{"id":{"repo_id":"fu-berlin","oai_identifier":"oai:refubium.fu-berlin.de:fub188/37635"},"canonical_url":"https://search.ndltd.org/etd/fu-berlin/oai:refubium.fu-berlin.de:fub188/37635","repository":{"repo_id":"fu-berlin","name":"Freie Universität Berlin","base_url":"https://refubium.fu-berlin.de/oai/request"},"display":{"title":"T2-gewichtete MR-Tomographie fokaler Leberläsionen ohne und mit dem i.v. Kontrastmittel Resovist®: Vergleich einer schnellen mit einer hochaufgelösten Sequenz","abstract":"Purpose: Aim of the study was to evaluate the effect of an i.v. Injection of the iron-oxide based contrast medium (CM) Resovist® on liver lesions diagnostics efficiency for a fast T2-weighted single shot breathold TSE-sequence (T2w-HASTE) in comparsion to a high resolution T2-weighted TSE-sequence with prospective acquisition correction acquired during free breathing (T2w-PACE-TSE). Materials und Methods: A retrospective analysis of the MRI examinations of 42 pa-tients (18 men and 24 women between the ages of 28 and 77 years, mean 58.1 ± 13.5 years) with focal liver lesions acquired over a period of 16 months was performed. In all patients, the images were acquired before (native) and starting at 10 min after i.v. injection of a standard dose of Resovist® using the T2w-HASTE and T2w-PACE-TSE sequence. The four key parameters, i.e. overall image quality, liver-lesion contrast, artifacts and quality of fat saturation were qualitatively evaluated on a scale of 1–5. Two parameters were determined quantitatively: Liver-lesion contrast and the number of recognizable lesions depending on the lesion diameter (≤ 4 mm, 5-9 mm,> 9 mm). In addition, lesions were classified in cysts, metastases and solid tumors. A statistical evaluation was carried out for the qualitative variables using Cochran test and McNemar test. For the quantitative variables, an analysis of variance based on repeated measurements was used as a multiple method. The significance level was set at p <0.05. Results: Qualitative evaluation (=: not significant; <: significant): Overall image quality: T2w-HASTE native = T2w-HASTE CM < T2w-PACE-TSE = T2w-PACE-TSE CM; Liver-lesion contrast: T2w-HASTE native = T2w-HASTE CM < T2w-PACE-TSE native < T2w-PACE-TSE CM; Artifacts: Tendentially best rating for the T2w-PACE CM; quality of fat saturation: Only for T2w-PACE-TSE - homogeneous in 24/42, low inhomogeneity in 14/42, inadequate fat suppression in 4/42. Quantitative evaluation: liver-lesion contrast: T2w-HASTE native < T2w-HASTE CM = T2w-PACE-TSE native < T2w-PACE-TSE CM; number of detectable lesions ≤ 4 mm: T2w-HASTE native = T2w-HASTE-CM < T2w-PACE-TSE native = T2w-PACE-TSE CM; number of recognizable lesions 5 - 9 mm: T2w-HASTE native = T2w-HASTE CM < T2w-PACE-TSE native < T2w-PACE-TSE CM number of detectable lesions> 9 mm: T2w-HASTE native = T2w-HASTE CM < T2w-PACE-TSE native = T2w-PACE-TSE CM. Conclusion: The T2-weighted PACE-TSE is significantly superior to the T2-weighted HASTE in both in native and in the contrast-enhanced examination, with respect to image quality, recognizability of focal liver lesions and quantitative liver-lesion contrast. Thus, the additional time required for the T2-weighted PACE-TSE seems to be justified. In both sequences, the application of Resovist tends to increase slightly the number of detected lesions, this effect is however not significant.","abstract_html":"Purpose: Aim of the study was to evaluate the effect of an i.v. Injection of the iron-oxide based contrast medium (CM) Resovist® on liver lesions diagnostics efficiency for a fast T2-weighted single shot breathold TSE-sequence (T2w-HASTE) in comparsion to a high resolution T2-weighted TSE-sequence with