{"id":{"repo_id":"fu-berlin","oai_identifier":"oai:refubium.fu-berlin.de:fub188/51658"},"canonical_url":"https://search.ndltd.org/etd/fu-berlin/oai:refubium.fu-berlin.de:fub188/51658","repository":{"repo_id":"fu-berlin","name":"Freie Universität Berlin","base_url":"https://refubium.fu-berlin.de/oai/request"},"display":{"title":"In vivo Visualisation of the Renal Tubule Volume by Magnetic Resonance","abstract":"Rising rates of kidney disease are a global concern, with inadequate biomarkers and limited treatment options. The renal tubular volume fraction (TVF), the proportion of kidney tissue occupied by fluid-filled tubules, fluctuates with physiological conditions and is altered in disease, making it a promising non-invasive marker for assessing re-nal (patho-)physiology and improving diagnostic precision. Magnetic resonance imag-ing (MRI) offers a forceful approach for the assessment of soft tissue architecture in the kidney. The transverse relaxation time T2 is a quantitative metric that reflects the loss of transverse magnetization caused by spin-spin interactions. This doctoral thesis inves-tigates multiexponential T2 mapping for spatially resolved, MR-based TVF assessment as a marker of renal dysfunction and pathophysiology. Feasibility of this approach was demonstrated under two perturbations: transient elevation of intratubular pressure and pharmacological intervention with furosemide. In the first phase of the project “In vivo Monitoring of Renal Tubule Volume Fraction Using Dynamic Parametric MRI”, simulations were employed to develop and optimize imaging protocols for in vivo studies of the rat kidney. Validation was performed with a phantom mimicking renal relaxation properties. In vivo experiments on anesthetized rats (n=7) acquired T2 relaxation times using a 9.4 Tesla MRI scanner during controlled pressure elevation in the renal pelvis and tubules. In the second phase, “MRI Cartog-raphy of Renal Tubule Volume Fraction during diuretic Intervention”, the method was refined for MR-based mapping of tubule volume fraction (TVF) in response to furo-semide. Simultaneous T2, T2*, and kidney volume data were acquired before and after intravenous furosemide injection. Analysis of spatially resolved T2 decay curves was performed using non-negative least squares (NNLS) to estimate T2 components, and TVF cartographies were generated via voxel-wise bi-exponential fitting. During transient pressure elevation, significant changes in TVF were observed relative to baseline: TVFcortex=+16.4%, TVFouter_medulla= +9.6%, TVFinner_medulla=–18.2%. Furo-semide administration led to marked physiological and morphological changes com-pared to baseline values: TVFcortex=+31.1%, TVFouter_medulla=+30.7%, T2_cortex = +13.0%, T2_outer_medulla=+20.6%. Kidney size increased modestly by +2.9% T2*outer_medulla increased by +20.5%, T2*cortex remained unchanged. Taken together, this work is the first in vivo visualization of tubular volume in kidney by using magnetic resonance. These findings highlight that MR-based TVF assessment is highly responsive to both mechanical and pharmacological perturbations. MR-TVF cartography is crucial for uncovering mechanisms underlying renal (patho-)physiology, including the role of renal oxygenation assessed by MRI mapping of renal T2*.","abstract_html":"Rising rates of kidney disease are a global concern, with inadequate biomarkers and limited treatment options. The renal tubular volume fraction (TVF), the proportion of kidney tissue occupied by fluid-filled tubules, fluctuates with physiological conditions and is altered in disease, making it a promising non-invasive marker for assessing re-nal (patho-)physiology and improving diagnostic precision. Magnetic resonance imag-ing (MRI) offers a forceful approach for the assessment of soft tissue architecture in the kidney. The transverse relaxation time T2 is a quantitative metric that reflects the loss of transverse magnetization caused by spin-spin interactions. This doctoral thesis inves-tigates multiexponential T2 mapping for spatially resolved, MR-based TVF assessment as a marker of renal dysfunction and pathophysiology. Feasibility of this approach was demonstrated under two perturbations: transient elevation of intratubular pressure and pharmacological intervention with furosemide. In the first phase of the project “In vivo Monitoring of Renal Tubule Volume Fraction Using Dynamic Parametric MRI”, simulations