{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_6-2010"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_6-2010","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Fire resistance of corroded structural concrete","abstract":"One of the major causes of structural repairs worldwide is the corrosion of reinforced concrete structures, such as residential buildings and piers, which are exposed to harsh marine environments. This investigation aims to provide experimental evidence of the fire resistance of corroded high strength reinforced concrete. For this, 14 reinforced concrete beams of three different concrete mix designs (different strengths) were prepared along with concrete cylinders for compression strength testing (ASTM C39). After proper moist curing, all beams were corroded, in two phases, with impressed current, then “crack scored ”for corrosion evaluation, after which half were exposed to fire, also in two phases, following the ASTM E-119-12 time-temperature curve, using a gas kiln. The fire damage was evaluated and compared between phases by using Ultrasonic Pulse Velocity technology. Finally, all specimens were tested for flexural strength by using the third-point loading method (ASTM C78) and the effects of fire on the corroded beams were analyzed according to the level of corrosion.","abstract_html":"One of the major causes of structural repairs worldwide is the corrosion of reinforced concrete structures, such as residential buildings and piers, which are exposed to harsh marine environments. This investigation aims to provide experimental evidence of the fire resistance of corroded high strength reinforced concrete. For this, 14 reinforced concrete beams of three different concrete mix designs (different strengths) were prepared along with concrete cylinders for compression strength testing (ASTM C39). After proper moist curing, all beams were corroded, in two phases, with impressed current, then “crack scored ”for corrosion evaluation, after which half were exposed to fire, also in two phases, following the ASTM E-119-12 time-temperature curve, using a gas kiln. The fire damage was evaluated and compared between phases by using Ultrasonic Pulse Velocity technology. Finally, all specimens were tested for flexural strength by using the third-point loading method (ASTM C78) and the effects of fire on the corroded beams were analyzed according to the level of corrosion.","abstract_has_math":false,"creators":["Martinez, Fernando Jose"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:52:28Z","subjects":["Concrete -- Effect of temperature on","Fire resistant materials","Reinforced concrete -- Corrosion","Thermodynamics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_6/1011","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_6/1011","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_6-2010","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_6-2010","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Martinez, Fernando Jose"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2014-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Concrete -- Effect of temperature on","Fire resistant materials","Reinforced concrete -- Corrosion","Thermodynamics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_6/1011"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["One of the major causes of structural repairs worldwide is the corrosion of reinforced concrete structures, such as residential buildings and piers, which are exposed to harsh marine environments. This investigation aims to provide experimental evidence of the fire resistance of corroded high strength reinforced concrete. For this, 14 reinforced concrete beams of three different concrete mix designs (different strengths) were prepared along with concrete cylinders for compression strength testing (ASTM C39). After proper moist curing, all beams were corroded, in two phases, with impressed current, then “crack scored ”for corrosion evaluation, after which half were exposed to fire, also in two phases, following the ASTM E-119-12 time-temperature curve, using a gas kiln. The fire damage was evaluated and compared between phases by using Ultrasonic Pulse Velocity technology. Finally, all specimens were tested for flexural strength by using the third-point loading method (ASTM C78) and the effects of fire on the corroded beams were analyzed according to the level of corrosion."]},{"key":"dc:description.note","label":"Dc Description Note","values":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2014.|FAU Electronic Theses and Dissertations Collection|Includes bibliography."]},{"key":"dc:title","label":"Title","values":["Fire resistance of corroded structural concrete"]}]}],"canonical_facts":{"dc:creator":["Martinez, Fernando Jose"],"dc:date.created":["2014-01-01T08:00:00Z"],"dc:description.abstract":["One of the major causes of structural repairs worldwide is the corrosion of reinforced concrete structures, such as residential buildings and piers, which are exposed to harsh marine environments. This investigation aims to provide experimental evidence of the fire resistance of corroded high strength reinforced concrete. For this, 14 reinforced concrete beams of three different concrete mix designs (different strengths) were prepared along with concrete cylinders for compression strength testing (ASTM C39). After proper moist curing, all beams were corroded, in two phases, with impressed current, then “crack scored ”for corrosion evaluation, after which half were exposed to fire, also in two phases, following the ASTM E-119-12 time-temperature curve, using a gas kiln. The fire damage was evaluated and compared between phases by using Ultrasonic Pulse Velocity technology. Finally, all specimens were tested for flexural strength by using the third-point loading method (ASTM C78) and the effects of fire on the corroded beams were analyzed according to the level of corrosion."],"dc:description.note":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2014.|FAU Electronic Theses and Dissertations Collection|Includes bibliography."],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_6/1011"],"dc:subject":["Concrete -- Effect of temperature on","Fire resistant materials","Reinforced concrete -- Corrosion","Thermodynamics"],"dc:title":["Fire resistance of corroded structural concrete"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:52:28Z"}