prospective acquisition correction acquired during free breathing (T2w-PACE-TSE). Materials und Methods: A retrospective analysis of the MRI examinations of 42 pa-tients (18 men and 24 women between the ages of 28 and 77 years, mean 58.1 ± 13.5 years) with focal liver lesions acquired over a period of 16 months was performed. In all patients, the images were acquired before (native) and starting at 10 min after i.v. injection of a standard dose of Resovist® using the T2w-HASTE and T2w-PACE-TSE sequence. The four key parameters, i.e. overall image quality, liver-lesion contrast, artifacts and quality of fat saturation were qualitatively evaluated on a scale of 1–5. Two parameters were determined quantitatively: Liver-lesion contrast and the number of recognizable lesions depending on the lesion diameter (≤ 4 mm, 5-9 mm,&gt; 9 mm). In addition, lesions were classified in cysts, metastases and solid tumors. A statistical evaluation was carried out for the qualitative variables using Cochran test and McNemar test. For the quantitative variables, an analysis of variance based on repeated measurements was used as a multiple method. The significance level was set at p &lt;0.05. Results: Qualitative evaluation (=: not significant; &lt;: significant): Overall image quality: T2w-HASTE native = T2w-HASTE CM &lt; T2w-PACE-TSE = T2w-PACE-TSE CM; Liver-lesion contrast: T2w-HASTE native = T2w-HASTE CM &lt; T2w-PACE-TSE native &lt; T2w-PACE-TSE CM; Artifacts: Tendentially best rating for the T2w-PACE CM; quality of fat saturation: Only for T2w-PACE-TSE - homogeneous in 24/42, low inhomogeneity in 14/42, inadequate fat suppression in 4/42. Quantitative evaluation: liver-lesion contrast: T2w-HASTE native &lt; T2w-HASTE CM = T2w-PACE-TSE native &lt; T2w-PACE-TSE CM; number of detectable lesions ≤ 4 mm: T2w-HASTE native = T2w-HASTE-CM &lt; T2w-PACE-TSE native = T2w-PACE-TSE CM; number of recognizable lesions 5 - 9 mm: T2w-HASTE native = T2w-HASTE CM &lt; T2w-PACE-TSE native &lt; T2w-PACE-TSE CM number of detectable lesions&gt; 9 mm: T2w-HASTE native = T2w-HASTE CM &lt; T2w-PACE-TSE native = T2w-PACE-TSE CM. Conclusion: The T2-weighted PACE-TSE is significantly superior to the T2-weighted HASTE in both in native and in the contrast-enhanced examination, with respect to image quality, recognizability of focal liver lesions and quantitative liver-lesion contrast. Thus, the additional time required for the T2-weighted PACE-TSE seems to be justified. In both sequences, the application of Resovist tends to increase slightly the number of detected lesions, this effect is however not significant.","abstract_has_math":false,"creators":["Bresan, Viola"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Charité - Universitätsmedizin Berlin","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":["N.N."],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T03:50:19Z","subjects":["Liver imaging","MRT","Lesion detection","Respiratory triggering","SPIO"],"languages":["ger"],"rights":["open access"],"rights_urls":["http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen"],"identifier_entries":[{"key":"dc:identifier.urn","label":"URN","values":["urn:nbn:de:kobv:188-refubium-37635-8"],"render_values":[{"text":"urn:nbn:de:kobv:188-refubium-37635-8","href":"https://nbn-resolving.org/urn:nbn:de:kobv:188-refubium-37635-8","code":true}]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://refubium.fu-berlin.de/handle/fub188/37635"],"render_values":[{"text":"https://refubium.fu-berlin.de/handle/fub188/37635","href":"https://refubium.fu-berlin.de/handle/fub188/37635","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.17169/refubium-37350","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.17169/refubium-37350","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":"open","embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afu-berlin%3Aoai%3Arefubium.fu-berlin.de%3Afub188%2F37635","prefix":"oai_dc"},"source_record":{"url":"https://refubium.fu-berlin.de/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arefubium.fu-berlin.de%3Afub188%2F37635","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["N.N."]