{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/10432"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/10432","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"A New Magnetic Resonance Imaging Contrast Agent for the Detection of Glutathione","abstract":"Magnetic resonance imaging (MRI) is one of the most powerful imaging techniques for research and clinical diagnosis. To expand upon the intrinsic capabilities of MRI, new contrast agents that can detect the presence of biomarkers in vivo are being developed. My Masters thesis research focuses on the design and synthesis of a new MRI contrast agent that can detect glutathione (GSH), a biomarker that has been implicated in a number of oxidative stress diseases. This new MRI contrast agent is based on chelated dysprosium (Dy), an inorganic metal, which provides negative contrast to surrounding tissue. Preliminary data has shown that attaching a poly(ethylene glycol) (PEG) chain to the Dy chelate, effectively increasing its molecular weight, enhances the contrast ability of Dy. Using this new information, the contrast agent was designed to have a large molecular weight PEG chain attached to the Dy chelate through a disulfide, creating a thiol-sensitive linkage. In the presence of a thiol-containing molecule such as GSH, the Dy will be dePEGylated through a disulfide exchange reaction, removing the molecular weight effect of the PEG, and allowing for the detection of GSH by MRI. This new MRI contrast agent could provide insight into the progression and diagnosis of oxidative stress pathologies associated with GSH.","abstract_html":"Magnetic resonance imaging (MRI) is one of the most powerful imaging techniques for research and clinical diagnosis. To expand upon the intrinsic capabilities of MRI, new contrast agents that can detect the presence of biomarkers in vivo are being developed. My Masters thesis research focuses on the design and synthesis of a new MRI contrast agent that can detect glutathione (GSH), a biomarker that has been implicated in a number of oxidative stress diseases. This new MRI contrast agent is based on chelated dysprosium (Dy), an inorganic metal, which provides negative contrast to surrounding tissue. Preliminary data has shown that attaching a poly(ethylene glycol) (PEG) chain to the Dy chelate, effectively increasing its molecular weight, enhances the contrast ability of Dy. Using this new information, the contrast agent was designed to have a large molecular weight PEG chain attached to the Dy chelate through a disulfide, creating a thiol-sensitive linkage. In the presence of a thiol-containing molecule such as GSH, the Dy will be dePEGylated through a disulfide exchange reaction, removing the molecular weight effect of the PEG, and allowing for the detection of GSH by MRI. This new MRI contrast agent could provide insight into the progression and diagnosis of oxidative stress pathologies associated with GSH.","abstract_has_math":false,"creators":["Guinn, Amy Rebecca"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Biomedical Engineering","school":null,"contributors":[],"advisors":["Murthy, Niren"],"committee_chairs":[],"committee_members":["Hu, Xiaoping","Jones, Dean"],"year":2006,"date_issued":"2006-01-11","date_published":"2006-01-11","updated_at":"2026-11-19T05:16:01Z","subjects":["MRI","Contrast agent","Glutathione","t1","t2"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/10432","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/10432","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F10432","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Murthy, Niren"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hu, Xiaoping","Jones, Dean"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Guinn, Amy Rebecca"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-06-09T17:50:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-06-09T17:50:46Z"]},{"key":"dc:date.issued","label":"Date","values":["2006-01-11"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Bioengineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["a5c9fe8c-5d03-4de6-a761-459fb2af0dea"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["MRI","Contrast agent","Glutathione","t1","t2"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/10432"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Magnetic resonance imaging (MRI) is one of the most powerful imaging techniques for research and clinical diagnosis. To expand upon the intrinsic capabilities of MRI, new contrast agents that can detect the presence of biomarkers in vivo are being developed. My Masters thesis research focuses on the design and synthesis of a new MRI contrast agent that can detect glutathione (GSH), a biomarker that has been implicated in a number of oxidative stress diseases. This new MRI contrast agent is based on chelated dysprosium (Dy), an inorganic metal, which provides negative contrast to surrounding tissue. Preliminary data has shown that attaching a poly(ethylene glycol) (PEG) chain to the Dy chelate, effectively increasing its molecular weight, enhances the contrast ability of Dy. Using this new information, the contrast agent was designed to have a large molecular weight PEG chain attached to the Dy chelate through a disulfide, creating a thiol-sensitive linkage. In the presence of a thiol-containing molecule such as GSH, the Dy will be dePEGylated through a disulfide exchange reaction, removing the molecular weight effect of the PEG, and allowing for the detection of GSH by MRI. This new MRI contrast agent could provide insight into the progression and diagnosis of oxidative stress pathologies associated with GSH."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["483651 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A New Magnetic Resonance Imaging Contrast Agent for the Detection of Glutathione"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Murthy, Niren"],"dc:contributor.committeemember":["Hu, Xiaoping","Jones, Dean"],"dc:contributor.department":["Biomedical Engineering"],"dc:contributor.other":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"],"dc:creator":["Guinn, Amy Rebecca"],"dc:date.accessioned":["2006-06-09T17:50:46Z"],"dc:date.available":["2006-06-09T17:50:46Z"],"dc:date.issued":["2006-01-11"],"dc:description.abstract":["Magnetic resonance imaging (MRI) is one of the most powerful imaging techniques for research and clinical diagnosis. To expand upon the intrinsic capabilities of MRI, new contrast agents that can detect the presence of biomarkers in vivo are being developed. My Masters thesis research focuses on the design and synthesis of a new MRI contrast agent that can detect glutathione (GSH), a biomarker that has been implicated in a number of oxidative stress diseases. This new MRI contrast agent is based on chelated dysprosium (Dy), an inorganic metal, which provides negative contrast to surrounding tissue. Preliminary data has shown that attaching a poly(ethylene glycol) (PEG) chain to the Dy chelate, effectively increasing its molecular weight, enhances the contrast ability of Dy. Using this new information, the contrast agent was designed to have a large molecular weight PEG chain attached to the Dy chelate through a disulfide, creating a thiol-sensitive linkage. In the presence of a thiol-containing molecule such as GSH, the Dy will be dePEGylated through a disulfide exchange reaction, removing the molecular weight effect of the PEG, and allowing for the detection of GSH by MRI. This new MRI contrast agent could provide insight into the progression and diagnosis of oxidative stress pathologies associated with GSH."],"dc:description.degree":["M.S."],"dc:format.extent":["483651 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/10432"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Master of Science in Bioengineering"],"dc:relation.orgunit":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["a5c9fe8c-5d03-4de6-a761-459fb2af0dea"],"dc:subject":["MRI","Contrast agent","Glutathione","t1","t2"],"dc:title":["A New Magnetic Resonance Imaging Contrast Agent for the Detection of Glutathione"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:16:01Z"}