{"id":{"repo_id":"fau","oai_identifier":"oai:digitalcommons.fau.edu:etd_general_6-3270"},"canonical_url":"https://search.ndltd.org/etd/fau/oai:digitalcommons.fau.edu:etd_general_6-3270","repository":{"repo_id":"fau","name":"title=\"Search in OATD\">Florida Atlantic University","base_url":"https://digitalcommons.fau.edu/do/oai/"},"display":{"title":"SUPPORTED ERYTHROCYTE MEMBRANES ON PIEZOELECTRIC SENSORS FOR STUDYING THE INTERACTIONS BETWEEN NANOPARTICLES AND SURFACES OF RED BLOOD CELLS","abstract":"The Supported red blood cell membrane (SRBCm) was developed on a piezoelectric sensor to study the attachment of nanoparticles to erythrocyte surfaces. A well-dispersed colloidal suspension of fragments of RBCm was prepared from whole blood, and characterized thoroughly using cryogenic transmission electron microscopy, dynamic light scattering, and zeta potential analysis. To develop SRBCm, RBCm fragments were immobilized onthe sensor in a quartz crystal microbalance with dissipation monitoring system. A complete monolayer of flattened fragments of RBCm was formed on the positively charged surface of the piezoelectric sensor in 1 mM NaCl and 0.2 mM NaHCO3 at pH 7.1. The surface morphology of SRBCm was characterized via atomic force microscopy. The even distribution of surface proteins expressed on erythrocytes was found on SRBCm through indirect immunofluorescence microscopy. The attachment efficiencies of model nanoparticles, e.g. hematite nanoparticles and carboxylated polystyrene nanoparticles, on the SRBCm were quantified using a classic methodology. KEYWORDS: Supported erythrocyte membrane, piezoelectric sensor, phospholipid bilayers, nanoparticles","abstract_html":"The Supported red blood cell membrane (SRBCm) was developed on a piezoelectric sensor to study the attachment of nanoparticles to erythrocyte surfaces. A well-dispersed colloidal suspension of fragments of RBCm was prepared from whole blood, and characterized thoroughly using cryogenic transmission electron microscopy, dynamic light scattering, and zeta potential analysis. To develop SRBCm, RBCm fragments were immobilized onthe sensor in a quartz crystal microbalance with dissipation monitoring system. A complete monolayer of flattened fragments of RBCm was formed on the positively charged surface of the piezoelectric sensor in 1 mM NaCl and 0.2 mM NaHCO3 at pH 7.1. The surface morphology of SRBCm was characterized via atomic force microscopy. The even distribution of surface proteins expressed on erythrocytes was found on SRBCm through indirect immunofluorescence microscopy. The attachment efficiencies of model nanoparticles, e.g. hematite nanoparticles and carboxylated polystyrene nanoparticles, on the SRBCm were quantified using a classic methodology. KEYWORDS: Supported erythrocyte membrane, piezoelectric sensor, phospholipid bilayers, nanoparticles","abstract_has_math":false,"creators":["Islam, Tanaz"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:53:24Z","subjects":["Erythrocyte Membrane","Piezoelectric polymer biosensors","Nanoparticles","Phospholipid bilayers","Bilayer lipid membranes"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.fau.edu/etd_general_6/2271","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.fau.edu/etd_general_6/2271","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afau%3Aoai%3Adigitalcommons.fau.edu%3Aetd_general_6-3270","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.fau.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.fau.edu%3Aetd_general_6-3270","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Islam, Tanaz"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2019-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Erythrocyte Membrane","Piezoelectric polymer biosensors","Nanoparticles","Phospholipid bilayers","Bilayer lipid membranes"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.fau.edu/etd_general_6/2271"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Supported red blood cell membrane (SRBCm) was developed on a piezoelectric sensor to study the attachment of nanoparticles to erythrocyte surfaces. A well-dispersed colloidal suspension of fragments of RBCm was prepared from whole blood, and characterized thoroughly using cryogenic transmission electron microscopy, dynamic light scattering, and zeta potential analysis. To develop SRBCm, RBCm fragments were immobilized onthe sensor in a quartz crystal microbalance with dissipation monitoring system. A complete monolayer of flattened fragments of RBCm was formed on the positively charged surface of the piezoelectric sensor in 1 mM NaCl and 0.2 mM NaHCO3 at pH 7.1. The surface morphology of SRBCm was characterized via atomic force microscopy. The even distribution of surface proteins expressed on erythrocytes was found on SRBCm through indirect immunofluorescence microscopy. The attachment efficiencies of model nanoparticles, e.g. hematite nanoparticles and carboxylated polystyrene nanoparticles, on the SRBCm were quantified using a classic methodology. KEYWORDS: Supported erythrocyte membrane, piezoelectric sensor, phospholipid bilayers, nanoparticles"]},{"key":"dc:description.note","label":"Dc Description Note","values":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2019.|FAU Electronic Theses and Dissertations Collection|Includes bibliography."]},{"key":"dc:title","label":"Title","values":["SUPPORTED ERYTHROCYTE MEMBRANES ON PIEZOELECTRIC SENSORS FOR STUDYING THE INTERACTIONS BETWEEN NANOPARTICLES AND SURFACES OF RED BLOOD CELLS"]}]}],"canonical_facts":{"dc:creator":["Islam, Tanaz"],"dc:date.created":["2019-01-01T08:00:00Z"],"dc:description.abstract":["The Supported red blood cell membrane (SRBCm) was developed on a piezoelectric sensor to study the attachment of nanoparticles to erythrocyte surfaces. A well-dispersed colloidal suspension of fragments of RBCm was prepared from whole blood, and characterized thoroughly using cryogenic transmission electron microscopy, dynamic light scattering, and zeta potential analysis. To develop SRBCm, RBCm fragments were immobilized onthe sensor in a quartz crystal microbalance with dissipation monitoring system. A complete monolayer of flattened fragments of RBCm was formed on the positively charged surface of the piezoelectric sensor in 1 mM NaCl and 0.2 mM NaHCO3 at pH 7.1. The surface morphology of SRBCm was characterized via atomic force microscopy. The even distribution of surface proteins expressed on erythrocytes was found on SRBCm through indirect immunofluorescence microscopy. The attachment efficiencies of model nanoparticles, e.g. hematite nanoparticles and carboxylated polystyrene nanoparticles, on the SRBCm were quantified using a classic methodology. KEYWORDS: Supported erythrocyte membrane, piezoelectric sensor, phospholipid bilayers, nanoparticles"],"dc:description.note":["Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2019.|FAU Electronic Theses and Dissertations Collection|Includes bibliography."],"dc:identifier":["https://digitalcommons.fau.edu/etd_general_6/2271"],"dc:subject":["Erythrocyte Membrane","Piezoelectric polymer biosensors","Nanoparticles","Phospholipid bilayers","Bilayer lipid membranes"],"dc:title":["SUPPORTED ERYTHROCYTE MEMBRANES ON PIEZOELECTRIC SENSORS FOR STUDYING THE INTERACTIONS BETWEEN NANOPARTICLES AND SURFACES OF RED BLOOD CELLS"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-26T13:53:24Z"}