},{"key":"dc:contributor.department","label":"Department","values":["Charité - Universitätsmedizin Berlin"]},{"key":"dc:creator","label":"Author","values":["Bresan, Viola"]},{"key":"person:gender","label":"Person Gender","values":["female"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:type","label":"Dc Type","values":["doc-type:doctoralThesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Liver imaging","MRT","Lesion detection","Respiratory triggering","SPIO"]},{"key":"dc:subject.ddc","label":"Dc Subject Ddc","values":["ddc:610"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["ger"]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["open access"]},{"key":"dc:rights.proquest","label":"Dc Rights Proquest","values":["accept"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://refubium.fu-berlin.de/handle/fub188/37635","http://dx.doi.org/10.17169/refubium-37350"]},{"key":"dc:identifier.urn","label":"URN","values":["urn:nbn:de:kobv:188-refubium-37635-8"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Purpose: Aim of the study was to evaluate the effect of an i.v. Injection of the iron-oxide based contrast medium (CM) Resovist® on liver lesions diagnostics efficiency for a fast T2-weighted single shot breathold TSE-sequence (T2w-HASTE) in comparsion to a high resolution T2-weighted TSE-sequence with prospective acquisition correction acquired during free breathing (T2w-PACE-TSE). Materials und Methods: A retrospective analysis of the MRI examinations of 42 pa-tients (18 men and 24 women between the ages of 28 and 77 years, mean 58.1 ± 13.5 years) with focal liver lesions acquired over a period of 16 months was performed. In all patients, the images were acquired before (native) and starting at 10 min after i.v. injection of a standard dose of Resovist® using the T2w-HASTE and T2w-PACE-TSE sequence. The four key parameters, i.e. overall image quality, liver-lesion contrast, artifacts and quality of fat saturation were qualitatively evaluated on a scale of 1–5. Two parameters were determined quantitatively: Liver-lesion contrast and the number of recognizable lesions depending on the lesion diameter (≤ 4 mm, 5-9 mm,> 9 mm). In addition, lesions were classified in cysts, metastases and solid tumors. A statistical evaluation was carried out for the qualitative variables using Cochran test and McNemar test. For the quantitative variables, an analysis of variance based on repeated measurements was used as a multiple method. The significance level was set at p <0.05. Results: Qualitative evaluation (=: not significant; <: significant): Overall image quality: T2w-HASTE native = T2w-HASTE CM < T2w-PACE-TSE = T2w-PACE-TSE CM; Liver-lesion contrast: T2w-HASTE native = T2w-HASTE CM < T2w-PACE-TSE native < T2w-PACE-TSE CM; Artifacts: Tendentially best rating for the T2w-PACE CM; quality of fat saturation: Only for T2w-PACE-TSE - homogeneous in 24/42, low inhomogeneity in 14/42, inadequate fat suppression in 4/42. Quantitative evaluation: liver-lesion contrast: T2w-HASTE native < T2w-HASTE CM = T2w-PACE-TSE native < T2w-PACE-TSE CM; number of detectable lesions ≤ 4 mm: T2w-HASTE native = T2w-HASTE-CM < T2w-PACE-TSE native = T2w-PACE-TSE CM; number of recognizable lesions 5 - 9 mm: T2w-HASTE native = T2w-HASTE CM < T2w-PACE-TSE native < T2w-PACE-TSE CM number of detectable lesions> 9 mm: T2w-HASTE native = T2w-HASTE CM < T2w-PACE-TSE native = T2w-PACE-TSE CM. Conclusion: The T2-weighted PACE-TSE is significantly superior to the T2-weighted HASTE in both in native and in the contrast-enhanced examination, with respect to image quality, recognizability of focal liver lesions and quantitative liver-lesion contrast. Thus, the additional time required for the T2-weighted PACE-TSE seems to be justified. In both sequences, the application of Resovist tends to increase slightly the number of detected lesions, this effect is however not significant.","Ziel: Die vorliegende Studie hatte zum Ziel, für die Magnetresonanztomographie (MRT) der Leber zu untersuchen, wie sich die i.v. Injektion des Eisenoxid-Nanopartikel-basierten Kontrastmittels (KM) Resovist® auf die Darstellung fokaler Leberläsionen in einer schnellen T2w turbo Spinecho Sequenz (T2w-HASTE, während Atemstopp), und in einer T2w turbo Spinecho Sequenz mit Atemnavigation (T2w-PACE-TSE, während freier Atmung) auswirkt. Material und Methoden: Es wurden retrospektiv MRT-Untersuchungen von 42 Patienten (18 Männer und 24 Frauen im Alter zwischen 28 und 77 Jahren, im Mittel 58,1 ± 13,5 Jahre) mit fokalen Leberläsionen aus einem Zeitraum von 16 Monaten analysiert. Alle Patienten hatten Resovist® in einer Standarddosierung erhalten. Die Bildakquisition mit T2w-HASTE und T2w-PACE-TSE erfolgte vor sowie ab 10 min nach i.v. KM-Injektion. Es wurden qualitativ die vier Parameter Gesamtbildqualität, Leber-Läsions-Kontrast, Artefakte und Qualität der Fettsättigung auf einer Skala von 1–5 bewertet. Quantitativ wurden die zwei Parameter Leber-Läsions-Kontrast anhand von region-of-interest-basierten Messungen und Anzahl erkennbarer Läsionen in Abhängigkeit des Läsionsdurchmessers bestimmt (≤ 4 mm,5 – 9 mm, > 9 mm). Zusätzlich erfolgte eine Einteilung nach Zysten, Metastasen oder soliden Tumoren. Die statistische Auswer-tung wurde für die qualitativen Variablen mit dem Cochran-Test und mit dem McNe-mar- Test durchgeführt. Für die quantitativen Variablen wurde die Varianzanalyse für Messwiederholungen als multiples Verfahren verwendet. Signifikanz wurde für p < 0,05 festgelegt. Ergebnisse: Qualitative Auswertung (=: nicht signifikant; <: signifikant): Gesamtbildqualität: T2w-HASTE nativ = T2w-HASTE KM < T2w-PACE-TSE nativ = T2w-PACE-TSE KM; Leber-Läsions-Kontrast: T2w-HASTE nativ = T2w-HASTE KM < T2w-PACE-TSE nativ < T2w-PACE-TSE KM; Artefakte: Tendenziell beste Bewertung für die T2w-PACE KM; Qualität der Fettsättigung: Nur für T2w-PACE-TSE – bei 24/42 homogen, bei 14/42 geringe Inhomogenität, bei 4/42 unzureichende Fettsuppression. Quantitative Auswertung: Leber-Läsions-Kontrast: T2w-HASTE nativ < T2w-HASTE KM = T2w-PACE-TSE nativ < T2w-PACE-TSE KM; Anzahl erkennbarer Läsionen ≤ 4 mm: T2w-HASTE nativ = T2w-HASTE-KM < T2w-PACE-TSE nativ = T2w-PACE-TSE KM; Anzahl erkennbarer Läsionen 5 – 9 mm: T2w-HASTE nativ = T2w-HASTE KM < T2w-PACE-TSE nativ < T2w-PACE-TSE KM; Anzahl erkennbarer Läsionen > 9 mm: T2w-HASTE nativ = T2w-HASTE KM < T2w-PACE-TSE nativ = T2w-PACE-TSE KM. Schlussfolgerung: Die T2w-PACE-TSE ist der T2w-HASTE in der nativen und KM-unterstützen Untersuchung bezüglich Bildqualität, Erkennbarkeit fokaler Leberläsionen und quantitativem Leber-Läsions-Kontrast signifikant überlegen, sodass der zeitliche Mehraufwand für die T2w-PACE TSE gerechtfertigt erscheint. In beiden Sequenzen führt die Injektion von Resovist zu einer tendenziellen, jedoch nicht signifikanten Erhöhung der Anzahl der erkannten Läsionen."]