{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_6-2444"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_6-2444","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Effect of Electronic Water Treatment System on Calcium Carbonate Scaling","abstract":"Calcium carbonate precipitation and formation of clog particles inside the leachate collection pipe can cause catastrophic failures in landfill operation. This study focuses on quantifying the effectiveness of electronic scale control to reduce the clog formation within the pipe network. A field scale model (40ft × 20ft) was constructed, featuring side-by-side flow of electronically treated and untreated composite leachate. Data obtained in the first phase of this study indicate that electronic scale control system does not have any statistically significant effect on water quality parameters. The second phase of this study identified calcite (CaCO3) to be the predominant phase present in the precipitates using XRD/XRF diffraction pattern analyzed through a search match calculation program (MATCH! Version 3.2.0) which concur with the previous studies. Furthermore, Rietveld refinement using FullProf Suite confirms that there were no differences between the treated and untreated precipitate based on the phases identified in the respective samples.","abstract_html":"Calcium carbonate precipitation and formation of clog particles inside the leachate collection pipe can cause catastrophic failures in landfill operation. This study focuses on quantifying the effectiveness of electronic scale control to reduce the clog formation within the pipe network. A field scale model (40ft × 20ft) was constructed, featuring side-by-side flow of electronically treated and untreated composite leachate. Data obtained in the first phase of this study indicate that electronic scale control system does not have any statistically significant effect on water quality parameters. The second phase of this study identified calcite (CaCO3) to be the predominant phase present in the precipitates using XRD/XRF diffraction pattern analyzed through a search match calculation program (MATCH! Version 3.2.0) which concur with the previous studies. Furthermore, Rietveld refinement using FullProf Suite confirms that there were no differences between the treated and untreated precipitate based on the phases identified in the respective samples.","abstract_has_math":false,"creators":["Shaha, Bishow Nath"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:52:48Z","subjects":["Calcium carbonate","Engineered barrier systems (Waste disposal)","Environmental engineering","Green technology","Incrustations","Materials science","Water -- Hardness","Water quality management"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_6/1445","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_6/1445","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_6-2444","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_6-2444","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Shaha, Bishow Nath"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2016-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Calcium carbonate","Engineered barrier systems (Waste disposal)","Environmental engineering","Green technology","Incrustations","Materials science","Water -- Hardness","Water quality management"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_6/1445"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Calcium carbonate precipitation and formation of clog particles inside the leachate collection pipe can cause catastrophic failures in landfill operation. This study focuses on quantifying the effectiveness of electronic scale control to reduce the clog formation within the pipe network. A field scale model (40ft × 20ft) was constructed, featuring side-by-side flow of electronically treated and untreated composite leachate. Data obtained in the first phase of this study indicate that electronic scale control system does not have any statistically significant effect on water quality parameters. The second phase of this study identified calcite (CaCO3) to be the predominant phase present in the precipitates using XRD/XRF diffraction pattern analyzed through a search match calculation program (MATCH! Version 3.2.0) which concur with the previous studies. Furthermore, Rietveld refinement using FullProf Suite confirms that there were no differences between the treated and untreated precipitate based on the phases identified in the respective samples."]},{"key":"dc:description.note","label":"Dc Description Note","values":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2016.|FAU Electronic Theses and Dissertations Collection|Includes bibliography."]},{"key":"dc:title","label":"Title","values":["Effect of Electronic Water Treatment System on Calcium Carbonate Scaling"]}]}],"canonical_facts":{"dc:creator":["Shaha, Bishow Nath"],"dc:date.created":["2016-01-01T08:00:00Z"],"dc:description.abstract":["Calcium carbonate precipitation and formation of clog particles inside the leachate collection pipe can cause catastrophic failures in landfill operation. This study focuses on quantifying the effectiveness of electronic scale control to reduce the clog formation within the pipe network. A field scale model (40ft × 20ft) was constructed, featuring side-by-side flow of electronically treated and untreated composite leachate. Data obtained in the first phase of this study indicate that electronic scale control system does not have any statistically significant effect on water quality parameters. The second phase of this study identified calcite (CaCO3) to be the predominant phase present in the precipitates using XRD/XRF diffraction pattern analyzed through a search match calculation program (MATCH! Version 3.2.0) which concur with the previous studies. Furthermore, Rietveld refinement using FullProf Suite confirms that there were no differences between the treated and untreated precipitate based on the phases identified in the respective samples."],"dc:description.note":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2016.|FAU Electronic Theses and Dissertations Collection|Includes bibliography."],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_6/1445"],"dc:subject":["Calcium carbonate","Engineered barrier systems (Waste disposal)","Environmental engineering","Green technology","Incrustations","Materials science","Water -- Hardness","Water quality management"],"dc:title":["Effect of Electronic Water Treatment System on Calcium Carbonate Scaling"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:52:48Z"}