{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_6-1874"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_6-1874","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Studies of nanoparticle reinforced polymer coatings for trace gas detection","abstract":"With the goal of improving chemical detection methods for buried improvised explosive devices (IED’s), the intention of this study is to show that functionalized nano-particles improve the sensing properties of a polymer applied to gas sensors. The approach was reinforcing the polymer, Nafion, with acid-functionalized carbon nanotubes (CNT’s). Ammonia was chosen as the analyte for its similarity to IED byproducts without the dangers of toxicity or explosion. Two sensor platforms were investigated: Quartz crystal microbalances (QCM’s) and microcantilevers (MC’s). Preliminary evaluation of treated QCM’s, via frequency analyzer, showed improvements in sensitivity and fast reversal of adsorption; and suggested increased stability. Tests with coated MC’s also supported the findings of QCM tests. Amplitude response of MC’s was on average 4 times greater when the Nafion coating contained CNT’s. Quantitative QCM testing with gas-flow meters showed that with CNT inclusion: the average number of moles adsorbed increased by 35% (>1.2 times frequency response); sensitivity improved by 0.63 Hz/ppt on average; although the detection threshold decreased marginally; but reusability was much better after extended exposures to concentrated ammonia.","abstract_html":"With the goal of improving chemical detection methods for buried improvised explosive devices (IED’s), the intention of this study is to show that functionalized nano-particles improve the sensing properties of a polymer applied to gas sensors. The approach was reinforcing the polymer, Nafion, with acid-functionalized carbon nanotubes (CNT’s). Ammonia was chosen as the analyte for its similarity to IED byproducts without the dangers of toxicity or explosion. Two sensor platforms were investigated: Quartz crystal microbalances (QCM’s) and microcantilevers (MC’s). Preliminary evaluation of treated QCM’s, via frequency analyzer, showed improvements in sensitivity and fast reversal of adsorption; and suggested increased stability. Tests with coated MC’s also supported the findings of QCM tests. Amplitude response of MC’s was on average 4 times greater when the Nafion coating contained CNT’s. Quantitative QCM testing with gas-flow meters showed that with CNT inclusion: the average number of moles adsorbed increased by 35% (&gt;1.2 times frequency response); sensitivity improved by 0.63 Hz/ppt on average; although the detection threshold decreased marginally; but reusability was much better after extended exposures to concentrated ammonia.","abstract_has_math":false,"creators":["Davis, Charles"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:52:18Z","subjects":["Conducting polymers","Detectors -- Technological innovations","Explosives -- Detection","Nanocomposites (Materials)","Nanostructured materials","Smart materials"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_6/875","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_6/875","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_6-1874","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_6-1874","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Davis, Charles"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2013-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Conducting polymers","Detectors -- Technological innovations","Explosives -- Detection","Nanocomposites (Materials)","Nanostructured materials","Smart materials"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_6/875"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["With the goal of improving chemical detection methods for buried improvised explosive devices (IED’s), the intention of this study is to show that functionalized nano-particles improve the sensing properties of a polymer applied to gas sensors. The approach was reinforcing the polymer, Nafion, with acid-functionalized carbon nanotubes (CNT’s). Ammonia was chosen as the analyte for its similarity to IED byproducts without the dangers of toxicity or explosion. Two sensor platforms were investigated: Quartz crystal microbalances (QCM’s) and microcantilevers (MC’s). Preliminary evaluation of treated QCM’s, via frequency analyzer, showed improvements in sensitivity and fast reversal of adsorption; and suggested increased stability. Tests with coated MC’s also supported the findings of QCM tests. Amplitude response of MC’s was on average 4 times greater when the Nafion coating contained CNT’s. Quantitative QCM testing with gas-flow meters showed that with CNT inclusion: the average number of moles adsorbed increased by 35% (>1.2 times frequency response); sensitivity improved by 0.63 Hz/ppt on average; although the detection threshold decreased marginally; but reusability was much better after extended exposures to concentrated ammonia."]},{"key":"dc:description.note","label":"Dc Description Note","values":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2013.|Includes bibliography."]},{"key":"dc:title","label":"Title","values":["Studies of nanoparticle reinforced polymer coatings for trace gas detection"]}]}],"canonical_facts":{"dc:creator":["Davis, Charles"],"dc:date.created":["2013-01-01T08:00:00Z"],"dc:description.abstract":["With the goal of improving chemical detection methods for buried improvised explosive devices (IED’s), the intention of this study is to show that functionalized nano-particles improve the sensing properties of a polymer applied to gas sensors. The approach was reinforcing the polymer, Nafion, with acid-functionalized carbon nanotubes (CNT’s). Ammonia was chosen as the analyte for its similarity to IED byproducts without the dangers of toxicity or explosion. Two sensor platforms were investigated: Quartz crystal microbalances (QCM’s) and microcantilevers (MC’s). Preliminary evaluation of treated QCM’s, via frequency analyzer, showed improvements in sensitivity and fast reversal of adsorption; and suggested increased stability. Tests with coated MC’s also supported the findings of QCM tests. Amplitude response of MC’s was on average 4 times greater when the Nafion coating contained CNT’s. Quantitative QCM testing with gas-flow meters showed that with CNT inclusion: the average number of moles adsorbed increased by 35% (>1.2 times frequency response); sensitivity improved by 0.63 Hz/ppt on average; although the detection threshold decreased marginally; but reusability was much better after extended exposures to concentrated ammonia."],"dc:description.note":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2013.|Includes bibliography."],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_6/875"],"dc:subject":["Conducting polymers","Detectors -- Technological innovations","Explosives -- Detection","Nanocomposites (Materials)","Nanostructured materials","Smart materials"],"dc:title":["Studies of nanoparticle reinforced polymer coatings for trace gas detection"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:52:18Z"}