were employed to develop and optimize imaging protocols for in vivo studies of the rat kidney. Validation was performed with a phantom mimicking renal relaxation properties. In vivo experiments on anesthetized rats (n=7) acquired T2 relaxation times using a 9.4 Tesla MRI scanner during controlled pressure elevation in the renal pelvis and tubules. In the second phase, “MRI Cartog-raphy of Renal Tubule Volume Fraction during diuretic Intervention”, the method was refined for MR-based mapping of tubule volume fraction (TVF) in response to furo-semide. Simultaneous T2, T2*, and kidney volume data were acquired before and after intravenous furosemide injection. Analysis of spatially resolved T2 decay curves was performed using non-negative least squares (NNLS) to estimate T2 components, and TVF cartographies were generated via voxel-wise bi-exponential fitting. During transient pressure elevation, significant changes in TVF were observed relative to baseline: TVFcortex=+16.4%, TVFouter_medulla= +9.6%, TVFinner_medulla=–18.2%. Furo-semide administration led to marked physiological and morphological changes com-pared to baseline values: TVFcortex=+31.1%, TVFouter_medulla=+30.7%, T2_cortex = +13.0%, T2_outer_medulla=+20.6%. Kidney size increased modestly by +2.9% T2*outer_medulla increased by +20.5%, T2*cortex remained unchanged. Taken together, this work is the first in vivo visualization of tubular volume in kidney by using magnetic resonance. These findings highlight that MR-based TVF assessment is highly responsive to both mechanical and pharmacological perturbations. MR-TVF cartography is crucial for uncovering mechanisms underlying renal (patho-)physiology, including the role of renal oxygenation assessed by MRI mapping of renal T2*.","abstract_has_math":false,"creators":["Tasbihi, Ehsan"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Charité - Universitätsmedizin Berlin","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":["N.N."],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T03:53:47Z","subjects":["kidney","quantitative Magnetic Resonance Imaging","tubule volume fraction"],"languages":["eng"],"rights":["open access"],"rights_urls":["https://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[{"key":"dc:identifier.urn","label":"URN","values":["urn:nbn:de:kobv:188-refubium-51658-6"],"render_values":[{"text":"urn:nbn:de:kobv:188-refubium-51658-6","href":"https://nbn-resolving.org/urn:nbn:de:kobv:188-refubium-51658-6","code":true}]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://refubium.fu-berlin.de/handle/fub188/51658"],"render_values":[{"text":"https://refubium.fu-berlin.de/handle/fub188/51658","href":"https://refubium.fu-berlin.de/handle/fub188/51658","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.17169/refubium-51386","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.17169/refubium-51386","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":"open","embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afu-berlin%3Aoai%3Arefubium.fu-berlin.de%3Afub188%2F51658","prefix":"oai_dc"},"source_record":{"url":"https://refubium.fu-berlin.de/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arefubium.fu-berlin.de%3Afub188%2F51658","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["N.N."]},{"key":"dc:contributor.department","label":"Department","values":["Charité - Universitätsmedizin Berlin"]},{"key":"dc:creator","label":"Author","values":["Tasbihi, Ehsan"]},{"key":"person:gender","label":"Person Gender","values":["male"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:type","label":"Dc Type","values":["doc-type:doctoralThesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["kidney","quantitative Magnetic Resonance Imaging","tubule volume fraction"]},{"key":"dc:subject.ddc","label":"Dc Subject Ddc","values":["ddc:610"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["open access"]},{"key":"dc:rights.proquest","label":"Dc Rights Proquest","values":["accept"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://refubium.fu-berlin.de/handle/fub188/51658","http://dx.doi.org/10.17169/refubium-51386"]},{"key":"dc:identifier.urn","label":"URN","values":["urn:nbn:de:kobv:188-refubium-51658-6"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Rising rates of kidney disease are a global concern, with inadequate biomarkers and limited treatment options. The renal tubular volume fraction (TVF), the proportion of kidney