5 mgO2L-1 ) was higher than PL (6.0 +/- 0.1 mgO2L -1) (p<0.05) but lower than manufacture's claims. Thus, superoxygenated water did not result in any improvements in endurance exercise performance."],"dc:description.note":["College of Education|Thesis (M.S.)--Florida Atlantic University, 2004.|College of Education"],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_5/756"],"dc:subject":["Oxygen--Physiological transport","Oxygen in the body","Exercise--Physiological aspects"],"dc:title":["Oxygenated water and exercise performance"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:54:45Z"}