{"id":{"repo_id":"fu-berlin","oai_identifier":"oai:refubium.fu-berlin.de:fub188/52671"},"canonical_url":"https://search.ndltd.org/etd/fu-berlin/oai:refubium.fu-berlin.de:fub188/52671","repository":{"repo_id":"fu-berlin","name":"Freie Universität Berlin","base_url":"https://refubium.fu-berlin.de/oai/request"},"display":{"title":"Scherhaftfestigkeit von CAD/CAM-Hybridmaterialien für die subtraktive und additive Fertigung unter Verwendung verschiedener Reparaturprotokolle","abstract":"Objectives: Clinical failures of CAD/CAM restorations such as chipping or fractures necessitate reliable intraoral repair options as an alternative to complete replacement. With the increasing use of additively manufactured (3D-printed) hybrid materials for definitive restorations, the question arises whether these materials demonstrate comparable repairability to subtractively manufactured (milled) materials. The aim of this in vitro study was to evaluate the shear bond strength (SBS) of different CAD/CAM hybrid materials for subtractive and additive manufacturing using three commercially available repair protocols and to investigate the influence of artificial aging by thermocycling. Methods: Two milled hybrid materials (Vita Enamic, VE; Voco Grandio Blocs, VG) and one experimental 3D-printed hybrid material (3D) were tested. Rectangular specimens (n = 180) were prepared following the principles of DIN EN ISO 10477. Three repair protocols were applied: Monobond Plus combined with Optibond FL (MO), GC Repair Kit consisting of G-Multi Primer and G-Premio Bond (GC), and Voco Cimara consisting of silane and adhesive (VC). Repairs were performed using a nanoceramic composite (Ceram.X Spectra ST). Half of the specimens per group (n = 10) underwent artificial aging by 30.000 thermocycles (5–55 °C). Shear bond strength was measured using a universal testing machine (RetroLine Z010, Zwick/Roell). Fracture surfaces were analyzed by light microscopy and scanning electron microscopy. Statistical analysis was performed using multi-factor ANOVA and post-hoc tests (α = 0.05). Results: The repair protocol and material type significantly influenced SBS. MO achieved the highest SBS values both before and after thermocycling, while GC consistently yielded the lowest values. Thermocycling significantly reduced SBS in milled materials (VE, VG) across almost all repair protocols. In contrast, the 3D-printed material showed an opposite effect: only the combination of GC with 3D demonstrated an increase in SBS after thermocycling. In 57 out of 60 specimens of the 3D-printed material, substrate failure occurred, indicating that the repair SBS exceeded the intrinsic strength of the material. Regarding failure modes, mixed adhesive-cohesive failures predominated before thermocycling, while adhesive failures became more prevalent after aging. 14 Conclusions: SBS was significantly influenced by material type and repair protocol. MO proved to be the most effective repair system for all tested materials. Thermocycling reduced SBS in milled materials, while the 3D-printed material demonstrated stable or improved repair bond strength after artificial aging. The results emphasize the need for material-specific repair strategies and suggest that additively manufactured hybrid materials represent a promising clinical alternative with regard to repairability.","abstract_html":"Objectives: Clinical failures of CAD/CAM restorations such as chipping or fractures necessitate reliable intraoral repair options as an alternative to complete replacement. With the increasing use of additively manufactured (3D-printed) hybrid materials for definitive restorations, the question arises whether these materials demonstrate comparable repairability to subtractively manufactured (milled) materials. The aim of this in vitro study was to evaluate the shear bond strength (SBS) of different CAD/CAM hybrid materials for subtractive and additive manufacturing using three