tissue occupied by fluid-filled tubules, fluctuates with physiological conditions and is altered in disease, making it a promising non-invasive marker for assessing re-nal (patho-)physiology and improving diagnostic precision. Magnetic resonance imag-ing (MRI) offers a forceful approach for the assessment of soft tissue architecture in the kidney. The transverse relaxation time T2 is a quantitative metric that reflects the loss of transverse magnetization caused by spin-spin interactions. This doctoral thesis inves-tigates multiexponential T2 mapping for spatially resolved, MR-based TVF assessment as a marker of renal dysfunction and pathophysiology. Feasibility of this approach was demonstrated under two perturbations: transient elevation of intratubular pressure and pharmacological intervention with furosemide. In the first phase of the project “In vivo Monitoring of Renal Tubule Volume Fraction Using Dynamic Parametric MRI”, simulations were employed to develop and optimize imaging protocols for in vivo studies of the rat kidney. Validation was performed with a phantom mimicking renal relaxation properties. In vivo experiments on anesthetized rats (n=7) acquired T2 relaxation times using a 9.4 Tesla MRI scanner during controlled pressure elevation in the renal pelvis and tubules. In the second phase, “MRI Cartog-raphy of Renal Tubule Volume Fraction during diuretic Intervention”, the method was refined for MR-based mapping of tubule volume fraction (TVF) in response to furo-semide. Simultaneous T2, T2*, and kidney volume data were acquired before and after intravenous furosemide injection. Analysis of spatially resolved T2 decay curves was performed using non-negative least squares (NNLS) to estimate T2 components, and TVF cartographies were generated via voxel-wise bi-exponential fitting. During transient pressure elevation, significant changes in TVF were observed relative to baseline: TVFcortex=+16.4%, TVFouter_medulla= +9.6%, TVFinner_medulla=–18.2%. Furo-semide administration led to marked physiological and morphological changes com-pared to baseline values: TVFcortex=+31.1%, TVFouter_medulla=+30.7%, T2_cortex = +13.0%, T2_outer_medulla=+20.6%. Kidney size increased modestly by +2.9% T2*outer_medulla increased by +20.5%, T2*cortex remained unchanged. Taken together, this work is the first in vivo visualization of tubular volume in kidney by using magnetic resonance. These findings highlight that MR-based TVF assessment is highly responsive to both mechanical and pharmacological perturbations. MR-TVF cartography is crucial for uncovering mechanisms underlying renal (patho-)physiology, including the role of renal oxygenation assessed by MRI mapping of renal T2*.","Die steigende Prävalenz von Nierenerkrankungen stellt ein globales Gesundheitsproblem da, da die aktuellen Biomarker und Therapien unzureichend sind. Die renale Tubulusvolumenfraktion (TVF), also der Anteil des Gewebes mit flüssigkeitsgefüllten Tubuli, variiert physiologisch und verändert sich bei Erkrankungen. Deshalb ist sie ein vielversprechender nicht-invasiver Marker für die renale (Patho-)Physiologie und Diagnostik. Die transversale Relaxationszeit T2 ist ein quantitativer Parameter der Magnetresonanztomographie (MRT). Sie reagiert sensitiv auf Wassergehalt des Gewebes und kann Verschiebungen im TVF anzeigen. Diese Arbeit untersucht multiexponentielle T2-Relaxation zur räumlich aufgelösten MR-basierten TVF-Bestimmung. Die Machbarkeit wurde durch pharmakologische Manipulation mit Furosemid und vorübergehende Erhöhung des intratubulären Drucks demonstriert. In der ersten Phase dieses Projekts wurden Simulationen durchgeführt, um Protokolle für die In-vivo-Untersuchung von Rattennieren zu ermitteln und zu optimieren. Der Ansatz wurde mithilfe eines Phantoms validiert, das die Relaxationseigenschaften von Nierengewebe nachahmt. In vivo wurden experimentelle Bedingungen an narkotisierten Ratten (n = 7) angewandt. Die T2-Relaxationszeiten wurden mit einem 9,4-Tesla-MR-Scanner erhoben, und zwar i) im Ruhezustand, ii) bei Druckerhöhung im Nierenbecken und in den Tubuli. In der zweiten Phase dieses Projekts habe ich die Methode zur MR-basierten Kartierung weiter verfeinert und in-vivo-Experimente mit intravenöser Gabe eines Furosemid-Bolus durchgeführt. Um die Rolle des TVF bei der Interpretation der renalen Oxygenierung zu untersuchen, wurden während der Furosemid-Intervention T2*-Messungen vorgenommen. Diese