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["free"]},{"key":"dc:title","label":"Title","values":["T2-gewichtete MR-Tomographie fokaler Leberläsionen ohne und mit dem i.v. Kontrastmittel Resovist®: Vergleich einer schnellen mit einer hochaufgelösten Sequenz"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["T2-weighted MR-Imaging of Focal Liver Lesions without and with the i.v. Contrast Agent Resovist®: Comparison of a Fast with a High-Resolution Sequence"]}]}],"canonical_facts":{"dc:contributor.committeemember":["N.N."],"dc:contributor.department":["Charité - Universitätsmedizin Berlin"],"dc:creator":["Bresan, Viola"],"dc:date.issued":["2023"],"dc:description.abstract":["Purpose: Aim of the study was to evaluate the effect of an i.v. Injection of the iron-oxide based contrast medium (CM) Resovist® on liver lesions diagnostics efficiency for a fast T2-weighted single shot breathold TSE-sequence (T2w-HASTE) in comparsion to a high resolution T2-weighted TSE-sequence with prospective acquisition correction acquired during free breathing (T2w-PACE-TSE). Materials und Methods: A retrospective analysis of the MRI examinations of 42 pa-tients (18 men and 24 women between the ages of 28 and 77 years, mean 58.1 ± 13.5 years) with focal liver lesions acquired over a period of 16 months was performed. In all patients, the images were acquired before (native) and starting at 10 min after i.v. injection of a standard dose of Resovist® using the T2w-HASTE and T2w-PACE-TSE sequence. The four key parameters, i.e. overall image quality, liver-lesion contrast, artifacts and quality of fat saturation were qualitatively evaluated on a scale of 1–5. Two parameters were determined quantitatively: Liver-lesion contrast and the number of recognizable lesions depending on the lesion diameter (≤ 4 mm, 5-9 mm,> 9 mm). In addition, lesions were classified in cysts, metastases and solid tumors. A statistical evaluation was carried out for the qualitative variables using Cochran test and McNemar test. For the quantitative variables, an analysis of variance based on repeated measurements was used as a multiple method. The significance level was set at p <0.05. Results: Qualitative evaluation (=: not significant; <: significant): Overall image quality: T2w-HASTE native = T2w-HASTE CM < T2w-PACE-TSE = T2w-PACE-TSE CM; Liver-lesion contrast: T2w-HASTE native = T2w-HASTE CM < T2w-PACE-TSE native < T2w-PACE-TSE CM; Artifacts: Tendentially best rating for the T2w-PACE CM; quality of fat saturation: Only for T2w-PACE-TSE - homogeneous in 24/42, low inhomogeneity in 14/42, inadequate fat suppression in 4/42. Quantitative evaluation: liver-lesion contrast: T2w-HASTE native < T2w-HASTE CM = T2w-PACE-TSE native < T2w-PACE-TSE CM; number of detectable lesions ≤ 4 mm: T2w-HASTE native = T2w-HASTE-CM < T2w-PACE-TSE native = T2w-PACE-TSE CM; number of recognizable lesions 5 - 9 mm: T2w-HASTE native = T2w-HASTE CM < T2w-PACE-TSE native < T2w-PACE-TSE CM number of detectable lesions> 9 mm: T2w-HASTE native = T2w-HASTE CM < T2w-PACE-TSE native = T2w-PACE-TSE CM. Conclusion: The T2-weighted PACE-TSE is significantly superior to the T2-weighted HASTE in both in native and in the contrast-enhanced examination, with respect to image quality, recognizability of focal liver lesions and quantitative liver-lesion contrast. Thus, the additional time required for the T2-weighted PACE-TSE seems to be justified. In both sequences, the application of Resovist tends to increase slightly the number of detected lesions, this effect is however not significant.","Ziel: Die vorliegende Studie hatte zum Ziel, für die Magnetresonanztomographie (MRT) der Leber zu untersuchen, wie sich die i.v. Injektion des Eisenoxid-Nanopartikel-basierten Kontrastmittels (KM) Resovist® auf die Darstellung fokaler