commercially available repair protocols and to investigate the influence of artificial aging by thermocycling. Methods: Two milled hybrid materials (Vita Enamic, VE; Voco Grandio Blocs, VG) and one experimental 3D-printed hybrid material (3D) were tested. Rectangular specimens (n = 180) were prepared following the principles of DIN EN ISO 10477. Three repair protocols were applied: Monobond Plus combined with Optibond FL (MO), GC Repair Kit consisting of G-Multi Primer and G-Premio Bond (GC), and Voco Cimara consisting of silane and adhesive (VC). Repairs were performed using a nanoceramic composite (Ceram.X Spectra ST). Half of the specimens per group (n = 10) underwent artificial aging by 30.000 thermocycles (5–55 °C). Shear bond strength was measured using a universal testing machine (RetroLine Z010, Zwick/Roell). Fracture surfaces were analyzed by light microscopy and scanning electron microscopy. Statistical analysis was performed using multi-factor ANOVA and post-hoc tests (α = 0.05). Results: The repair protocol and material type significantly influenced SBS. MO achieved the highest SBS values both before and after thermocycling, while GC consistently yielded the lowest values. Thermocycling significantly reduced SBS in milled materials (VE, VG) across almost all repair protocols. In contrast, the 3D-printed material showed an opposite effect: only the combination of GC with 3D demonstrated an increase in SBS after thermocycling. In 57 out of 60 specimens of the 3D-printed material, substrate failure occurred, indicating that the repair SBS exceeded the intrinsic strength of the material. Regarding failure modes, mixed adhesive-cohesive failures predominated before thermocycling, while adhesive failures became more prevalent after aging. 14 Conclusions: SBS was significantly influenced by material type and repair protocol. MO proved to be the most effective repair system for all tested materials. Thermocycling reduced SBS in milled materials, while the 3D-printed material demonstrated stable or improved repair bond strength after artificial aging. The results emphasize the need for material-specific repair strategies and suggest that additively manufactured hybrid materials represent a promising clinical alternative with regard to repairability.","abstract_has_math":false,"creators":["Milicevic, Marko"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Charité - Universitätsmedizin Berlin","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":["N.N."],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T03:54:07Z","subjects":["CAD/CAM hybrid materials","Shear bond strength","Repair protocols","Additive manufacturing","Subtractive manufacturing","3D printin","Thermocycling","Intraoral repair"],"languages":["ger"],"rights":["open access"],"rights_urls":["https://www.fu-berlin.de/sites/ub/publizieren/refubium/rechtliches/nutzungsbedingungen.html"],"identifier_entries":[{"key":"dc:identifier.urn","label":"URN","values":["urn:nbn:de:kobv:188-refubium-52671-9"],"render_values":[{"text":"urn:nbn:de:kobv:188-refubium-52671-9","href":"https://nbn-resolving.org/urn:nbn:de:kobv:188-refubium-52671-9","code":true}]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://refubium.fu-berlin.de/handle/fub188/52671"],"render_values":[{"text":"https://refubium.fu-berlin.de/handle/fub188/52671","href":"https://refubium.fu-berlin.de/handle/fub188/52671","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.17169/refubium-52401","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.17169/refubium-52401","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":"open","embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Afu-berlin%3Aoai%3Arefubium.fu-berlin.de%3Afub188%2F52671","prefix":"oai_dc"},"source_record":{"url":"https://refubium.fu-berlin.de/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arefubium.fu-berlin.de%3Afub188%2F52671","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["N.N."]