{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_6-2676"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_6-2676","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Development of a Biosensor to Detect Landfill Odors Using Human Odorant Binding Protein","abstract":"Landfills receive odor complaints from local residents potentially resulting in legal ramifications and decreasing quality of life of the neighboring communities. However, analytical technologies to objectively measure odors in the field that will reflect human odor perceptions at a reasonable price do not currently exist. Hydrogen sulfide (H2S) is detectable by humans at low odor thresholds and may be one of the main nuisance odors emanating from landfills. For the first time, hOBPIIa complexed with 1- AMA has been used to detect H2S concentrations by spectrofluorometry. The optimal ratio of hOPBIIa-to-1-AMA was determined to be approximately 1:1. A strong linear regression model was generated to predict H2S concentrations from peak fluorescent emission intensity measurements within a range of 0-8.3 g of H2S. A novel experimental exposure chamber prototype was developed that has the potential to be incorporated into a portable sensor because it is compact.","abstract_html":"Landfills receive odor complaints from local residents potentially resulting in legal ramifications and decreasing quality of life of the neighboring communities. However, analytical technologies to objectively measure odors in the field that will reflect human odor perceptions at a reasonable price do not currently exist. Hydrogen sulfide (H2S) is detectable by humans at low odor thresholds and may be one of the main nuisance odors emanating from landfills. For the first time, hOBPIIa complexed with 1- AMA has been used to detect H2S concentrations by spectrofluorometry. The optimal ratio of hOPBIIa-to-1-AMA was determined to be approximately 1:1. A strong linear regression model was generated to predict H2S concentrations from peak fluorescent emission intensity measurements within a range of 0-8.3 g of H2S. A novel experimental exposure chamber prototype was developed that has the potential to be incorporated into a portable sensor because it is compact.","abstract_has_math":false,"creators":["Roblyer, Julia Gia"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:52:57Z","subjects":["Dissertations","Academic -- Florida Atlantic University","Landfills.","Biosensors.","Odor sensors.","Odor control."],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_6/1677","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_6/1677","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_6-2676","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_6-2676","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Roblyer, Julia Gia"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2017-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dissertations","Academic -- Florida Atlantic University","Landfills.","Biosensors.","Odor sensors.","Odor control."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_6/1677"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Landfills receive odor complaints from local residents potentially resulting in legal ramifications and decreasing quality of life of the neighboring communities. However, analytical technologies to objectively measure odors in the field that will reflect human odor perceptions at a reasonable price do not currently exist. Hydrogen sulfide (H2S) is detectable by humans at low odor thresholds and may be one of the main nuisance odors emanating from landfills. For the first time, hOBPIIa complexed with 1- AMA has been used to detect H2S concentrations by spectrofluorometry. The optimal ratio of hOPBIIa-to-1-AMA was determined to be approximately 1:1. A strong linear regression model was generated to predict H2S concentrations from peak fluorescent emission intensity measurements within a range of 0-8.3 g of H2S. A novel experimental exposure chamber prototype was developed that has the potential to be incorporated into a portable sensor because it is compact."]},{"key":"dc:description.note","label":"Dc Description Note","values":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2017.|FAU Electronic Theses and Dissertations Collection|Includes bibliography."]},{"key":"dc:title","label":"Title","values":["Development of a Biosensor to Detect Landfill Odors Using Human Odorant Binding Protein"]}]}],"canonical_facts":{"dc:creator":["Roblyer, Julia Gia"],"dc:date.created":["2017-01-01T08:00:00Z"],"dc:description.abstract":["Landfills receive odor complaints from local residents potentially resulting in legal ramifications and decreasing quality of life of the neighboring communities. However, analytical technologies to objectively measure odors in the field that will reflect human odor perceptions at a reasonable price do not currently exist. Hydrogen sulfide (H2S) is detectable by humans at low odor thresholds and may be one of the main nuisance odors emanating from landfills. For the first time, hOBPIIa complexed with 1- AMA has been used to detect H2S concentrations by spectrofluorometry. The optimal ratio of hOPBIIa-to-1-AMA was determined to be approximately 1:1. A strong linear regression model was generated to predict H2S concentrations from peak fluorescent emission intensity measurements within a range of 0-8.3 g of H2S. A novel experimental exposure chamber prototype was developed that has the potential to be incorporated into a portable sensor because it is compact."],"dc:description.note":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2017.|FAU Electronic Theses and Dissertations Collection|Includes bibliography."],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_6/1677"],"dc:subject":["Dissertations","Academic -- Florida Atlantic University","Landfills.","Biosensors.","Odor sensors.","Odor control."],"dc:title":["Development of a Biosensor to Detect Landfill Odors Using Human Odorant Binding Protein"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:52:57Z"}