wurde anhand einer räumlich aufgelösten quantitativen Kartierung der MRT-Relaxationszeit T2* analysiert. Die multiexponentielle Analyse des T2-Signals erfolgte mithilfe einer nichtnegativen Anpassung nach der Methode der kleinsten Quadrate an ortsaufgelöste T2-Abklingkurven zur Extraktion der T2-Spektren. Anschließend wurden die TVF-Karten mittels voxelweiser biexponentieller Anpassung berechnet. Während der transienten Druckerhöhung wurden signifikante Veränderungen des TVF gegenüber dem Ausgangswert beobachtet. TVFRinde=+16,4%, TVFäußeres Mark=+9,6%, TVFinneres Mark=–18,2%. Die Gabe von Furosemid führte zu deutlichen physiologischen und morphologischen Veränderungen im Vergleich zu den Ausgangswerten: TVFRinde=+31,1%, TVFäußeres Mark=+30,7%, T2 Rinde =+13,0%, T2 äußeres Mark=+20,6%. Die Nierengröße nahm moderat um +2,9% zu, T2*äußeres Mark um +20,5%, während T2*Rinde unverändert blieb. Zusammenfassend stellt diese Arbeit die erste in-vivo-Visualisierung des tubulären Volumens in der Niere mittels Magnetresonanztomographie dar. Die Ergebnisse zeigen, dass die MR-basierte TVF-Kartierung sowohl auf mechanische als auch auf pharmakologische Störungen sehr empfindlich reagiert. Die MR-TVF-Kartierung ist von großer Bedeutung für das Verständnis der renalen (Patho-)Physiologie, einschließlich der Rolle der renalen Oxygenierung, die durch T2*-Mapping der Niere erfasst wird."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["IV, 109 Seiten"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["free"]},{"key":"dc:title","label":"Title","values":["In vivo Visualisation of the Renal Tubule Volume by Magnetic Resonance"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["In vivo Visualisierung des Tubulusvolumens in der Niere mittels Magnetresonanztomographie"]}]}],"canonical_facts":{"dc:contributor.committeemember":["N.N."],"dc:contributor.department":["Charité - Universitätsmedizin Berlin"],"dc:creator":["Tasbihi, Ehsan"],"dc:date.issued":["2026"],"dc:description.abstract":["Rising rates of kidney disease are a global concern, with inadequate biomarkers and limited treatment options. The renal tubular volume fraction (TVF), the proportion of kidney tissue occupied by fluid-filled tubules, fluctuates with physiological conditions and is altered in disease, making it a promising non-invasive marker for assessing re-nal (patho-)physiology and improving diagnostic precision. Magnetic resonance imag-ing (MRI) offers a forceful approach for the assessment of soft tissue architecture in the kidney. The transverse relaxation time T2 is a quantitative metric that reflects the loss of transverse magnetization caused by spin-spin interactions. This doctoral thesis inves-tigates multiexponential T2 mapping for spatially resolved, MR-based TVF assessment as a marker of renal dysfunction and pathophysiology. Feasibility of this approach was demonstrated under two perturbations: transient elevation of intratubular pressure and pharmacological intervention with furosemide. In the first phase of the project “In vivo Monitoring of Renal Tubule Volume Fraction Using Dynamic Parametric MRI”, simulations were employed to develop and optimize imaging protocols for in vivo studies of the rat kidney. Validation was performed with a phantom mimicking renal relaxation properties. In vivo experiments on anesthetized rats (n=7) acquired T2 relaxation times using a 9.4 Tesla MRI scanner during controlled pressure elevation in the renal pelvis and tubules. In the second phase, “MRI Cartog-raphy of Renal Tubule Volume Fraction during diuretic Intervention”, the method was refined for MR-based mapping of tubule volume fraction (TVF) in response to furo-semide. Simultaneous T2, T2*, and kidney volume data were acquired before and after intravenous furosemide injection. Analysis of spatially resolved T2 decay curves was performed using non-negative least squares (NNLS) to estimate T2 components, and TVF cartographies were generated via voxel-wise bi-exponential fitting. During transient pressure elevation, significant changes in TVF were observed relative to baseline: TVFcortex=+16.4%, TVFouter_medulla= +9.6%, TVFinner_medulla=–18.2%. Furo-semide administration led to marked physiological and morphological changes com-pared to baseline values: TVFcortex=+31.1%, TVFouter_medulla=+30.7%, T2_cortex = +13.0%, T2_outer_medulla=+20.6%. Kidney size increased modestly by +2.9% T2*outer_medulla increased