},{"key":"dc:contributor.department","label":"Department","values":["Charité - Universitätsmedizin Berlin"]},{"key":"dc:creator","label":"Author","values":["Milicevic, Marko"]},{"key":"person:gender","label":"Person Gender","values":["male"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:type","label":"Dc Type","values":["doc-type:doctoralThesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["CAD/CAM hybrid materials","Shear bond strength","Repair protocols","Additive manufacturing","Subtractive manufacturing","3D printin","Thermocycling","Intraoral repair"]},{"key":"dc:subject.ddc","label":"Dc Subject Ddc","values":["ddc:610"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["ger"]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["open access"]},{"key":"dc:rights.proquest","label":"Dc Rights Proquest","values":["accept"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://www.fu-berlin.de/sites/ub/publizieren/refubium/rechtliches/nutzungsbedingungen.html"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://refubium.fu-berlin.de/handle/fub188/52671","http://dx.doi.org/10.17169/refubium-52401"]},{"key":"dc:identifier.urn","label":"URN","values":["urn:nbn:de:kobv:188-refubium-52671-9"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Objectives: Clinical failures of CAD/CAM restorations such as chipping or fractures necessitate reliable intraoral repair options as an alternative to complete replacement. With the increasing use of additively manufactured (3D-printed) hybrid materials for definitive restorations, the question arises whether these materials demonstrate comparable repairability to subtractively manufactured (milled) materials. The aim of this in vitro study was to evaluate the shear bond strength (SBS) of different CAD/CAM hybrid materials for subtractive and additive manufacturing using three commercially available repair protocols and to investigate the influence of artificial aging by thermocycling. Methods: Two milled hybrid materials (Vita Enamic, VE; Voco Grandio Blocs, VG) and one experimental 3D-printed hybrid material (3D) were tested. Rectangular specimens (n = 180) were prepared following the principles of DIN EN ISO 10477. Three repair protocols were applied: Monobond Plus combined with Optibond FL (MO), GC Repair Kit consisting of G-Multi Primer and G-Premio Bond (GC), and Voco Cimara consisting of silane and adhesive (VC). Repairs were performed using a nanoceramic composite (Ceram.X Spectra ST). Half of the specimens per group (n = 10) underwent artificial aging by 30.000 thermocycles (5–55 °C). Shear bond strength was measured using a universal testing machine (RetroLine Z010, Zwick/Roell). Fracture surfaces were analyzed by light microscopy and scanning electron microscopy. Statistical analysis was performed using multi-factor ANOVA and post-hoc tests (α = 0.05). Results: The repair protocol and material type significantly influenced SBS. MO achieved the highest SBS values both before and after thermocycling, while GC consistently yielded the lowest values. Thermocycling significantly reduced SBS in milled materials (VE, VG) across almost all repair protocols. In contrast, the 3D-printed material showed an opposite effect: only the combination of GC with 3D demonstrated an increase in SBS after thermocycling. In 57 out of 60 specimens of the 3D-printed material, substrate failure occurred, indicating that the repair SBS exceeded the intrinsic strength of the material. Regarding failure modes, mixed adhesive-cohesive failures predominated before thermocycling, while adhesive failures became more prevalent after aging. 