{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_6-2899"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_6-2899","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Dosimetric and Radiobiological Comparison of the Effects of High Definition versus Normal Collimation on Treatment Plans for Stereotactic Lung Cancer Radiation Therapy","abstract":"Stereotactic Body Radiation Therapy (SBRT) is a modern precision radiation therapy to deliver the dose in 1 to 5 fractions with high target dose conformity, and steep dose gradient towards healthy tissues. The dose delivered is influenced by the leaf width of the MLC, especially in case of SBRT. Treatment plans with high definition (HD) MLC having leaf-width 2.5 mm and normal MLC having leaf-width 5 mm, were compared to quantify dosimetric and radiobiological parameters. Dosimetric parameters conformity indices (CI), gradient indices (GI) and heterogeneity indices (HI) were compared. The radiobiological parameters were evaluated by normal tissue complication probability (NTCP) and tumor control probability (TCP) based on the equivalent uniform dose (EUD). The results show that there is dosimetric and radiobiological merit of the HD MLC over the normal MLC. However, the improvement is not consistent with all the plans and thus further research is required prior to conclusion.","abstract_html":"Stereotactic Body Radiation Therapy (SBRT) is a modern precision radiation therapy to deliver the dose in 1 to 5 fractions with high target dose conformity, and steep dose gradient towards healthy tissues. The dose delivered is influenced by the leaf width of the MLC, especially in case of SBRT. Treatment plans with high definition (HD) MLC having leaf-width 2.5 mm and normal MLC having leaf-width 5 mm, were compared to quantify dosimetric and radiobiological parameters. Dosimetric parameters conformity indices (CI), gradient indices (GI) and heterogeneity indices (HI) were compared. The radiobiological parameters were evaluated by normal tissue complication probability (NTCP) and tumor control probability (TCP) based on the equivalent uniform dose (EUD). The results show that there is dosimetric and radiobiological merit of the HD MLC over the normal MLC. However, the improvement is not consistent with all the plans and thus further research is required prior to conclusion.","abstract_has_math":false,"creators":["Pudasaini, Mukunda Prasad"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:53:05Z","subjects":["Radiosurgery","Lung Neoplasms","Radiation dosimetry","Radiobiology"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_6/1900","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_6/1900","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_6-2899","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_6-2899","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Pudasaini, Mukunda Prasad"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2018-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Radiosurgery","Lung Neoplasms","Radiation dosimetry","Radiobiology"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_6/1900"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Stereotactic Body Radiation Therapy (SBRT) is a modern precision radiation therapy to deliver the dose in 1 to 5 fractions with high target dose conformity, and steep dose gradient towards healthy tissues. The dose delivered is influenced by the leaf width of the MLC, especially in case of SBRT. Treatment plans with high definition (HD) MLC having leaf-width 2.5 mm and normal MLC having leaf-width 5 mm, were compared to quantify dosimetric and radiobiological parameters. Dosimetric parameters conformity indices (CI), gradient indices (GI) and heterogeneity indices (HI) were compared. The radiobiological parameters were evaluated by normal tissue complication probability (NTCP) and tumor control probability (TCP) based on the equivalent uniform dose (EUD). The results show that there is dosimetric and radiobiological merit of the HD MLC over the normal MLC. However, the improvement is not consistent with all the plans and thus further research is required prior to conclusion."]},{"key":"dc:description.note","label":"Dc Description Note","values":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2018.|FAU Electronic Theses and Dissertations Collection|Includes bibliography."]},{"key":"dc:title","label":"Title","values":["Dosimetric and Radiobiological Comparison of the Effects of High Definition versus Normal Collimation on Treatment Plans for Stereotactic Lung Cancer Radiation Therapy"]}]}],"canonical_facts":{"dc:creator":["Pudasaini, Mukunda Prasad"],"dc:date.created":["2018-01-01T08:00:00Z"],"dc:description.abstract":["Stereotactic Body Radiation Therapy (SBRT) is a modern precision radiation therapy to deliver the dose in 1 to 5 fractions with high target dose conformity, and steep dose gradient towards healthy tissues. The dose delivered is influenced by the leaf width of the MLC, especially in case of SBRT. Treatment plans with high definition (HD) MLC having leaf-width 2.5 mm and normal MLC having leaf-width 5 mm, were compared to quantify dosimetric and radiobiological parameters. Dosimetric parameters conformity indices (CI), gradient indices (GI) and heterogeneity indices (HI) were compared. The radiobiological parameters were evaluated by normal tissue complication probability (NTCP) and tumor control probability (TCP) based on the equivalent uniform dose (EUD). The results show that there is dosimetric and radiobiological merit of the HD MLC over the normal MLC. However, the improvement is not consistent with all the plans and thus further research is required prior to conclusion."],"dc:description.note":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2018.|FAU Electronic Theses and Dissertations Collection|Includes bibliography."],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_6/1900"],"dc:subject":["Radiosurgery","Lung Neoplasms","Radiation dosimetry","Radiobiology"],"dc:title":["Dosimetric and Radiobiological Comparison of the Effects of High Definition versus Normal Collimation on Treatment Plans for Stereotactic Lung Cancer Radiation Therapy"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:53:05Z"}