{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_6-2957"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_6-2957","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"Investigation of Rotational Deviations on Single Fiducial Tumor Tracking with Simulated Respiratory Motion using Synchrony® Respiratory Motion Tracking for Cyberknife® Treatment","abstract":"It is hypothesized that the uncertainty of the Synchrony® model from the rotation of a geometrically asymmetrical single fiducial shall be non-zero during the motion tracking. To validate this hypothesis, the uncertainty was measured for a Synchrony® model built for a respiratory motion phantom oriented at different yaw angles on a Cyberknife® treatment table. A Mini-ball Cube with three cylindrical GoldMark™ (1mmx5mm Au) numbered fiducials was placed inside a respiratory phantom and used for all tests. The fiducial with the least artifact interference was selected for the motion tracking. A 2cm periodic, longitudinal, linear motion of the Mini-ball cube was executed and tested for yaw rotational angles, 0° – 90°. The test was repeated over 3 nonconsecutive days. The uncertainty increased with the yaw angle with the most noticeable changes seen between20° and 60° yaw, where uncertainty increased from 23.5% to 57.9%. A similar test was performed using a spherical Gold Anchor™ fiducial. The uncertainties found when using the Gold Anchor™ were statistically lower than those found when using the GoldMark™ fiducial for all angles of rotation. For the first time, it is found that Synchrony® model uncertainty depends on fiducial geometry. In addition, this research has shown that tracking target rotation using a single fiducial can be accomplished with the Synchrony® model uncertainty as it is displayed on the treatment console. The results of this research could lead to decreased acute toxicity effects related to multiple fiducials.","abstract_html":"It is hypothesized that the uncertainty of the Synchrony® model from the rotation of a geometrically asymmetrical single fiducial shall be non-zero during the motion tracking. To validate this hypothesis, the uncertainty was measured for a Synchrony® model built for a respiratory motion phantom oriented at different yaw angles on a Cyberknife® treatment table. A Mini-ball Cube with three cylindrical GoldMark™ (1mmx5mm Au) numbered fiducials was placed inside a respiratory phantom and used for all tests. The fiducial with the least artifact interference was selected for the motion tracking. A 2cm periodic, longitudinal, linear motion of the Mini-ball cube was executed and tested for yaw rotational angles, 0° – 90°. The test was repeated over 3 nonconsecutive days. The uncertainty increased with the yaw angle with the most noticeable changes seen between20° and 60° yaw, where uncertainty increased from 23.5% to 57.9%. A similar test was performed using a spherical Gold Anchor™ fiducial. The uncertainties found when using the Gold Anchor™ were statistically lower than those found when using the GoldMark™ fiducial for all angles of rotation. For the first time, it is found that Synchrony® model uncertainty depends on fiducial geometry. In addition, this research has shown that tracking target rotation using a single fiducial can be accomplished with the Synchrony® model uncertainty as it is displayed on the treatment console. The results of this research could lead to decreased acute toxicity effects related to multiple fiducials.","abstract_has_math":false,"creators":["Christ, Zachary A"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:53:09Z","subjects":["Fiducial Markers","Radiosurgery--Quality control","Robotic radiosurgery"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_6/1958","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_6/1958","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_6-2957","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_6-2957","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Christ, Zachary A"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2018-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fiducial Markers","Radiosurgery--Quality control","Robotic radiosurgery"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_6/1958"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["It is hypothesized that the uncertainty of the Synchrony® model from the rotation of a geometrically asymmetrical single fiducial shall be non-zero during the motion tracking. To validate this hypothesis, the uncertainty was measured for a Synchrony® model built for a respiratory motion phantom oriented at different yaw angles on a Cyberknife® treatment table. A Mini-ball Cube with three cylindrical GoldMark™ (1mmx5mm Au) numbered fiducials was placed inside a respiratory phantom and used for all tests. The fiducial with the least artifact interference was selected for the motion tracking. A 2cm periodic, longitudinal, linear motion of the Mini-ball cube was executed and tested for yaw rotational angles, 0° – 90°. The test was repeated over 3 nonconsecutive days. The uncertainty increased with the yaw angle with the most noticeable changes seen between20° and 60° yaw, where uncertainty increased from 23.5% to 57.9%. A similar test was performed using a spherical Gold Anchor™ fiducial. The uncertainties found when using the Gold Anchor™ were statistically lower than those found when using the GoldMark™ fiducial for all angles of rotation. For the first time, it is found that Synchrony® model uncertainty depends on fiducial geometry. In addition, this research has shown that tracking target rotation using a single fiducial can be accomplished with the Synchrony® model uncertainty as it is displayed on the treatment console. The results of this research could lead to decreased acute toxicity effects related to multiple fiducials."]},{"key":"dc:description.note","label":"Dc Description Note","values":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2018.|FAU Electronic Theses and Dissertations Collection|Includes bibliography."]},{"key":"dc:title","label":"Title","values":["Investigation of Rotational Deviations on Single Fiducial Tumor Tracking with Simulated Respiratory Motion using Synchrony® Respiratory Motion Tracking for Cyberknife® Treatment"]}]}],"canonical_facts":{"dc:creator":["Christ, Zachary A"],"dc:date.created":["2018-01-01T08:00:00Z"],"dc:description.abstract":["It is hypothesized that the uncertainty of the Synchrony® model from the rotation of a geometrically asymmetrical single fiducial shall be non-zero during the motion tracking. To validate this hypothesis, the uncertainty was measured for a Synchrony® model built for a respiratory motion phantom oriented at different yaw angles on a Cyberknife® treatment table. A Mini-ball Cube with three cylindrical GoldMark™ (1mmx5mm Au) numbered fiducials was placed inside a respiratory phantom and used for all tests. The fiducial with the least artifact interference was selected for the motion tracking. A 2cm periodic, longitudinal, linear motion of the Mini-ball cube was executed and tested for yaw rotational angles, 0° – 90°. The test was repeated over 3 nonconsecutive days. The uncertainty increased with the yaw angle with the most noticeable changes seen between20° and 60° yaw, where uncertainty increased from 23.5% to 57.9%. A similar test was performed using a spherical Gold Anchor™ fiducial. The uncertainties found when using the Gold Anchor™ were statistically lower than those found when using the GoldMark™ fiducial for all angles of rotation. For the first time, it is found that Synchrony® model uncertainty depends on fiducial geometry. In addition, this research has shown that tracking target rotation using a single fiducial can be accomplished with the Synchrony® model uncertainty as it is displayed on the treatment console. The results of this research could lead to decreased acute toxicity effects related to multiple fiducials."],"dc:description.note":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2018.|FAU Electronic Theses and Dissertations Collection|Includes bibliography."],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_6/1958"],"dc:subject":["Fiducial Markers","Radiosurgery--Quality control","Robotic radiosurgery"],"dc:title":["Investigation of Rotational Deviations on Single Fiducial Tumor Tracking with Simulated Respiratory Motion using Synchrony® Respiratory Motion Tracking for Cyberknife® Treatment"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:53:09Z"}