14 Conclusions: SBS was significantly influenced by material type and repair protocol. MO proved to be the most effective repair system for all tested materials. Thermocycling reduced SBS in milled materials, while the 3D-printed material demonstrated stable or improved repair bond strength after artificial aging. The results emphasize the need for material-specific repair strategies and suggest that additively manufactured hybrid materials represent a promising clinical alternative with regard to repairability.","Ziel: Klinische Misserfolge von CAD/CAM-Restaurationen wie Chipping oder Frakturen erfordern eine zuverlässige intraorale Reparaturmöglichkeit als Alternative zur Neuanfertigung. Mit der zunehmenden Verbreitung additiv gefertigter (3D-gedruckter) Hybridmaterialien für definitive Restaurationen stellt sich die Frage, ob diese Materialien eine vergleichbare Reparaturfähigkeit aufweisen wie subtraktiv gefertigte (gefräste) Materialien. Ziel dieser In-vitro-Studie war es, die Scherhaftfestigkeit (SBS) verschiedener CAD/CAM-Hybridmaterialien für die subtraktive und additive Fertigung unter Verwendung dreier kommerziell erhältlicher Reparaturprotokolle zu evaluieren und den Einfluss von künstlicher Alterung mittels Thermocycling zu untersuchen. Material und Methode: Es wurden zwei gefräste Hybridmaterialien (Vita Enamic, VE; Voco Grandio Blocs, VG) und ein experimentelles 3D-gedrucktes Hybridmaterial (3D) untersucht. Rechteckige Probenkörper (n = 180) wurden in Anlehnung an DIN EN ISO 10477 hergestellt. Drei Reparaturprotokolle kamen zum Einsatz: Monobond Plus kombiniert mit Optibond FL (MO), GC Repair Kit bestehend aus G-Multi Primer und G-Premio Bond (GC) sowie Voco Cimara bestehend aus Silan und Adhäsiv (VC). Die Reparatur erfolgte mit einem nanokeramischen Komposite (Ceram.X Spectra ST). Die Hälfte der Proben jeder Gruppe (n = 10) wurde einer künstlichen Alterung durch 30.000 Thermozyklen (5–55 °C) unterzogen. Die Scherhaftfestigkeit wurde mittels Universalprüfmaschine (RetroLine Z010, Zwick/Roell) bestimmt. Die Bruchflächen wurden licht- und rasterelektronenmikroskopisch analysiert. Die statistische Auswertung erfolgte mittels Mehrfaktor-Varianzanalyse und Post-hoc-Tests (α = 0,05). Ergebnisse: Das Reparaturprotokoll und der Materialtyp beeinflussten die SBS signifikant. MO erzielte die höchsten SBS-Werte sowohl vor als auch nach Thermocycling, während GC durchgehend die niedrigsten Werte aufwies. Thermocycling führte bei den gefrästen Materialien (VE, VG) zu einer signifikanten Reduktion der SBS über fast alle Reparaturprotokolle. Beim Dreidimensional gedruckt (3D) gedruckten Material zeigte sich hingegen ein entgegengesetzter Effekt: Die Kombination GC mit 3D war die einzige Gruppe, in der die SBS nach Thermocycling anstieg. In 57 von 60 Proben des 3D-Materials trat ein Substratversagen auf, was primär auf die limitierte intrinsische Festigkeit des 12 Materials zurückzuführen ist. Bezüglich der Versagensmodi überwogen vor Thermocycling gemischte adhäsiv-kohäsive Brüche, während nach Thermocycling verstärkt adhäsive Versagensmuster auftraten. Schlussfolgerung: Die SBS wurde signifikant durch den Materialtyp und das verwendete Reparaturprotokoll beeinflusst. MO erwies sich als das leistungsstärkste Reparatursystem für alle getesteten Materialien. Thermocycling reduzierte die SBS bei gefrästen Materialien, während das 3D-gedruckte Material eine stabilere bzw. verbesserte Reparaturhaftung nach künstlicher Alterung zeigte. Die Ergebnisse unterstreichen die Notwendigkeit materialspezifischer Reparaturstrategien und legen nahe, dass additiv gefertigte Hybridmaterialien hinsichtlich ihrer Reparaturfähigkeit eine vielversprechende klinische Alternative darstellen."]