{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_5-2353"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_5-2353","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Technical Feasibility of Nanofiltration Concentrate Treatment with Low Pressure Reverse Osmosis","abstract":"This study evaluated the technical feasibility o f increasing the typical water recovery of a pilot scale membrane system (85-90%) to 97% by treatment of nanofiltration concentrate with low-pressure reverse osmosis. The study used Biscayne aquifer water (freshwater), and determined that it may be technically feasible to increase the recovery up to approximately 95% when the RO flux is —10 gfd, the feed water pH is reduced to -6.1 with H2 SO4 , and antiscalant in the NF process. The tested membranes showed stable and similar performance under the pilot conditions. However, pilot tests were sensitive to pH variations (pH>6.2). The main barrier for increasing the water recovery was fouling caused by iron, carbonate hardness, and iron bacteria. A preliminary cost analysis showed that there is an apparent econom ic advantage when the recovery is greater than 90%. Estimated water cost at 95% recovery is $1.99 compared with $2.69 at the typical 85% recovery.","abstract_html":"This study evaluated the technical feasibility o f increasing the typical water recovery of a pilot scale membrane system (85-90%) to 97% by treatment of nanofiltration concentrate with low-pressure reverse osmosis. The study used Biscayne aquifer water (freshwater), and determined that it may be technically feasible to increase the recovery up to approximately 95% when the RO flux is —10 gfd, the feed water pH is reduced to -6.1 with H2 SO4 , and antiscalant in the NF process. The tested membranes showed stable and similar performance under the pilot conditions. However, pilot tests were sensitive to pH variations (pH&gt;6.2). The main barrier for increasing the water recovery was fouling caused by iron, carbonate hardness, and iron bacteria. A preliminary cost analysis showed that there is an apparent econom ic advantage when the recovery is greater than 90%. Estimated water cost at 95% recovery is $1.99 compared with $2.69 at the typical 85% recovery.","abstract_has_math":true,"creators":["Toro, Adriana M"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:55:44Z","subjects":["Saline water conversion--Reverse osmosis process","Water--Purification--Reverse osmosis process","Membrane separation","Membranes (Technology)"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_5/1354","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_5/1354","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_5-2353","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_5-2353","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Toro, Adriana M"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2007-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Saline water conversion--Reverse osmosis process","Water--Purification--Reverse osmosis process","Membrane separation","Membranes (Technology)"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_5/1354"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study evaluated the technical feasibility o f increasing the typical water recovery of a pilot scale membrane system (85-90%) to 97% by treatment of nanofiltration concentrate with low-pressure reverse osmosis. The study used Biscayne aquifer water (freshwater), and determined that it may be technically feasible to increase the recovery up to approximately 95% when the RO flux is —10 gfd, the feed water pH is reduced to -6.1 with H2 SO4 , and antiscalant in the NF process. The tested membranes showed stable and similar performance under the pilot conditions. However, pilot tests were sensitive to pH variations (pH>6.2). The main barrier for increasing the water recovery was fouling caused by iron, carbonate hardness, and iron bacteria. A preliminary cost analysis showed that there is an apparent econom ic advantage when the recovery is greater than 90%. Estimated water cost at 95% recovery is $1.99 compared with $2.69 at the typical 85% recovery."]},{"key":"dc:description.note","label":"Dc Description Note","values":["College of Engineering and Computer Science|Thesis (M.S.)--Florida Atlantic University, 2007.|FAU Electronic Theses and Dissertations Collection|College of Engineering and Computer Science"]},{"key":"dc:title","label":"Title","values":["Technical Feasibility of Nanofiltration Concentrate Treatment with Low Pressure Reverse Osmosis"]}]}],"canonical_facts":{"dc:creator":["Toro, Adriana M"],"dc:date.created":["2007-01-01T08:00:00Z"],"dc:description.abstract":["This study evaluated the technical feasibility o f increasing the typical water recovery of a pilot scale membrane system (85-90%) to 97% by treatment of nanofiltration concentrate with low-pressure reverse osmosis. The study used Biscayne aquifer water (freshwater), and determined that it may be technically feasible to increase the recovery up to approximately 95% when the RO flux is —10 gfd, the feed water pH is reduced to -6.1 with H2 SO4 , and antiscalant in the NF process. The tested membranes showed stable and similar performance under the pilot conditions. However, pilot tests were sensitive to pH variations (pH>6.2). The main barrier for increasing the water recovery was fouling caused by iron, carbonate hardness, and iron bacteria. A preliminary cost analysis showed that there is an apparent econom ic advantage when the recovery is greater than 90%. Estimated water cost at 95% recovery is $1.99 compared with $2.69 at the typical 85% recovery."],"dc:description.note":["College of Engineering and Computer Science|Thesis (M.S.)--Florida Atlantic University, 2007.|FAU Electronic Theses and Dissertations Collection|College of Engineering and Computer Science"],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_5/1354"],"dc:subject":["Saline water conversion--Reverse osmosis process","Water--Purification--Reverse osmosis process","Membrane separation","Membranes (Technology)"],"dc:title":["Technical Feasibility of Nanofiltration Concentrate Treatment with Low Pressure Reverse Osmosis"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:55:44Z"}