{"id":{"repo_id":"fu-berlin","oai_identifier":"oai:refubium.fu-berlin.de:fub188/51646"},"canonical_url":"https://search.ndltd.org/etd/fu-berlin/oai:refubium.fu-berlin.de:fub188/51646","repository":{"repo_id":"fu-berlin","name":"Freie Universität Berlin","base_url":"https://refubium.fu-berlin.de/oai/request"},"display":{"title":"RF Heating Effects and NMR-Based Thermometry with Hyperpolarized Xenon for Optimized CEST MRI","abstract":"With the approval of hyperpolarized 129Xe as a clinical MRI agent for lung imaging, ad-ditional applications of 129Xe with saturation transfer NMR in other fields such as NMR thermometry and molecular imaging have gained interest. Pulsed-shaped saturation for HyperCEST molecular imaging has been introduced earlier but under unsuitable conditions, making it hard to identify a true benefit in shaped RF pulses and to com-pare associated heating effects. This motivates the investigation of 129Xe NMR but also requires thermometry calibration and quantification of RF heating effects. In one part of this thesis, temperature-induced shifts for signals of caged Xe are studied for the first time in more detail. In another one, the effects of RF heating in HyperCEST NMR are investigated in a systematic comparison of RF responses using two types of 129Xe hosts while exploring options for optimization of the saturation scheme. The heating effect sensed by 129Xe was analyzed in water and dPBS with different RF power, duty cycle, saturation time, and pulse shape. Two 129Xe hosts, cryptophane-A monoacid (CrA-ma) and cucurbit-6-uril (CB[6]), with moderate and fast exchange rates, were studied in z-spectra for 5 to 20 seconds of pulsed saturation. The pulse power was in the range of 13 µT to 58 µT. Analysis was done by fitting exponential Lorentzi-ans to the z-spectra. No heating difference was observed for applying 10 sec of saturation or 1 sec of satu-ration for 10 loops. As expected, the solvent type affects the heating, as it was observed 55% more heating in a saline solution compared to pure water under otherwise same conditions. Considering the average power equivalent, a 100 mW (31 µT) block pulse (BP) requires comparison with a 286 mW (51 µT) dSNOB and a 343 mW (57 µT) Gauss pulse. The power equivalent-adjusted pulses show identical heating for BP, dSNOB, and Gauss-shaped pulses. Xe exchanging with CB[6] clearly benefits from stronger saturation whereas the CrA-ma response does not improve. The signals of the two hosts have better temperature sensitivity compared to the PRF method as the CrA-ma signal shifts by 0.26ppm/°C and the CB[6] signal shifts by 0.09ppm/°C. Saturation with shaped pulses does not bring an apparent benefit compared to BP sat-uration when comparing for the same duration and effective B1. Previous studies only demonstrated that stronger or longer pulses will obviously have better performance. The overall width of the CEST responses is dominated by the exchange kinetics and is almost independent of the pulse shape for the conditions tested here. Only at high powers, the dSNOB pulse might be slightly more selective than the BP.","abstract_html":"With the approval of hyperpolarized 129Xe as a clinical MRI agent for lung imaging, ad-ditional applications of 129Xe with saturation transfer NMR in other fields such as NMR thermometry and molecular imaging have gained interest. Pulsed-shaped saturation for HyperCEST molecular imaging has been introduced earlier but under unsuitable conditions, making it hard to identify a true benefit in shaped RF pulses and to com-pare associated heating effects. This motivates the investigation of 129Xe NMR but also requires thermometry calibration and quantification of RF heating effects. In one part of this thesis, temperature-induced shifts for signals of caged Xe are studied for the first time in more detail. In another one, the effects of RF heating in HyperCEST NMR are investigated in a systematic comparison of RF responses using two types of 129Xe hosts while exploring options for optimization of the saturation scheme. The heating effect sensed by 129Xe was analyzed in water and dPBS with different RF power, duty cycle, saturation time, and pulse shape. Two 129Xe hosts, cryptophane-A monoacid (CrA-ma) and cucurbit-6-uril (CB[6]), with moderate and fast exchange rates, were studied in z-spectra for 5 to 20 seconds of pulsed saturation. The pulse power was in the range of 13 µT to 58 µT. Analysis was done by fitting exponential Lorentzi-ans to the z-spectra. No heating difference was observed for applying 10 sec of saturation or 1 sec of satu-ration for 10 loops. As expected, the solvent type affects the heating, as it was observed 55% more heating in a saline solution compared to pure water under otherwise same conditions. Considering the average power equivalent, a 100 mW (31 µT) block pulse (BP) requires comparison with a 286 mW (51 µT) dSNOB and a 343 mW (57 µT) Gauss pulse. The power equivalent-adjusted pulses show identical heating for BP, dSNOB, and Gauss-shaped pulses. Xe exchanging with CB[6] clearly benefits from stronger saturation whereas the CrA-ma response does not improve. The signals of the two hosts have better temperature sensitivity compared to the PRF method as the CrA-ma signal shifts by 0.26ppm/°C and the CB[6] signal shifts by 0.09ppm/°C. Saturation with shaped pulses does not bring an apparent benefit compared to BP sat-uration when comparing for the same duration and effective B1. Previous studies only demonstrated that stronger or longer pulses will obviously have better performance. The overall width of the CEST responses is dominated by the exchange kinetics and is almost independent of the pulse shape for the conditions tested here. Only at high powers, the dSNOB pulse might be slightly more selective than the BP.","abstract_has_math":false,"creators":["Hernandez Solarte, David Antonio"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Charité - Universitätsmedizin Berlin","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":["N.N."],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T03:53:47Z","subjects":["CEST","Hyperpolarized Xenon","RF Heating"],"languages":["eng"],"rights":["open access"],"rights_urls":["http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen"],"identifier_entries":[{"key":"dc:identifier.urn","label":"URN","values":["urn:nbn:de:kobv:188-refubium-51646-6"],"render_values":[{"text":"urn:nbn:de:kobv:188-refubium-51646-6","href":"https://nbn-resolving.org/urn:nbn:de:kobv:188-refubium-51646-6","code":true}]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://refubium.fu-berlin.de/handle/fub188/51646"],"render_values":[{"text":"https://refubium.fu-berlin.de/handle/fub188/51646","href":"https://refubium.fu-berlin.de/handle/fub188/51646","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.17169/refubium-51374","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.17169/refubium-51374","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":"open","embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afu-berlin%3Aoai%3Arefubium.fu-berlin.de%3Afub188%2F51646","prefix":"oai_dc"},"source_record":{"url":"https://refubium.fu-berlin.de/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arefubium.fu-berlin.de%3Afub188%2F51646","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["N.N."]},{"key":"dc:contributor.department","label":"Department","values":["Charité - Universitätsmedizin Berlin"]},{"key":"dc:creator","label":"Author","values":["Hernandez Solarte, David Antonio"]},{"key":"person:gender","label":"Person Gender","values":["male"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:relation.issupplementedby","label":"Dc Relation Issupplementedby","values":["doi.org/10.1002/cphc.202401037"]},{"key":"dc:type","label":"Dc Type","values":["doc-type:doctoralThesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["CEST","Hyperpolarized Xenon","RF Heating"]},{"key":"dc:subject.ddc","label":"Dc Subject Ddc","values":["ddc:610"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["open access"]},{"key":"dc:rights.proquest","label":"Dc Rights Proquest","values":["accept"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://refubium.fu-berlin.de/handle/fub188/51646","http://dx.doi.org/10.17169/refubium-51374"]},{"key":"dc:identifier.urn","label":"URN","values":["urn:nbn:de:kobv:188-refubium-51646-6"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["With the approval of hyperpolarized 129Xe as a clinical MRI agent for lung imaging, ad-ditional