},{"key":"dc:description.note","label":"Dc Description Note","values":["Dissertation submitted to the Medical Faculty of Charité – Universitätsmedizin Berlin for the degree Dr. med. dent.","Dissertation zur Erlangung des akademischen Grades Dr. med. dent. an der Medizinischen Fakultät Charité – Universitätsmedizin Berlin"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["58"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["free"]},{"key":"dc:title","label":"Title","values":["Scherhaftfestigkeit von CAD/CAM-Hybridmaterialien für die subtraktive und additive Fertigung unter Verwendung verschiedener Reparaturprotokolle"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Shear bond strength of CAD/CAM hybrid materials for subtractive and additive manufacturing using different repair protocols"]}]}],"canonical_facts":{"dc:contributor.committeemember":["N.N."],"dc:contributor.department":["Charité - Universitätsmedizin Berlin"],"dc:creator":["Milicevic, Marko"],"dc:date.issued":["2026"],"dc:description.abstract":["Objectives: Clinical failures of CAD/CAM restorations such as chipping or fractures necessitate reliable intraoral repair options as an alternative to complete replacement. With the increasing use of additively manufactured (3D-printed) hybrid materials for definitive restorations, the question arises whether these materials demonstrate comparable repairability to subtractively manufactured (milled) materials. The aim of this in vitro study was to evaluate the shear bond strength (SBS) of different CAD/CAM hybrid materials for subtractive and additive manufacturing using three commercially available repair protocols and to investigate the influence of artificial aging by thermocycling. Methods: Two milled hybrid materials (Vita Enamic, VE; Voco Grandio Blocs, VG) and one experimental 3D-printed hybrid material (3D) were tested. Rectangular specimens (n = 180) were prepared following the principles of DIN EN ISO 10477. Three repair protocols were applied: Monobond Plus combined with Optibond FL (MO), GC Repair Kit consisting of G-Multi Primer and G-Premio Bond (GC), and Voco Cimara consisting of silane and adhesive (VC). Repairs were performed using a nanoceramic composite (Ceram.X Spectra ST). Half of the specimens per group (n = 10) underwent artificial aging by 30.000 thermocycles (5–55 °C). Shear bond strength was measured using a universal testing machine (RetroLine Z010, Zwick/Roell). Fracture surfaces were analyzed by light microscopy and scanning electron microscopy. Statistical analysis was performed using multi-factor ANOVA and post-hoc tests (α = 0.05). Results: The repair protocol and material type significantly influenced SBS. MO achieved the highest SBS values both before and after thermocycling, while GC consistently yielded the lowest values. Thermocycling significantly reduced SBS in milled materials (VE, VG) across almost all repair protocols. In contrast, the 3D-printed material showed an opposite effect: only the combination of GC with 3D demonstrated an increase in SBS after thermocycling. In 57 out of 60 specimens of the 3D-printed material, substrate failure occurred, indicating that the repair SBS exceeded the intrinsic strength of the material. Regarding failure modes, mixed adhesive-cohesive failures predominated before thermocycling, while adhesive failures became more prevalent after aging. 14 Conclusions: SBS was significantly influenced by material type and repair protocol. MO proved to be the most effective repair system for all tested materials. Thermocycling reduced SBS in milled materials, while the 3D-printed material demonstrated stable or improved repair bond strength after artificial aging. The results emphasize the need for material-specific repair strategies and suggest that additively manufactured hybrid materials represent a promising clinical alternative with regard to repairability.","Ziel: Klinische Misserfolge von CAD/CAM-Restaurationen wie Chipping oder Frakturen erfordern eine zuverlässige intraorale Reparaturmöglichkeit als Alternative zur Neuanfertigung. Mit der zunehmenden Verbreitung additiv gefertigter (3D-gedruckter) Hybridmaterialien für definitive Restaurationen stellt sich die Frage, ob diese Materialien eine vergleichbare Reparaturfähigkeit aufweisen wie subtraktiv gefertigte (gefräste) Materialien. Ziel dieser In-vitro-Studie war es, die Scherhaftfestigkeit (SBS) verschiedener CAD/CAM-Hybridmaterialien für die subtraktive und additive Fertigung unter Verwendung dreier kommerziell