Leberläsionen in einer schnellen T2w turbo Spinecho Sequenz (T2w-HASTE, während Atemstopp), und in einer T2w turbo Spinecho Sequenz mit Atemnavigation (T2w-PACE-TSE, während freier Atmung) auswirkt. Material und Methoden: Es wurden retrospektiv MRT-Untersuchungen von 42 Patienten (18 Männer und 24 Frauen im Alter zwischen 28 und 77 Jahren, im Mittel 58,1 ± 13,5 Jahre) mit fokalen Leberläsionen aus einem Zeitraum von 16 Monaten analysiert. Alle Patienten hatten Resovist® in einer Standarddosierung erhalten. Die Bildakquisition mit T2w-HASTE und T2w-PACE-TSE erfolgte vor sowie ab 10 min nach i.v. KM-Injektion. Es wurden qualitativ die vier Parameter Gesamtbildqualität, Leber-Läsions-Kontrast, Artefakte und Qualität der Fettsättigung auf einer Skala von 1–5 bewertet. Quantitativ wurden die zwei Parameter Leber-Läsions-Kontrast anhand von region-of-interest-basierten Messungen und Anzahl erkennbarer Läsionen in Abhängigkeit des Läsionsdurchmessers bestimmt (≤ 4 mm,5 – 9 mm, > 9 mm). Zusätzlich erfolgte eine Einteilung nach Zysten, Metastasen oder soliden Tumoren. Die statistische Auswer-tung wurde für die qualitativen Variablen mit dem Cochran-Test und mit dem McNe-mar- Test durchgeführt. Für die quantitativen Variablen wurde die Varianzanalyse für Messwiederholungen als multiples Verfahren verwendet. Signifikanz wurde für p < 0,05 festgelegt. Ergebnisse: Qualitative Auswertung (=: nicht signifikant; <: signifikant): Gesamtbildqualität: T2w-HASTE nativ = T2w-HASTE KM < T2w-PACE-TSE nativ = T2w-PACE-TSE KM; Leber-Läsions-Kontrast: T2w-HASTE nativ = T2w-HASTE KM < T2w-PACE-TSE nativ < T2w-PACE-TSE KM; Artefakte: Tendenziell beste Bewertung für die T2w-PACE KM; Qualität der Fettsättigung: Nur für T2w-PACE-TSE – bei 24/42 homogen, bei 14/42 geringe Inhomogenität, bei 4/42 unzureichende Fettsuppression. Quantitative Auswertung: Leber-Läsions-Kontrast: T2w-HASTE nativ < T2w-HASTE KM = T2w-PACE-TSE nativ < T2w-PACE-TSE KM; Anzahl erkennbarer Läsionen ≤ 4 mm: T2w-HASTE nativ = T2w-HASTE-KM < T2w-PACE-TSE nativ = T2w-PACE-TSE KM; Anzahl erkennbarer Läsionen 5 – 9 mm: T2w-HASTE nativ = T2w-HASTE KM < T2w-PACE-TSE nativ < T2w-PACE-TSE KM; Anzahl erkennbarer Läsionen > 9 mm: T2w-HASTE nativ = T2w-HASTE KM < T2w-PACE-TSE nativ = T2w-PACE-TSE KM. Schlussfolgerung: Die T2w-PACE-TSE ist der T2w-HASTE in der nativen und KM-unterstützen Untersuchung bezüglich Bildqualität, Erkennbarkeit fokaler Leberläsionen und quantitativem Leber-Läsions-Kontrast signifikant überlegen, sodass der zeitliche Mehraufwand für die T2w-PACE TSE gerechtfertigt erscheint. In beiden Sequenzen führt die Injektion von Resovist zu einer tendenziellen, jedoch nicht signifikanten Erhöhung der Anzahl der erkannten Läsionen."],"dc:identifier.uri":["https://refubium.fu-berlin.de/handle/fub188/37635","http://dx.doi.org/10.17169/refubium-37350"],"dc:identifier.urn":["urn:nbn:de:kobv:188-refubium-37635-8"],"dc:language":["ger"],"dc:rights.accessrights":["open access"],"dc:rights.proquest":["accept"],"dc:rights.uri":["http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen"],"dc:subject":["Liver imaging","MRT","Lesion detection","Respiratory triggering","SPIO"],"dc:subject.ddc":["ddc:610"],"dcterms:accessrights":["free"],"dc:title":["T2-gewichtete MR-Tomographie fokaler Leberläsionen ohne und mit dem i.v. Kontrastmittel Resovist®: Vergleich einer schnellen mit einer hochaufgelösten Sequenz"],"dc:title.alternative":["T2-weighted MR-Imaging of Focal Liver Lesions without and with the i.v. Contrast Agent Resovist®: Comparison of a Fast with a High-Resolution Sequence"],"dc:type":["doc-type:doctoralThesis"],"dc:type.dcmitype":["Text"],"person:gender":["female"]},"updated_at":"2026-11-19T03:50:19Z"}