applications of 129Xe with saturation transfer NMR in other fields such as NMR thermometry and molecular imaging have gained interest. Pulsed-shaped saturation for HyperCEST molecular imaging has been introduced earlier but under unsuitable conditions, making it hard to identify a true benefit in shaped RF pulses and to com-pare associated heating effects. This motivates the investigation of 129Xe NMR but also requires thermometry calibration and quantification of RF heating effects. In one part of this thesis, temperature-induced shifts for signals of caged Xe are studied for the first time in more detail. In another one, the effects of RF heating in HyperCEST NMR are investigated in a systematic comparison of RF responses using two types of 129Xe hosts while exploring options for optimization of the saturation scheme. The heating effect sensed by 129Xe was analyzed in water and dPBS with different RF power, duty cycle, saturation time, and pulse shape. Two 129Xe hosts, cryptophane-A monoacid (CrA-ma) and cucurbit-6-uril (CB[6]), with moderate and fast exchange rates, were studied in z-spectra for 5 to 20 seconds of pulsed saturation. The pulse power was in the range of 13 µT to 58 µT. Analysis was done by fitting exponential Lorentzi-ans to the z-spectra. No heating difference was observed for applying 10 sec of saturation or 1 sec of satu-ration for 10 loops. As expected, the solvent type affects the heating, as it was observed 55% more heating in a saline solution compared to pure water under otherwise same conditions. Considering the average power equivalent, a 100 mW (31 µT) block pulse (BP) requires comparison with a 286 mW (51 µT) dSNOB and a 343 mW (57 µT) Gauss pulse. The power equivalent-adjusted pulses show identical heating for BP, dSNOB, and Gauss-shaped pulses. Xe exchanging with CB[6] clearly benefits from stronger saturation whereas the CrA-ma response does not improve. The signals of the two hosts have better temperature sensitivity compared to the PRF method as the CrA-ma signal shifts by 0.26ppm/°C and the CB[6] signal shifts by 0.09ppm/°C. Saturation with shaped pulses does not bring an apparent benefit compared to BP sat-uration when comparing for the same duration and effective B1. Previous studies only demonstrated that stronger or longer pulses will obviously have better performance. The overall width of the CEST responses is dominated by the exchange kinetics and is almost independent of the pulse shape for the conditions tested here. Only at high powers, the dSNOB pulse might be slightly more selective than the BP.","Mit der Zulassung von hyperpolarisiertem 129Xe als MRT-Kontrastmittel zur Lungenbildgebung haben Anwendungen von 129Xe mit Sättigungstransfer-NMR in Bereichen wie NMR-Thermometrie und molekularer Bildgebung an Interesse gewonnen. Die gepulste Sättigung für die molekulare HyperCEST-Bildgebung wurde in der Vergangenheit bereits untersucht, allerdings ohne dass sinnvolle Aussagen über die möglichen Vorteile von selektiven HF-Pulsen möglich waren oder die damit verbundenen Erwärmungseffekte vermessen wurden. Dies motiviert neue Untersuchungen mit 129Xe-NMR und erfordert eine Kalibrierung der Thermometrie und eine Quantifizierung der HF-Erwärmung. Zum einen wurden hier die temperaturbedingten Verschiebungen für Signale von Xe in molekularen Käfigen zum ersten Mal genauer untersucht. Zum anderen quantifiziert diese Arbeit die Auswirkungen der HF-Erwärmung in der HyperCEST-NMR, indem ein systematischer Vergleich der Signal-Antworten mit zwei Arten von 129Xe-Wirten durchgeführt wurde, während die Erwärmung gemessen und eine Optimierung des Sättigungsschemas untersucht wurde. Der mittels 129Xe gemssene Erwärmungseffekt wurde in Wasser und dPBS mit unterschiedlicher HF-Leistung, Duty Cycle, Sättigungszeit und Pulsform analysiert. Zwei 129Xe-Wirte, Cryptophan-A-Monosäure (CrA-ma) und Cucurbit-[6]-uril (CB[6]) mit mäßigen bzw. schnellen Austauschraten, wurden für 5 bis 20 s gepulster Sättigung untersucht wobei die Pulsstärke im Bereich von 13 bis 58 µT lag. Die Analyse erfolgte durch Anpassung exponentieller Lorentz-Linien an die z-Spektren. Es wurde kein Unterschied in der Erwärmung zwischen 10 s Sättigung oder 1 s Sättigung mit 10 Wiederholungen