erhältlicher Reparaturprotokolle zu evaluieren und den Einfluss von künstlicher Alterung mittels Thermocycling zu untersuchen. Material und Methode: Es wurden zwei gefräste Hybridmaterialien (Vita Enamic, VE; Voco Grandio Blocs, VG) und ein experimentelles 3D-gedrucktes Hybridmaterial (3D) untersucht. Rechteckige Probenkörper (n = 180) wurden in Anlehnung an DIN EN ISO 10477 hergestellt. Drei Reparaturprotokolle kamen zum Einsatz: Monobond Plus kombiniert mit Optibond FL (MO), GC Repair Kit bestehend aus G-Multi Primer und G-Premio Bond (GC) sowie Voco Cimara bestehend aus Silan und Adhäsiv (VC). Die Reparatur erfolgte mit einem nanokeramischen Komposite (Ceram.X Spectra ST). Die Hälfte der Proben jeder Gruppe (n = 10) wurde einer künstlichen Alterung durch 30.000 Thermozyklen (5–55 °C) unterzogen. Die Scherhaftfestigkeit wurde mittels Universalprüfmaschine (RetroLine Z010, Zwick/Roell) bestimmt. Die Bruchflächen wurden licht- und rasterelektronenmikroskopisch analysiert. Die statistische Auswertung erfolgte mittels Mehrfaktor-Varianzanalyse und Post-hoc-Tests (α = 0,05). Ergebnisse: Das Reparaturprotokoll und der Materialtyp beeinflussten die SBS signifikant. MO erzielte die höchsten SBS-Werte sowohl vor als auch nach Thermocycling, während GC durchgehend die niedrigsten Werte aufwies. Thermocycling führte bei den gefrästen Materialien (VE, VG) zu einer signifikanten Reduktion der SBS über fast alle Reparaturprotokolle. Beim Dreidimensional gedruckt (3D) gedruckten Material zeigte sich hingegen ein entgegengesetzter Effekt: Die Kombination GC mit 3D war die einzige Gruppe, in der die SBS nach Thermocycling anstieg. In 57 von 60 Proben des 3D-Materials trat ein Substratversagen auf, was primär auf die limitierte intrinsische Festigkeit des 12 Materials zurückzuführen ist. Bezüglich der Versagensmodi überwogen vor Thermocycling gemischte adhäsiv-kohäsive Brüche, während nach Thermocycling verstärkt adhäsive Versagensmuster auftraten. Schlussfolgerung: Die SBS wurde signifikant durch den Materialtyp und das verwendete Reparaturprotokoll beeinflusst. MO erwies sich als das leistungsstärkste Reparatursystem für alle getesteten Materialien. Thermocycling reduzierte die SBS bei gefrästen Materialien, während das 3D-gedruckte Material eine stabilere bzw. verbesserte Reparaturhaftung nach künstlicher Alterung zeigte. Die Ergebnisse unterstreichen die Notwendigkeit materialspezifischer Reparaturstrategien und legen nahe, dass additiv gefertigte Hybridmaterialien hinsichtlich ihrer Reparaturfähigkeit eine vielversprechende klinische Alternative darstellen."],"dc:description.note":["Dissertation submitted to the Medical Faculty of Charité – Universitätsmedizin Berlin for the degree Dr. med. dent.","Dissertation zur Erlangung des akademischen Grades Dr. med. dent. an der Medizinischen Fakultät Charité – Universitätsmedizin Berlin"],"dc:format.extent":["58"],"dc:identifier.uri":["https://refubium.fu-berlin.de/handle/fub188/52671","http://dx.doi.org/10.17169/refubium-52401"],"dc:identifier.urn":["urn:nbn:de:kobv:188-refubium-52671-9"],"dc:language":["ger"],"dc:rights.accessrights":["open access"],"dc:rights.proquest":["accept"],"dc:rights.uri":["https://www.fu-berlin.de/sites/ub/publizieren/refubium/rechtliches/nutzungsbedingungen.html"],"dc:subject":["CAD/CAM hybrid materials","Shear bond strength","Repair protocols","Additive manufacturing","Subtractive manufacturing","3D printin","Thermocycling","Intraoral repair"],"dc:subject.ddc":["ddc:610"],"dcterms:accessrights":["free"],"dc:title":["Scherhaftfestigkeit von CAD/CAM-Hybridmaterialien für die subtraktive und additive Fertigung unter Verwendung verschiedener Reparaturprotokolle"],"dc:title.alternative":["Shear bond strength of CAD/CAM hybrid materials for subtractive and additive manufacturing using different repair protocols"],"dc:type":["doc-type:doctoralThesis"],"dc:type.dcmitype":["Text"],"person:gender":["male"]},"updated_at":"2026-11-19T03:54:07Z"}