by +20.5%, T2*cortex remained unchanged. Taken together, this work is the first in vivo visualization of tubular volume in kidney by using magnetic resonance. These findings highlight that MR-based TVF assessment is highly responsive to both mechanical and pharmacological perturbations. MR-TVF cartography is crucial for uncovering mechanisms underlying renal (patho-)physiology, including the role of renal oxygenation assessed by MRI mapping of renal T2*.","Die steigende Prävalenz von Nierenerkrankungen stellt ein globales Gesundheitsproblem da, da die aktuellen Biomarker und Therapien unzureichend sind. Die renale Tubulusvolumenfraktion (TVF), also der Anteil des Gewebes mit flüssigkeitsgefüllten Tubuli, variiert physiologisch und verändert sich bei Erkrankungen. Deshalb ist sie ein vielversprechender nicht-invasiver Marker für die renale (Patho-)Physiologie und Diagnostik. Die transversale Relaxationszeit T2 ist ein quantitativer Parameter der Magnetresonanztomographie (MRT). Sie reagiert sensitiv auf Wassergehalt des Gewebes und kann Verschiebungen im TVF anzeigen. Diese Arbeit untersucht multiexponentielle T2-Relaxation zur räumlich aufgelösten MR-basierten TVF-Bestimmung. Die Machbarkeit wurde durch pharmakologische Manipulation mit Furosemid und vorübergehende Erhöhung des intratubulären Drucks demonstriert. In der ersten Phase dieses Projekts wurden Simulationen durchgeführt, um Protokolle für die In-vivo-Untersuchung von Rattennieren zu ermitteln und zu optimieren. Der Ansatz wurde mithilfe eines Phantoms validiert, das die Relaxationseigenschaften von Nierengewebe nachahmt. In vivo wurden experimentelle Bedingungen an narkotisierten Ratten (n = 7) angewandt. Die T2-Relaxationszeiten wurden mit einem 9,4-Tesla-MR-Scanner erhoben, und zwar i) im Ruhezustand, ii) bei Druckerhöhung im Nierenbecken und in den Tubuli. In der zweiten Phase dieses Projekts habe ich die Methode zur MR-basierten Kartierung weiter verfeinert und in-vivo-Experimente mit intravenöser Gabe eines Furosemid-Bolus durchgeführt. Um die Rolle des TVF bei der Interpretation der renalen Oxygenierung zu untersuchen, wurden während der Furosemid-Intervention T2*-Messungen vorgenommen. Diese wurde anhand einer räumlich aufgelösten quantitativen Kartierung der MRT-Relaxationszeit T2* analysiert. Die multiexponentielle Analyse des T2-Signals erfolgte mithilfe einer nichtnegativen Anpassung nach der Methode der kleinsten Quadrate an ortsaufgelöste T2-Abklingkurven zur Extraktion der T2-Spektren. Anschließend wurden die TVF-Karten mittels voxelweiser biexponentieller Anpassung berechnet. Während der transienten Druckerhöhung wurden signifikante Veränderungen des TVF gegenüber dem Ausgangswert beobachtet. TVFRinde=+16,4%, TVFäußeres Mark=+9,6%, TVFinneres Mark=–18,2%. Die Gabe von Furosemid führte zu deutlichen physiologischen und morphologischen Veränderungen im Vergleich zu den Ausgangswerten: TVFRinde=+31,1%, TVFäußeres Mark=+30,7%, T2 Rinde =+13,0%, T2 äußeres Mark=+20,6%. Die Nierengröße nahm moderat um +2,9% zu, T2*äußeres Mark um +20,5%, während T2*Rinde unverändert blieb. Zusammenfassend stellt diese Arbeit die erste in-vivo-Visualisierung des tubulären Volumens in der Niere mittels Magnetresonanztomographie dar. Die Ergebnisse zeigen, dass die MR-basierte TVF-Kartierung sowohl auf mechanische als auch auf pharmakologische Störungen sehr empfindlich reagiert. Die MR-TVF-Kartierung ist von großer Bedeutung für das Verständnis der renalen (Patho-)Physiologie, einschließlich der Rolle der renalen Oxygenierung, die durch T2*-Mapping der Niere erfasst wird."],"dc:format.extent":["IV, 109 Seiten"],"dc:identifier.uri":["https://refubium.fu-berlin.de/handle/fub188/51658","http://dx.doi.org/10.17169/refubium-51386"],"dc:identifier.urn":["urn:nbn:de:kobv:188-refubium-51658-6"],"dc:language":["eng"],"dc:rights.accessrights":["open access"],"dc:rights.proquest":["accept"],"dc:rights.uri":["https://creativecommons.org/licenses/by/4.0/"],"dc:subject":["kidney","quantitative Magnetic Resonance Imaging","tubule volume fraction"],"dc:subject.ddc":["ddc:610"],"dcterms:accessrights":["free"],"dc:title":["In vivo Visualisation of the Renal Tubule Volume by Magnetic Resonance"],"dc:title.alternative":["In vivo Visualisierung des Tubulusvolumens in der Niere mittels Magnetresonanztomographie"],"dc:type":["doc-type:doctoralThesis"],"dc:type.dcmitype":["Text"],"person:gender":["male"]},"updated_at":"2026-11-19T03:53:47Z"}