festgestellt. Wie erwartet, wirkt sich die Art des Lösungsmittels auf die Erwärmung aus: die Erwärmung in einer Kochsalzlösung im Vergleich zu reinem Wasser ist unter ansonsten gleichen Bedingungen 55% höher. Betrachtet man das Leistungsäquivalent, muss ein 100 mW (31 µT) Blockpuls (BP) mit einem 286 mW (51 µT) dSNOB und einem 343 mW (57 µT) Gauß-Puls verglichen werden. Die leistungsäquivalent-bereinigten Pulse zeigen eine identische Erwärmung für alle drei Pulse. Xe, das in CB[6] austauscht, profitiert eindeutig von einer stärkeren Sättigung, während sich die Antwort von CrA-ma nicht verbessert. Die Signale der beiden Wirte sind im Vergleich zu PRF-Methode empfindlicher, denn das CrA-ma-Signal verschiebt sich um 0,26ppm/°C und das CB[6]-Signal um 0,09ppm/°C. Die Sättigung mit geformten Impulsen bringt im Vergleich zur BP-Sättigung keinen offensichtlichen Vorteil, wenn man die gleiche Dauer und das gleiche effektive B1 vergleicht. Frühere Studien haben lediglich gezeigt, dass stärkere oder längere Pulse offensichtlich eine bessere Leistung erbringen. Die Breite der CEST-Antworten wird von der Austauschkinetik dominiert und ist unter den hier getesteten Bedingungen weitgehend unabhängig von der Pulsform. Nur bei hohen Leistungen könnte der dSNOB-Puls etwas selektiver sein als der BP."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["112"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["free"]},{"key":"dc:title","label":"Title","values":["RF Heating Effects and NMR-Based Thermometry with Hyperpolarized Xenon for Optimized CEST MRI"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["RF-Aufheizungen und NMR-basierte Thermometrie mit hyperpolarisiertem Xenon für Optimierte CEST-MRI"]}]}],"canonical_facts":{"dc:contributor.committeemember":["N.N."],"dc:contributor.department":["Charité - Universitätsmedizin Berlin"],"dc:creator":["Hernandez Solarte, David Antonio"],"dc:date.issued":["2026"],"dc:description.abstract":["With the approval of hyperpolarized 129Xe as a clinical MRI agent for lung imaging, ad-ditional applications of 129Xe with saturation transfer NMR in other fields such as NMR thermometry and molecular imaging have gained interest. Pulsed-shaped saturation for HyperCEST molecular imaging has been introduced earlier but under unsuitable conditions, making it hard to identify a true benefit in shaped RF pulses and to com-pare associated heating effects. This motivates the investigation of 129Xe NMR but also requires thermometry calibration and quantification of RF heating effects. In one part of this thesis, temperature-induced shifts for signals of caged Xe are studied for the first time in more detail. In another one, the effects of RF heating in HyperCEST NMR are investigated in a systematic comparison of RF responses using two types of 129Xe hosts while exploring options for optimization of the saturation scheme. The heating effect sensed by 129Xe was analyzed in water and dPBS with different RF power, duty cycle, saturation time, and pulse shape. Two 129Xe hosts, cryptophane-A monoacid (CrA-ma) and cucurbit-6-uril (CB[6]), with moderate and fast exchange rates, were studied in z-spectra for 5 to 20 seconds of pulsed saturation. The pulse power was in the range of 13 µT to 58 µT. Analysis was done by fitting exponential Lorentzi-ans to the z-spectra. No heating difference was observed for applying 10 sec of saturation or 1 sec of satu-ration for 10 loops. As expected, the solvent type affects the heating, as it was observed 55% more heating in a saline solution compared to pure water under otherwise same conditions. Considering the average power equivalent, a 100 mW (31 µT) block pulse (BP) requires comparison with a 286 mW (51 µT) dSNOB and a 343 mW (57 µT) Gauss pulse. The power equivalent-adjusted pulses show identical heating for BP, dSNOB, and Gauss-shaped pulses. Xe exchanging with CB[6] clearly benefits from stronger saturation whereas the CrA-ma response does not improve. The signals of the two hosts have better temperature sensitivity compared to the PRF method as the CrA-ma signal shifts by 0.26ppm/°C and the CB[6] signal shifts by 0.09ppm/°C. Saturation with shaped pulses does not bring an apparent benefit compared to BP sat-uration when comparing for the same