{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/11657"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/11657","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"The development of an in vitro flow simulation device to study the effects of arterial shear stress profiles on endotheilial cells","abstract":"Mechanical forces are important regulators of cell function in many tissues including, for example, bone and components of the cardiovascular system. The endothelial lining of blood vessels has been shown to respond in an atheroprotective manner to unidirectional, laminar flow-induced shear stress and in an atherogenic manner to oscillating and low levels of shear. We have developed a cone and plate shear apparatus to simulate fluid shear stress on endothelial cells in vitro. The significant feature of this apparatus is that, unlike other in vitro flow systems, it accurately produces varying levels of shear stress, consistent with those created in vivo during the cardiac cycle. Flow characteristics of this system were verified by computational fluid dynamics (CFD) and laser Doppler velocimetry (LDV). Cellular responses were monitored by cell morphology and protein expression. These responses are consistent with in vivo responses as well as previous work using other in vitro flow systems.","abstract_html":"Mechanical forces are important regulators of cell function in many tissues including, for example, bone and components of the cardiovascular system. The endothelial lining of blood vessels has been shown to respond in an atheroprotective manner to unidirectional, laminar flow-induced shear stress and in an atherogenic manner to oscillating and low levels of shear. We have developed a cone and plate shear apparatus to simulate fluid shear stress on endothelial cells in vitro. The significant feature of this apparatus is that, unlike other in vitro flow systems, it accurately produces varying levels of shear stress, consistent with those created in vivo during the cardiac cycle. Flow characteristics of this system were verified by computational fluid dynamics (CFD) and laser Doppler velocimetry (LDV). Cellular responses were monitored by cell morphology and protein expression. These responses are consistent with in vivo responses as well as previous work using other in vitro flow systems.","abstract_has_math":false,"creators":["Coleman, Sarah Elizabeth"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Biomedical Engineering","school":null,"contributors":[],"advisors":["Jo, Hanjoong"],"committee_chairs":[],"committee_members":["Yoganathan, Ajit P.","Giddens, Don P.","Taylor, W. Robert"],"year":2005,"date_issued":"2005-07-13","date_published":"2005-07-13","updated_at":"2026-11-19T06:08:04Z","subjects":["Endothelial cells","Flow simulation","Atherosclerosis","Laminar flow","Shear stress"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/11657","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/11657","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F11657","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jo, Hanjoong"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Yoganathan, Ajit P.","Giddens, Don P.","Taylor, W. Robert"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Coleman, Sarah Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-09-01T19:53:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-09-01T19:53:51Z"]},{"key":"dc:date.issued","label":"Date","values":["2005-07-13"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["7eb8fb49-de34-4fc6-aea8-80b31a2a2be8"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Endothelial cells","Flow simulation","Atherosclerosis","Laminar flow","Shear stress"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/11657"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Mechanical forces are important regulators of cell function in many tissues including, for example, bone and components of the cardiovascular system. The endothelial lining of blood vessels has been shown to respond in an atheroprotective manner to unidirectional, laminar flow-induced shear stress and in an atherogenic manner to oscillating and low levels of shear. We have developed a cone and plate shear apparatus to simulate fluid shear stress on endothelial cells in vitro. The significant feature of this apparatus is that, unlike other in vitro flow systems, it accurately produces varying levels of shear stress, consistent with those created in vivo during the cardiac cycle. Flow characteristics of this system were verified by computational fluid dynamics (CFD) and laser Doppler velocimetry (LDV). Cellular responses were monitored by cell morphology and protein expression. These responses are consistent with in vivo responses as well as previous work using other in vitro flow systems."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["2842117 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The development of an in vitro flow simulation device to study the effects of arterial shear stress profiles on endotheilial cells"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jo, Hanjoong"],"dc:contributor.committeemember":["Yoganathan, Ajit P.","Giddens, Don P.","Taylor, W. Robert"],"dc:contributor.department":["Biomedical Engineering"],"dc:contributor.other":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"],"dc:creator":["Coleman, Sarah Elizabeth"],"dc:date.accessioned":["2006-09-01T19:53:51Z"],"dc:date.available":["2006-09-01T19:53:51Z"],"dc:date.issued":["2005-07-13"],"dc:description.abstract":["Mechanical forces are important regulators of cell function in many tissues including, for example, bone and components of the cardiovascular system. The endothelial lining of blood vessels has been shown to respond in an atheroprotective manner to unidirectional, laminar flow-induced shear stress and in an atherogenic manner to oscillating and low levels of shear. We have developed a cone and plate shear apparatus to simulate fluid shear stress on endothelial cells in vitro. The significant feature of this apparatus is that, unlike other in vitro flow systems, it accurately produces varying levels of shear stress, consistent with those created in vivo during the cardiac cycle. Flow characteristics of this system were verified by computational fluid dynamics (CFD) and laser Doppler velocimetry (LDV). Cellular responses were monitored by cell morphology and protein expression. These responses are consistent with in vivo responses as well as previous work using other in vitro flow systems."],"dc:description.degree":["M.S."],"dc:format.extent":["2842117 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/11657"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["7eb8fb49-de34-4fc6-aea8-80b31a2a2be8"],"dc:relation.ispartofseries":["Master of Science in Biomedical Engineering"],"dc:relation.orgunit":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"],"dc:subject":["Endothelial cells","Flow simulation","Atherosclerosis","Laminar flow","Shear stress"],"dc:title":["The development of an in vitro flow simulation device to study the effects of arterial shear stress profiles on endotheilial cells"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T06:08:04Z"}