{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_5-2569"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_5-2569","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Study and Design of a PIFA for a Human-Implanted RFID Communication System","abstract":"This effort studies the implementation of a biocompatible Planar Inverted-F Antenna (PIF A) for the Medical Instrument Communication System (MICS) frequency band of 402 to 405 MHz for RFID applications. The basic electromagnetic properties of human tissues are investigated at 403 .5 MHz. Then, the radiation characteristics of submerged wire antenna are evaluated in order to approximate the effects of multilayered media on a PIFA's performance. The PIFA is assessed using Ansoft's Finite Element Method based electromagnetic evaluation software, HFSS v.l 0. The electrical parameters of the antenna in relation to the surrounding environment, notably air, silicone capsule, and a three-layered bio-media, are presented. The analysis shows that the resonant frequency as well as the electrical performance of the design is significantly affected by the physical dimensions and the relative permittivity of the dielectric materials covering the antenna.","abstract_html":"This effort studies the implementation of a biocompatible Planar Inverted-F Antenna (PIF A) for the Medical Instrument Communication System (MICS) frequency band of 402 to 405 MHz for RFID applications. The basic electromagnetic properties of human tissues are investigated at 403 .5 MHz. Then, the radiation characteristics of submerged wire antenna are evaluated in order to approximate the effects of multilayered media on a PIFA&#x27;s performance. The PIFA is assessed using Ansoft&#x27;s Finite Element Method based electromagnetic evaluation software, HFSS v.l 0. The electrical parameters of the antenna in relation to the surrounding environment, notably air, silicone capsule, and a three-layered bio-media, are presented. The analysis shows that the resonant frequency as well as the electrical performance of the design is significantly affected by the physical dimensions and the relative permittivity of the dielectric materials covering the antenna.","abstract_has_math":false,"creators":["Jean-Charles, Yves-Thierry"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:56:04Z","subjects":["Radio frequency identification systems--Design","Antenna arrays--Design","Medical telematics","Health services administration--Technological innovations"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_5/1570","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_5/1570","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_5-2569","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_5-2569","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Jean-Charles, Yves-Thierry"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2008-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Radio frequency identification systems--Design","Antenna arrays--Design","Medical telematics","Health services administration--Technological innovations"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_5/1570"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This effort studies the implementation of a biocompatible Planar Inverted-F Antenna (PIF A) for the Medical Instrument Communication System (MICS) frequency band of 402 to 405 MHz for RFID applications. The basic electromagnetic properties of human tissues are investigated at 403 .5 MHz. Then, the radiation characteristics of submerged wire antenna are evaluated in order to approximate the effects of multilayered media on a PIFA's performance. The PIFA is assessed using Ansoft's Finite Element Method based electromagnetic evaluation software, HFSS v.l 0. The electrical parameters of the antenna in relation to the surrounding environment, notably air, silicone capsule, and a three-layered bio-media, are presented. The analysis shows that the resonant frequency as well as the electrical performance of the design is significantly affected by the physical dimensions and the relative permittivity of the dielectric materials covering the antenna."]},{"key":"dc:description.note","label":"Dc Description Note","values":["College of Engineering and Computer Science|Thesis (M.S.)--Florida Atlantic University, 2008.|FAU Electronic Theses and Dissertations Collection|College of Engineering and Computer Science"]},{"key":"dc:title","label":"Title","values":["Study and Design of a PIFA for a Human-Implanted RFID Communication System"]}]}],"canonical_facts":{"dc:creator":["Jean-Charles, Yves-Thierry"],"dc:date.created":["2008-01-01T08:00:00Z"],"dc:description.abstract":["This effort studies the implementation of a biocompatible Planar Inverted-F Antenna (PIF A) for the Medical Instrument Communication System (MICS) frequency band of 402 to 405 MHz for RFID applications. The basic electromagnetic properties of human tissues are investigated at 403 .5 MHz. Then, the radiation characteristics of submerged wire antenna are evaluated in order to approximate the effects of multilayered media on a PIFA's performance. The PIFA is assessed using Ansoft's Finite Element Method based electromagnetic evaluation software, HFSS v.l 0. The electrical parameters of the antenna in relation to the surrounding environment, notably air, silicone capsule, and a three-layered bio-media, are presented. The analysis shows that the resonant frequency as well as the electrical performance of the design is significantly affected by the physical dimensions and the relative permittivity of the dielectric materials covering the antenna."],"dc:description.note":["College of Engineering and Computer Science|Thesis (M.S.)--Florida Atlantic University, 2008.|FAU Electronic Theses and Dissertations Collection|College of Engineering and Computer Science"],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_5/1570"],"dc:subject":["Radio frequency identification systems--Design","Antenna arrays--Design","Medical telematics","Health services administration--Technological innovations"],"dc:title":["Study and Design of a PIFA for a Human-Implanted RFID Communication System"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:56:04Z"}