duration and effective B1. Previous studies only demonstrated that stronger or longer pulses will obviously have better performance. The overall width of the CEST responses is dominated by the exchange kinetics and is almost independent of the pulse shape for the conditions tested here. Only at high powers, the dSNOB pulse might be slightly more selective than the BP.","Mit der Zulassung von hyperpolarisiertem 129Xe als MRT-Kontrastmittel zur Lungenbildgebung haben Anwendungen von 129Xe mit Sättigungstransfer-NMR in Bereichen wie NMR-Thermometrie und molekularer Bildgebung an Interesse gewonnen. Die gepulste Sättigung für die molekulare HyperCEST-Bildgebung wurde in der Vergangenheit bereits untersucht, allerdings ohne dass sinnvolle Aussagen über die möglichen Vorteile von selektiven HF-Pulsen möglich waren oder die damit verbundenen Erwärmungseffekte vermessen wurden. Dies motiviert neue Untersuchungen mit 129Xe-NMR und erfordert eine Kalibrierung der Thermometrie und eine Quantifizierung der HF-Erwärmung. Zum einen wurden hier die temperaturbedingten Verschiebungen für Signale von Xe in molekularen Käfigen zum ersten Mal genauer untersucht. Zum anderen quantifiziert diese Arbeit die Auswirkungen der HF-Erwärmung in der HyperCEST-NMR, indem ein systematischer Vergleich der Signal-Antworten mit zwei Arten von 129Xe-Wirten durchgeführt wurde, während die Erwärmung gemessen und eine Optimierung des Sättigungsschemas untersucht wurde. Der mittels 129Xe gemssene Erwärmungseffekt wurde in Wasser und dPBS mit unterschiedlicher HF-Leistung, Duty Cycle, Sättigungszeit und Pulsform analysiert. Zwei 129Xe-Wirte, Cryptophan-A-Monosäure (CrA-ma) und Cucurbit-[6]-uril (CB[6]) mit mäßigen bzw. schnellen Austauschraten, wurden für 5 bis 20 s gepulster Sättigung untersucht wobei die Pulsstärke im Bereich von 13 bis 58 µT lag. Die Analyse erfolgte durch Anpassung exponentieller Lorentz-Linien an die z-Spektren. Es wurde kein Unterschied in der Erwärmung zwischen 10 s Sättigung oder 1 s Sättigung mit 10 Wiederholungen festgestellt. Wie erwartet, wirkt sich die Art des Lösungsmittels auf die Erwärmung aus: die Erwärmung in einer Kochsalzlösung im Vergleich zu reinem Wasser ist unter ansonsten gleichen Bedingungen 55% höher. Betrachtet man das Leistungsäquivalent, muss ein 100 mW (31 µT) Blockpuls (BP) mit einem 286 mW (51 µT) dSNOB und einem 343 mW (57 µT) Gauß-Puls verglichen werden. Die leistungsäquivalent-bereinigten Pulse zeigen eine identische Erwärmung für alle drei Pulse. Xe, das in CB[6] austauscht, profitiert eindeutig von einer stärkeren Sättigung, während sich die Antwort von CrA-ma nicht verbessert. Die Signale der beiden Wirte sind im Vergleich zu PRF-Methode empfindlicher, denn das CrA-ma-Signal verschiebt sich um 0,26ppm/°C und das CB[6]-Signal um 0,09ppm/°C. Die Sättigung mit geformten Impulsen bringt im Vergleich zur BP-Sättigung keinen offensichtlichen Vorteil, wenn man die gleiche Dauer und das gleiche effektive B1 vergleicht. Frühere Studien haben lediglich gezeigt, dass stärkere oder längere Pulse offensichtlich eine bessere Leistung erbringen. Die Breite der CEST-Antworten wird von der Austauschkinetik dominiert und ist unter den hier getesteten Bedingungen weitgehend unabhängig von der Pulsform. Nur bei hohen Leistungen könnte der dSNOB-Puls etwas selektiver sein als der BP."],"dc:format.extent":["112"],"dc:identifier.uri":["https://refubium.fu-berlin.de/handle/fub188/51646","http://dx.doi.org/10.17169/refubium-51374"],"dc:identifier.urn":["urn:nbn:de:kobv:188-refubium-51646-6"],"dc:language":["eng"],"dc:relation.issupplementedby":["doi.org/10.1002/cphc.202401037"],"dc:rights.accessrights":["open access"],"dc:rights.proquest":["accept"],"dc:rights.uri":["http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen"],"dc:subject":["CEST","Hyperpolarized Xenon","RF Heating"],"dc:subject.ddc":["ddc:610"],"dcterms:accessrights":["free"],"dc:title":["RF Heating Effects and NMR-Based Thermometry with Hyperpolarized Xenon for Optimized CEST MRI"],"dc:title.alternative":["RF-Aufheizungen und NMR-basierte Thermometrie mit hyperpolarisiertem Xenon für Optimierte CEST-MRI"],"dc:type":["doc-type:doctoralThesis"],"dc:type.dcmitype":["Text"],"person:gender":["male"]},"updated_at":"2026-11-19T03:53:47Z"}